Cargando…

Force measurement metrics for simulated elbow arthroscopy training

BACKGROUND: Elbow arthroscopy is a difficult surgical technique. Objective metrics can be used to improve safe and effective training in elbow arthroscopy. Force exerted on the elbow tissue during arthroscopy can be a measure of safe tissue manipulation. The purpose of this study was to determine th...

Descripción completa

Detalles Bibliográficos
Autores principales: Hilgersom, Nick F. J., Horeman-Franse, Tim, Bleys, Ronald L. A. W., Eygendaal, Denise, van den Bekerom, Michel P. J., Tuijthof, Gabriëlle J. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6185876/
https://www.ncbi.nlm.nih.gov/pubmed/30315425
http://dx.doi.org/10.1186/s40634-018-0157-1
_version_ 1783362758886031360
author Hilgersom, Nick F. J.
Horeman-Franse, Tim
Bleys, Ronald L. A. W.
Eygendaal, Denise
van den Bekerom, Michel P. J.
Tuijthof, Gabriëlle J. M.
author_facet Hilgersom, Nick F. J.
Horeman-Franse, Tim
Bleys, Ronald L. A. W.
Eygendaal, Denise
van den Bekerom, Michel P. J.
Tuijthof, Gabriëlle J. M.
author_sort Hilgersom, Nick F. J.
collection PubMed
description BACKGROUND: Elbow arthroscopy is a difficult surgical technique. Objective metrics can be used to improve safe and effective training in elbow arthroscopy. Force exerted on the elbow tissue during arthroscopy can be a measure of safe tissue manipulation. The purpose of this study was to determine the force magnitude and force direction used by experts during arthroscopic elbow navigation in cadaveric specimens and assess their applicability in elbow arthroscopy training. METHODS: Two cadaveric elbows were mounted on a Force Measurement Table (FMT) that allowed 3-dimensional measurements (x-, y-, and z-plane) of the forces exerted on the elbow. Five experts in elbow arthroscopy performed arthroscopic navigation once in each of two cadaveric elbows, navigating through the posterior, posterolateral and anterior compartment in a standardized fashion with visualization of three to four anatomic landmarks per compartment. The total absolute force (F(abs)) and force direction exerted (α and β) on the elbow during arthroscopy were recorded. α being the angle in the horizontal plane and β being the angle in the vertical plane. The 10th–90th percentiles of the data were used to set threshold levels for training. RESULTS: The median F(abs) was 24 N (19 N – 30 N), 27 N (20 N – 33 N) and 29 N (23 N – 32 N) for the posterior, posterolateral and anterior compartment, respectively. The median α was - 29° (- 55° – 5°), - 23° (- 56° – -1°) and 4° (- 22° – -18°) for the posterior, posterolateral and anterior compartment, respectively. The median β was - 71° (- 80° – -65°), - 76° (- 86° – -69°) and - 75° (- 81° – -71°) for the posterior, posterolateral and anterior compartment, respectively. CONCLUSION: Expert data on force magnitude and force direction exerted on the elbow during arthroscopic navigation in cadaveric specimens were collected. The proposed maximum allowable force of 30 N (smallest 90th percentile of F(abs)) exerted on the elbow tissue, and the 10th–90th percentile range of the force directions (α and β) for each compartment may be used to provide objective feedback during arthroscopic skills training.
format Online
Article
Text
id pubmed-6185876
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-61858762018-10-18 Force measurement metrics for simulated elbow arthroscopy training Hilgersom, Nick F. J. Horeman-Franse, Tim Bleys, Ronald L. A. W. Eygendaal, Denise van den Bekerom, Michel P. J. Tuijthof, Gabriëlle J. M. J Exp Orthop Research BACKGROUND: Elbow arthroscopy is a difficult surgical technique. Objective metrics can be used to improve safe and effective training in elbow arthroscopy. Force exerted on the elbow tissue during arthroscopy can be a measure of safe tissue manipulation. The purpose of this study was to determine the force magnitude and force direction used by experts during arthroscopic elbow navigation in cadaveric specimens and assess their applicability in elbow arthroscopy training. METHODS: Two cadaveric elbows were mounted on a Force Measurement Table (FMT) that allowed 3-dimensional measurements (x-, y-, and z-plane) of the forces exerted on the elbow. Five experts in elbow arthroscopy performed arthroscopic navigation once in each of two cadaveric elbows, navigating through the posterior, posterolateral and anterior compartment in a standardized fashion with visualization of three to four anatomic landmarks per compartment. The total absolute force (F(abs)) and force direction exerted (α and β) on the elbow during arthroscopy were recorded. α being the angle in the horizontal plane and β being the angle in the vertical plane. The 10th–90th percentiles of the data were used to set threshold levels for training. RESULTS: The median F(abs) was 24 N (19 N – 30 N), 27 N (20 N – 33 N) and 29 N (23 N – 32 N) for the posterior, posterolateral and anterior compartment, respectively. The median α was - 29° (- 55° – 5°), - 23° (- 56° – -1°) and 4° (- 22° – -18°) for the posterior, posterolateral and anterior compartment, respectively. The median β was - 71° (- 80° – -65°), - 76° (- 86° – -69°) and - 75° (- 81° – -71°) for the posterior, posterolateral and anterior compartment, respectively. CONCLUSION: Expert data on force magnitude and force direction exerted on the elbow during arthroscopic navigation in cadaveric specimens were collected. The proposed maximum allowable force of 30 N (smallest 90th percentile of F(abs)) exerted on the elbow tissue, and the 10th–90th percentile range of the force directions (α and β) for each compartment may be used to provide objective feedback during arthroscopic skills training. Springer Berlin Heidelberg 2018-10-11 /pmc/articles/PMC6185876/ /pubmed/30315425 http://dx.doi.org/10.1186/s40634-018-0157-1 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Hilgersom, Nick F. J.
Horeman-Franse, Tim
Bleys, Ronald L. A. W.
Eygendaal, Denise
van den Bekerom, Michel P. J.
Tuijthof, Gabriëlle J. M.
Force measurement metrics for simulated elbow arthroscopy training
title Force measurement metrics for simulated elbow arthroscopy training
title_full Force measurement metrics for simulated elbow arthroscopy training
title_fullStr Force measurement metrics for simulated elbow arthroscopy training
title_full_unstemmed Force measurement metrics for simulated elbow arthroscopy training
title_short Force measurement metrics for simulated elbow arthroscopy training
title_sort force measurement metrics for simulated elbow arthroscopy training
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6185876/
https://www.ncbi.nlm.nih.gov/pubmed/30315425
http://dx.doi.org/10.1186/s40634-018-0157-1
work_keys_str_mv AT hilgersomnickfj forcemeasurementmetricsforsimulatedelbowarthroscopytraining
AT horemanfransetim forcemeasurementmetricsforsimulatedelbowarthroscopytraining
AT bleysronaldlaw forcemeasurementmetricsforsimulatedelbowarthroscopytraining
AT eygendaaldenise forcemeasurementmetricsforsimulatedelbowarthroscopytraining
AT vandenbekerommichelpj forcemeasurementmetricsforsimulatedelbowarthroscopytraining
AT tuijthofgabriellejm forcemeasurementmetricsforsimulatedelbowarthroscopytraining
AT forcemeasurementmetricsforsimulatedelbowarthroscopytraining