Cargando…

Prosthetic rehabilitation of resected orbit in a case of mucormycosis

The design of orbital prosthesis to rehabilitate patients with orbital exenteration depends on the underlying clinical condition, material chosen for prosthesis, method of retention of the prosthesis, and and preference of the patient. Rehabilitation of a patient with orbital exenteration due to muc...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaur, Harsimran, Nanda, Aditi, Verma, Mahesh, Mutneja, Parul, Koli, Dheeraj, Bhardwaj, Smiti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6180739/
https://www.ncbi.nlm.nih.gov/pubmed/30449965
http://dx.doi.org/10.4103/jips.jips_53_18
_version_ 1783362270846255104
author Kaur, Harsimran
Nanda, Aditi
Verma, Mahesh
Mutneja, Parul
Koli, Dheeraj
Bhardwaj, Smiti
author_facet Kaur, Harsimran
Nanda, Aditi
Verma, Mahesh
Mutneja, Parul
Koli, Dheeraj
Bhardwaj, Smiti
author_sort Kaur, Harsimran
collection PubMed
description The design of orbital prosthesis to rehabilitate patients with orbital exenteration depends on the underlying clinical condition, material chosen for prosthesis, method of retention of the prosthesis, and and preference of the patient. Rehabilitation of a patient with orbital exenteration due to mucormycosis has been described by fabricating a prosthesis that used polymethyl methacrylate (to fabricate a conformer) and silicone material (to fabricate prosthetic superstructure). The two-component prosthesis was designed to attain dual mechanical retention using an anatomic undercut (conformer) and manually created mechanical undercut (prosthetic superstructure). The objective was to maintain the biological health of the underlying postsurgical tissue, longevity of the prosthesis, optimal esthetics, and adequate retention.
format Online
Article
Text
id pubmed-6180739
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-61807392019-10-01 Prosthetic rehabilitation of resected orbit in a case of mucormycosis Kaur, Harsimran Nanda, Aditi Verma, Mahesh Mutneja, Parul Koli, Dheeraj Bhardwaj, Smiti J Indian Prosthodont Soc Case Report The design of orbital prosthesis to rehabilitate patients with orbital exenteration depends on the underlying clinical condition, material chosen for prosthesis, method of retention of the prosthesis, and and preference of the patient. Rehabilitation of a patient with orbital exenteration due to mucormycosis has been described by fabricating a prosthesis that used polymethyl methacrylate (to fabricate a conformer) and silicone material (to fabricate prosthetic superstructure). The two-component prosthesis was designed to attain dual mechanical retention using an anatomic undercut (conformer) and manually created mechanical undercut (prosthetic superstructure). The objective was to maintain the biological health of the underlying postsurgical tissue, longevity of the prosthesis, optimal esthetics, and adequate retention. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6180739/ /pubmed/30449965 http://dx.doi.org/10.4103/jips.jips_53_18 Text en Copyright: © 2018 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Case Report
Kaur, Harsimran
Nanda, Aditi
Verma, Mahesh
Mutneja, Parul
Koli, Dheeraj
Bhardwaj, Smiti
Prosthetic rehabilitation of resected orbit in a case of mucormycosis
title Prosthetic rehabilitation of resected orbit in a case of mucormycosis
title_full Prosthetic rehabilitation of resected orbit in a case of mucormycosis
title_fullStr Prosthetic rehabilitation of resected orbit in a case of mucormycosis
title_full_unstemmed Prosthetic rehabilitation of resected orbit in a case of mucormycosis
title_short Prosthetic rehabilitation of resected orbit in a case of mucormycosis
title_sort prosthetic rehabilitation of resected orbit in a case of mucormycosis
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6180739/
https://www.ncbi.nlm.nih.gov/pubmed/30449965
http://dx.doi.org/10.4103/jips.jips_53_18
work_keys_str_mv AT kaurharsimran prostheticrehabilitationofresectedorbitinacaseofmucormycosis
AT nandaaditi prostheticrehabilitationofresectedorbitinacaseofmucormycosis
AT vermamahesh prostheticrehabilitationofresectedorbitinacaseofmucormycosis
AT mutnejaparul prostheticrehabilitationofresectedorbitinacaseofmucormycosis
AT kolidheeraj prostheticrehabilitationofresectedorbitinacaseofmucormycosis
AT bhardwajsmiti prostheticrehabilitationofresectedorbitinacaseofmucormycosis