Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses

PURPOSE: The aim of this study was to show the potential applicability of optical coherence tomography angiography (OCTA) for the evaluation of the peripheral fitting of fully scleral contact lenses. METHODS: A pilot study was proposed fitting three different scleral contact lenses (Irregular Cornea...

Descripción completa

Detalles Bibliográficos
Autores principales: Gimenez-Sanchis, Imma, Palacios-Carmen, Beatriz, García-Garrigós, Angel, Cantó-Vañó, Javier, Pérez-Ortega, Antonio J, Piñero, David P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6181809/
https://www.ncbi.nlm.nih.gov/pubmed/30319301
http://dx.doi.org/10.2147/OPTO.S164454
_version_ 1783362452860174336
author Gimenez-Sanchis, Imma
Palacios-Carmen, Beatriz
García-Garrigós, Angel
Cantó-Vañó, Javier
Pérez-Ortega, Antonio J
Piñero, David P
author_facet Gimenez-Sanchis, Imma
Palacios-Carmen, Beatriz
García-Garrigós, Angel
Cantó-Vañó, Javier
Pérez-Ortega, Antonio J
Piñero, David P
author_sort Gimenez-Sanchis, Imma
collection PubMed
description PURPOSE: The aim of this study was to show the potential applicability of optical coherence tomography angiography (OCTA) for the evaluation of the peripheral fitting of fully scleral contact lenses. METHODS: A pilot study was proposed fitting three different scleral contact lenses (Irregular Corneal Design [ICD]) with different sagittal heights (4200, 4800, and 5600 mm) in a healthy volunteer of 27 years old. We evaluated by means of optical coherence tomography (OCT, DRI Triton) the apical clearance achieved with each of the three lenses fitted. The impact over scleral flow was assessed with the OCTA module of the same device. RESULTS: The apical clearance was 310, 901, and 1680 µm with the scleral lenses of sagittal heights 4200, 4800, and 5600 µm, respectively. With OCTA, we evaluated the impact of the lens bearing on the conjunctival vascular flow, observing an area of vascular interruption of 0, 25, and 75% with the lenses of 4200, 4800, and 5600 µm of sagittal heights, respectively. The vascular interruption was induced in the perilimbar area, suggesting the need of readjusting the limbal clearance zone of the lens. CONCLUSION: Fully scleral contact lens fitting may be optimized with the use of OCTA, allowing the practitioner to perform the fitting with better control of the peripheral bearing of the lens on the conjunctival tissue, assessing the impact on vascular structures. This potential use of OCTA must be investigated further in future studies including large samples of eyes.
format Online
Article
Text
id pubmed-6181809
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-61818092018-10-12 Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses Gimenez-Sanchis, Imma Palacios-Carmen, Beatriz García-Garrigós, Angel Cantó-Vañó, Javier Pérez-Ortega, Antonio J Piñero, David P Clin Optom (Auckl) Rapid Communication PURPOSE: The aim of this study was to show the potential applicability of optical coherence tomography angiography (OCTA) for the evaluation of the peripheral fitting of fully scleral contact lenses. METHODS: A pilot study was proposed fitting three different scleral contact lenses (Irregular Corneal Design [ICD]) with different sagittal heights (4200, 4800, and 5600 mm) in a healthy volunteer of 27 years old. We evaluated by means of optical coherence tomography (OCT, DRI Triton) the apical clearance achieved with each of the three lenses fitted. The impact over scleral flow was assessed with the OCTA module of the same device. RESULTS: The apical clearance was 310, 901, and 1680 µm with the scleral lenses of sagittal heights 4200, 4800, and 5600 µm, respectively. With OCTA, we evaluated the impact of the lens bearing on the conjunctival vascular flow, observing an area of vascular interruption of 0, 25, and 75% with the lenses of 4200, 4800, and 5600 µm of sagittal heights, respectively. The vascular interruption was induced in the perilimbar area, suggesting the need of readjusting the limbal clearance zone of the lens. CONCLUSION: Fully scleral contact lens fitting may be optimized with the use of OCTA, allowing the practitioner to perform the fitting with better control of the peripheral bearing of the lens on the conjunctival tissue, assessing the impact on vascular structures. This potential use of OCTA must be investigated further in future studies including large samples of eyes. Dove Medical Press 2018-09-04 /pmc/articles/PMC6181809/ /pubmed/30319301 http://dx.doi.org/10.2147/OPTO.S164454 Text en © 2018 Gimenez-Sanchis et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Rapid Communication
Gimenez-Sanchis, Imma
Palacios-Carmen, Beatriz
García-Garrigós, Angel
Cantó-Vañó, Javier
Pérez-Ortega, Antonio J
Piñero, David P
Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses
title Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses
title_full Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses
title_fullStr Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses
title_full_unstemmed Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses
title_short Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses
title_sort anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses
topic Rapid Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6181809/
https://www.ncbi.nlm.nih.gov/pubmed/30319301
http://dx.doi.org/10.2147/OPTO.S164454
work_keys_str_mv AT gimenezsanchisimma anteriorsegmentopticalcoherencetomographyangiographytoevaluatetheperipheralfittingofscleralcontactlenses
AT palacioscarmenbeatriz anteriorsegmentopticalcoherencetomographyangiographytoevaluatetheperipheralfittingofscleralcontactlenses
AT garciagarrigosangel anteriorsegmentopticalcoherencetomographyangiographytoevaluatetheperipheralfittingofscleralcontactlenses
AT cantovanojavier anteriorsegmentopticalcoherencetomographyangiographytoevaluatetheperipheralfittingofscleralcontactlenses
AT perezortegaantonioj anteriorsegmentopticalcoherencetomographyangiographytoevaluatetheperipheralfittingofscleralcontactlenses
AT pinerodavidp anteriorsegmentopticalcoherencetomographyangiographytoevaluatetheperipheralfittingofscleralcontactlenses