Cargando…

Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient

We present a case report of an anticoagulated 78-year old man presenting a pulmonary artery pseudoaneurysm following Swan-Ganz catheter deployment after an aortic valve and aortic root replacement. Diagnosis was established by cone beam CT angiography and catheter angiographyand embolisation was ach...

Descripción completa

Detalles Bibliográficos
Autores principales: Ierardi, A M, Xhepa, G, Musazzi, A M, De Chiara, M, Beghi, C, Carrafiello, G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Institute of Radiology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6180823/
https://www.ncbi.nlm.nih.gov/pubmed/30363577
http://dx.doi.org/10.1259/bjrcr.20150064
_version_ 1783362290498666496
author Ierardi, A M
Xhepa, G
Musazzi, A M
De Chiara, M
Beghi, C
Carrafiello, G
author_facet Ierardi, A M
Xhepa, G
Musazzi, A M
De Chiara, M
Beghi, C
Carrafiello, G
author_sort Ierardi, A M
collection PubMed
description We present a case report of an anticoagulated 78-year old man presenting a pulmonary artery pseudoaneurysm following Swan-Ganz catheter deployment after an aortic valve and aortic root replacement. Diagnosis was established by cone beam CT angiography and catheter angiographyand embolisation was achieved via a combination of plug and glue. This case emphasises the importance of endovascular techniques in the management of iatrogenic pulmonary pseudoaneurysms and shows the benefit of using highly hemostatic polymeric agent in anticoagulated patients to obtain a rapid and effective occlusion.
format Online
Article
Text
id pubmed-6180823
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The British Institute of Radiology
record_format MEDLINE/PubMed
spelling pubmed-61808232018-10-25 Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient Ierardi, A M Xhepa, G Musazzi, A M De Chiara, M Beghi, C Carrafiello, G BJR Case Rep Case Report We present a case report of an anticoagulated 78-year old man presenting a pulmonary artery pseudoaneurysm following Swan-Ganz catheter deployment after an aortic valve and aortic root replacement. Diagnosis was established by cone beam CT angiography and catheter angiographyand embolisation was achieved via a combination of plug and glue. This case emphasises the importance of endovascular techniques in the management of iatrogenic pulmonary pseudoaneurysms and shows the benefit of using highly hemostatic polymeric agent in anticoagulated patients to obtain a rapid and effective occlusion. The British Institute of Radiology 2015-07-29 /pmc/articles/PMC6180823/ /pubmed/30363577 http://dx.doi.org/10.1259/bjrcr.20150064 Text en © 2015 The Authors. Published by the British Institute of Radiology http://creativecommons.org/licenses/by/4.0/ This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.
spellingShingle Case Report
Ierardi, A M
Xhepa, G
Musazzi, A M
De Chiara, M
Beghi, C
Carrafiello, G
Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient
title Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient
title_full Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient
title_fullStr Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient
title_full_unstemmed Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient
title_short Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient
title_sort endovascular treatment of a pulmonary artery pseudoaneurysm caused by swan-ganz catheter deployment in an anticoagulated patient
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6180823/
https://www.ncbi.nlm.nih.gov/pubmed/30363577
http://dx.doi.org/10.1259/bjrcr.20150064
work_keys_str_mv AT ierardiam endovasculartreatmentofapulmonaryarterypseudoaneurysmcausedbyswanganzcatheterdeploymentinananticoagulatedpatient
AT xhepag endovasculartreatmentofapulmonaryarterypseudoaneurysmcausedbyswanganzcatheterdeploymentinananticoagulatedpatient
AT musazziam endovasculartreatmentofapulmonaryarterypseudoaneurysmcausedbyswanganzcatheterdeploymentinananticoagulatedpatient
AT dechiaram endovasculartreatmentofapulmonaryarterypseudoaneurysmcausedbyswanganzcatheterdeploymentinananticoagulatedpatient
AT beghic endovasculartreatmentofapulmonaryarterypseudoaneurysmcausedbyswanganzcatheterdeploymentinananticoagulatedpatient
AT carrafiellog endovasculartreatmentofapulmonaryarterypseudoaneurysmcausedbyswanganzcatheterdeploymentinananticoagulatedpatient