A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications
A linear non-resonant kinetic energy harvester for implantable devices is presented. The design contains a metal platform with permanent magnets, two stators with three-dimensional helical coils for increased power generation, ball bearings, and a polydimethylsiloxane (PDMS) package for biocompatibi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187287/ https://www.ncbi.nlm.nih.gov/pubmed/30424150 http://dx.doi.org/10.3390/mi9050217 |
_version_ | 1783362992152248320 |
---|---|
author | Beyaz, Mustafa İ. Baelhadj, Hacene C. Habibiabad, Sahar Adhikari, Shyam S. Davoodi, Hossein Badilita, Vlad |
author_facet | Beyaz, Mustafa İ. Baelhadj, Hacene C. Habibiabad, Sahar Adhikari, Shyam S. Davoodi, Hossein Badilita, Vlad |
author_sort | Beyaz, Mustafa İ. |
collection | PubMed |
description | A linear non-resonant kinetic energy harvester for implantable devices is presented. The design contains a metal platform with permanent magnets, two stators with three-dimensional helical coils for increased power generation, ball bearings, and a polydimethylsiloxane (PDMS) package for biocompatibility. Mechanical excitation of this device within the body due to daily activities leads to a relative motion between the platform and stators, resulting in electromagnetic induction. Initial prototypes without packaging have been fabricated and characterized on a linear shaker. Dynamic tests showed that the friction force acting on the platform is on the order of 0.6 mN. The resistance and the inductance of the coils were measured to be 2.2 Ω and 0.4 µH, respectively. A peak open circuit voltage of 1.05 mV was generated per stator at a platform speed of 5.8 cm/s. Further development of this device offers potential for recharging the batteries of implantable biomedical devices within the body. |
format | Online Article Text |
id | pubmed-6187287 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61872872018-11-01 A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications Beyaz, Mustafa İ. Baelhadj, Hacene C. Habibiabad, Sahar Adhikari, Shyam S. Davoodi, Hossein Badilita, Vlad Micromachines (Basel) Article A linear non-resonant kinetic energy harvester for implantable devices is presented. The design contains a metal platform with permanent magnets, two stators with three-dimensional helical coils for increased power generation, ball bearings, and a polydimethylsiloxane (PDMS) package for biocompatibility. Mechanical excitation of this device within the body due to daily activities leads to a relative motion between the platform and stators, resulting in electromagnetic induction. Initial prototypes without packaging have been fabricated and characterized on a linear shaker. Dynamic tests showed that the friction force acting on the platform is on the order of 0.6 mN. The resistance and the inductance of the coils were measured to be 2.2 Ω and 0.4 µH, respectively. A peak open circuit voltage of 1.05 mV was generated per stator at a platform speed of 5.8 cm/s. Further development of this device offers potential for recharging the batteries of implantable biomedical devices within the body. MDPI 2018-05-05 /pmc/articles/PMC6187287/ /pubmed/30424150 http://dx.doi.org/10.3390/mi9050217 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Beyaz, Mustafa İ. Baelhadj, Hacene C. Habibiabad, Sahar Adhikari, Shyam S. Davoodi, Hossein Badilita, Vlad A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications |
title | A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications |
title_full | A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications |
title_fullStr | A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications |
title_full_unstemmed | A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications |
title_short | A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications |
title_sort | non-resonant kinetic energy harvester for bioimplantable applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187287/ https://www.ncbi.nlm.nih.gov/pubmed/30424150 http://dx.doi.org/10.3390/mi9050217 |
work_keys_str_mv | AT beyazmustafai anonresonantkineticenergyharvesterforbioimplantableapplications AT baelhadjhacenec anonresonantkineticenergyharvesterforbioimplantableapplications AT habibiabadsahar anonresonantkineticenergyharvesterforbioimplantableapplications AT adhikarishyams anonresonantkineticenergyharvesterforbioimplantableapplications AT davoodihossein anonresonantkineticenergyharvesterforbioimplantableapplications AT badilitavlad anonresonantkineticenergyharvesterforbioimplantableapplications AT beyazmustafai nonresonantkineticenergyharvesterforbioimplantableapplications AT baelhadjhacenec nonresonantkineticenergyharvesterforbioimplantableapplications AT habibiabadsahar nonresonantkineticenergyharvesterforbioimplantableapplications AT adhikarishyams nonresonantkineticenergyharvesterforbioimplantableapplications AT davoodihossein nonresonantkineticenergyharvesterforbioimplantableapplications AT badilitavlad nonresonantkineticenergyharvesterforbioimplantableapplications |