Cargando…
Report of Massive Bleed after Chest-drain Insertion in a Case of Job's (hyper-IgE) Syndrome
Chest-drain insertion is considered to be a benign procedure. A 6-year-old girl who is a known case of hyper-IgE/Job's syndrome presented to us following three episodes of fresh bleed following chest-drain insertion for the left lung abscess. The site of bleed was localized to be the ruptured p...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6182952/ https://www.ncbi.nlm.nih.gov/pubmed/30443121 http://dx.doi.org/10.4103/jiaps.JIAPS_72_17 |
_version_ | 1783362675876560896 |
---|---|
author | Goel, Prabudh Jain, Vishesh Kumar, Sanjeev Sharma, Sanjiv Bajpai, Minu |
author_facet | Goel, Prabudh Jain, Vishesh Kumar, Sanjeev Sharma, Sanjiv Bajpai, Minu |
author_sort | Goel, Prabudh |
collection | PubMed |
description | Chest-drain insertion is considered to be a benign procedure. A 6-year-old girl who is a known case of hyper-IgE/Job's syndrome presented to us following three episodes of fresh bleed following chest-drain insertion for the left lung abscess. The site of bleed was localized to be the ruptured pseudoaneurysm of the anterior segmental branch of the left pulmonary artery. For successful management, various pitfalls and gray areas have been highlighted: (a) the procedure of chest-drain insertion has a potential for many complications some of which may be life-threatening, (b) the importance of proper history taking and a complete evaluation of all patients before surgical intervention, (c) role of ultrasound-guided chest-drain insertion, and (d) the importance of lateral and pragmatic approach with multidisciplinary involvement in such unusual and challenging cases cannot be overemphasized. |
format | Online Article Text |
id | pubmed-6182952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-61829522018-11-15 Report of Massive Bleed after Chest-drain Insertion in a Case of Job's (hyper-IgE) Syndrome Goel, Prabudh Jain, Vishesh Kumar, Sanjeev Sharma, Sanjiv Bajpai, Minu J Indian Assoc Pediatr Surg Case Report Chest-drain insertion is considered to be a benign procedure. A 6-year-old girl who is a known case of hyper-IgE/Job's syndrome presented to us following three episodes of fresh bleed following chest-drain insertion for the left lung abscess. The site of bleed was localized to be the ruptured pseudoaneurysm of the anterior segmental branch of the left pulmonary artery. For successful management, various pitfalls and gray areas have been highlighted: (a) the procedure of chest-drain insertion has a potential for many complications some of which may be life-threatening, (b) the importance of proper history taking and a complete evaluation of all patients before surgical intervention, (c) role of ultrasound-guided chest-drain insertion, and (d) the importance of lateral and pragmatic approach with multidisciplinary involvement in such unusual and challenging cases cannot be overemphasized. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6182952/ /pubmed/30443121 http://dx.doi.org/10.4103/jiaps.JIAPS_72_17 Text en Copyright: © 2018 Journal of Indian Association of Pediatric Surgeons http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Goel, Prabudh Jain, Vishesh Kumar, Sanjeev Sharma, Sanjiv Bajpai, Minu Report of Massive Bleed after Chest-drain Insertion in a Case of Job's (hyper-IgE) Syndrome |
title | Report of Massive Bleed after Chest-drain Insertion in a Case of Job's (hyper-IgE) Syndrome |
title_full | Report of Massive Bleed after Chest-drain Insertion in a Case of Job's (hyper-IgE) Syndrome |
title_fullStr | Report of Massive Bleed after Chest-drain Insertion in a Case of Job's (hyper-IgE) Syndrome |
title_full_unstemmed | Report of Massive Bleed after Chest-drain Insertion in a Case of Job's (hyper-IgE) Syndrome |
title_short | Report of Massive Bleed after Chest-drain Insertion in a Case of Job's (hyper-IgE) Syndrome |
title_sort | report of massive bleed after chest-drain insertion in a case of job's (hyper-ige) syndrome |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6182952/ https://www.ncbi.nlm.nih.gov/pubmed/30443121 http://dx.doi.org/10.4103/jiaps.JIAPS_72_17 |
work_keys_str_mv | AT goelprabudh reportofmassivebleedafterchestdraininsertioninacaseofjobshyperigesyndrome AT jainvishesh reportofmassivebleedafterchestdraininsertioninacaseofjobshyperigesyndrome AT kumarsanjeev reportofmassivebleedafterchestdraininsertioninacaseofjobshyperigesyndrome AT sharmasanjiv reportofmassivebleedafterchestdraininsertioninacaseofjobshyperigesyndrome AT bajpaiminu reportofmassivebleedafterchestdraininsertioninacaseofjobshyperigesyndrome |