Cargando…
Repetitive transcranial magnetic stimulation for the treatment of Alzheimer's disease: A systematic review and meta-analysis of randomized controlled trials
BACKGROUND: Several studies have demonstrated that repetitive transcranial magnetic stimulation (rTMS) may have a beneficial effect in Alzheimer’s disease (AD). Nevertheless, the clinical benefit of rTMS for AD remains inconclusive. OBJECTIVE: This systematic review and meta-analysis aimed to evalua...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6185837/ https://www.ncbi.nlm.nih.gov/pubmed/30312319 http://dx.doi.org/10.1371/journal.pone.0205704 |
Sumario: | BACKGROUND: Several studies have demonstrated that repetitive transcranial magnetic stimulation (rTMS) may have a beneficial effect in Alzheimer’s disease (AD). Nevertheless, the clinical benefit of rTMS for AD remains inconclusive. OBJECTIVE: This systematic review and meta-analysis aimed to evaluate the efficacy and safety of rTMS in AD. METHODS: We searched PubMed, Embase and Cochrane for randomized controlled trials (RCTs) of rTMS for AD. We calculated pooled estimates of mean difference (MD) with 95% confidence intervals (CI). The protocol was registered at International Prospective Register of Systematic Reviews (PROSPERO) (number CRD42018089990). RESULTS: Five RCTs involving 148 participants were included in this review. Compared with sham stimulation, high-frequency rTMS led to a significant improvement in cognition as measured by ADAS-cog (MD = -3.65, 95% CI -5.82 to -1.48, p = 0.001), but not MMSE (MD = 0.49, 95% CI -1.45 to 2.42, p = 0.62). High-frequency rTMS also improved the global impression in comparison to the placebo (MD = -0.79, 95% CI -1.24 to -0.34, p = 0.0006). There was no significant difference in mood (MD = -1.36, 95% CI -3.93 to 1.21, p = 0.30) and functional performance (MD = 0.59, 95% CI -1.21 to 2.38, p = 0.52) between high-frequency rTMS and sham groups. Only one trial included low-frequency rTMS reported no significant improvement in cognition, mood and functional performance. Few mild adverse events were observed in both the rTMS and sham groups. CONCLUSIONS: RTMS is relatively well tolerated, with some promise for cognitive improvement and global impression in patients with AD. Our findings also indicate the variability between ADAS-cog and MMSE in evaluating global cognitive impairment. |
---|