Analysis of particulate exposure during continuous drug infusion in critically ill adult patients: a preliminary proof-of-concept in vitro study

BACKGROUND: In critically ill patients, drug incompatibilities frequently occur because of the number of drugs to be administered through a limited number of infusion lines. These are among the main causes of particulate contamination. However, little data is available to quantify particle exposure...

Descripción completa

Detalles Bibliográficos
Autores principales: Benlabed, Malik, Martin Mena, Anthony, Gaudy, Romain, Perez, Maxime, Genay, Stéphanie, Hecq, Jean-Daniel, Odou, Pascal, Lebuffe, Gilles, Décaudin, Bertrand
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6179977/
https://www.ncbi.nlm.nih.gov/pubmed/30306347
http://dx.doi.org/10.1186/s40635-018-0205-2
Descripción
Sumario:BACKGROUND: In critically ill patients, drug incompatibilities frequently occur because of the number of drugs to be administered through a limited number of infusion lines. These are among the main causes of particulate contamination. However, little data is available to quantify particle exposure during simultaneous IV-drug infusion. The objective of this study was to evaluate the particulate matter potentially administered to critically ill patients. METHODS: The particulate matter (between 1 μm and 30 mm) of infused therapies used in ICUs for patients suffering from either septic shock or acute respiratory distress syndrome was measured in vitro over 6 h using a dynamic image analysis device, so that both overall particulate contamination and particle sizes could be determined. Data is presented according to the recommendations of the European Pharmacopoeia (≥ 10 and 25 μm). RESULTS: For the six experimental procedures (continuous infusion of norepinephrine, midazolam, sufentanil, heparin, 5% glucose, binary parenteral nutrition and discontinuous administrations of omeprazole, piperacillin/tazobactam and fluconazole), the overall number of particles over the 6-h infusion period was 8256 [5013; 15,044]. The collected values for the number of particles ≥ 10 and 25 μm were 281 [118; 526] and 19 [7; 96] respectively. Our results showed that discontinuous administrations of drugs led to disturbances in particulate contamination. CONCLUSIONS: This work indicates the amount of particulate matter potentially administered to critically ill adult patients. Particulate contamination appears lower than previous measurements performed during multidrug IV therapies in children.