Cargando…

A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications

A linear non-resonant kinetic energy harvester for implantable devices is presented. The design contains a metal platform with permanent magnets, two stators with three-dimensional helical coils for increased power generation, ball bearings, and a polydimethylsiloxane (PDMS) package for biocompatibi...

Descripción completa

Detalles Bibliográficos
Autores principales: Beyaz, Mustafa İ., Baelhadj, Hacene C., Habibiabad, Sahar, Adhikari, Shyam S., Davoodi, Hossein, Badilita, Vlad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187287/
https://www.ncbi.nlm.nih.gov/pubmed/30424150
http://dx.doi.org/10.3390/mi9050217
_version_ 1783362992152248320
author Beyaz, Mustafa İ.
Baelhadj, Hacene C.
Habibiabad, Sahar
Adhikari, Shyam S.
Davoodi, Hossein
Badilita, Vlad
author_facet Beyaz, Mustafa İ.
Baelhadj, Hacene C.
Habibiabad, Sahar
Adhikari, Shyam S.
Davoodi, Hossein
Badilita, Vlad
author_sort Beyaz, Mustafa İ.
collection PubMed
description A linear non-resonant kinetic energy harvester for implantable devices is presented. The design contains a metal platform with permanent magnets, two stators with three-dimensional helical coils for increased power generation, ball bearings, and a polydimethylsiloxane (PDMS) package for biocompatibility. Mechanical excitation of this device within the body due to daily activities leads to a relative motion between the platform and stators, resulting in electromagnetic induction. Initial prototypes without packaging have been fabricated and characterized on a linear shaker. Dynamic tests showed that the friction force acting on the platform is on the order of 0.6 mN. The resistance and the inductance of the coils were measured to be 2.2 Ω and 0.4 µH, respectively. A peak open circuit voltage of 1.05 mV was generated per stator at a platform speed of 5.8 cm/s. Further development of this device offers potential for recharging the batteries of implantable biomedical devices within the body.
format Online
Article
Text
id pubmed-6187287
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61872872018-11-01 A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications Beyaz, Mustafa İ. Baelhadj, Hacene C. Habibiabad, Sahar Adhikari, Shyam S. Davoodi, Hossein Badilita, Vlad Micromachines (Basel) Article A linear non-resonant kinetic energy harvester for implantable devices is presented. The design contains a metal platform with permanent magnets, two stators with three-dimensional helical coils for increased power generation, ball bearings, and a polydimethylsiloxane (PDMS) package for biocompatibility. Mechanical excitation of this device within the body due to daily activities leads to a relative motion between the platform and stators, resulting in electromagnetic induction. Initial prototypes without packaging have been fabricated and characterized on a linear shaker. Dynamic tests showed that the friction force acting on the platform is on the order of 0.6 mN. The resistance and the inductance of the coils were measured to be 2.2 Ω and 0.4 µH, respectively. A peak open circuit voltage of 1.05 mV was generated per stator at a platform speed of 5.8 cm/s. Further development of this device offers potential for recharging the batteries of implantable biomedical devices within the body. MDPI 2018-05-05 /pmc/articles/PMC6187287/ /pubmed/30424150 http://dx.doi.org/10.3390/mi9050217 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Beyaz, Mustafa İ.
Baelhadj, Hacene C.
Habibiabad, Sahar
Adhikari, Shyam S.
Davoodi, Hossein
Badilita, Vlad
A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications
title A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications
title_full A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications
title_fullStr A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications
title_full_unstemmed A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications
title_short A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications
title_sort non-resonant kinetic energy harvester for bioimplantable applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187287/
https://www.ncbi.nlm.nih.gov/pubmed/30424150
http://dx.doi.org/10.3390/mi9050217
work_keys_str_mv AT beyazmustafai anonresonantkineticenergyharvesterforbioimplantableapplications
AT baelhadjhacenec anonresonantkineticenergyharvesterforbioimplantableapplications
AT habibiabadsahar anonresonantkineticenergyharvesterforbioimplantableapplications
AT adhikarishyams anonresonantkineticenergyharvesterforbioimplantableapplications
AT davoodihossein anonresonantkineticenergyharvesterforbioimplantableapplications
AT badilitavlad anonresonantkineticenergyharvesterforbioimplantableapplications
AT beyazmustafai nonresonantkineticenergyharvesterforbioimplantableapplications
AT baelhadjhacenec nonresonantkineticenergyharvesterforbioimplantableapplications
AT habibiabadsahar nonresonantkineticenergyharvesterforbioimplantableapplications
AT adhikarishyams nonresonantkineticenergyharvesterforbioimplantableapplications
AT davoodihossein nonresonantkineticenergyharvesterforbioimplantableapplications
AT badilitavlad nonresonantkineticenergyharvesterforbioimplantableapplications