Cargando…

LED Optrode with Integrated Temperature Sensing for Optogenetics

In optogenetic studies, the brain is exposed to high-power light sources and inadequate power density or exposure time can cause cell damage from overheating (typically temperature increasing of 2 [Formula: see text] C). In order to overcome overheating issues in optogenetics, this paper presents a...

Descripción completa

Detalles Bibliográficos
Autores principales: Goncalves, S. Beatriz, Palha, José M., Fernandes, Helena C., Souto, Márcio R., Pimenta, Sara, Dong, Tao, Yang, Zhaochu, Ribeiro, João F., Correia, José H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187356/
https://www.ncbi.nlm.nih.gov/pubmed/30424406
http://dx.doi.org/10.3390/mi9090473
_version_ 1783363008317095936
author Goncalves, S. Beatriz
Palha, José M.
Fernandes, Helena C.
Souto, Márcio R.
Pimenta, Sara
Dong, Tao
Yang, Zhaochu
Ribeiro, João F.
Correia, José H.
author_facet Goncalves, S. Beatriz
Palha, José M.
Fernandes, Helena C.
Souto, Márcio R.
Pimenta, Sara
Dong, Tao
Yang, Zhaochu
Ribeiro, João F.
Correia, José H.
author_sort Goncalves, S. Beatriz
collection PubMed
description In optogenetic studies, the brain is exposed to high-power light sources and inadequate power density or exposure time can cause cell damage from overheating (typically temperature increasing of 2 [Formula: see text] C). In order to overcome overheating issues in optogenetics, this paper presents a neural tool capable of assessing tissue temperature over time, combined with the capability of electrical recording and optical stimulation. A silicon-based 8 mm long probe was manufactured to reach deep neural structures. The final proof-of-concept device comprises a double-sided function: on one side, an optrode with LED-based stimulation and platinum (Pt) recording points; and, on the opposite side, a Pt-based thin-film thermoresistance (RTD) for temperature assessing in the photostimulation site surroundings. Pt thin-films for tissue interface were chosen due to its biocompatibility and thermal linearity. A single-shaft probe is demonstrated for integration in a 3D probe array. A 3D probe array will reduce the distance between the thermal sensor and the heating source. Results show good recording and optical features, with average impedance magnitude of 371 k [Formula: see text] , at 1 kHz, and optical power of 1.2 mW·mm [Formula: see text] (at 470 nm), respectively. The manufactured RTD showed resolution of 0.2 [Formula: see text] C at 37 [Formula: see text] C (normal body temperature). Overall, the results show a device capable of meeting the requirements of a neural interface for recording/stimulating of neural activity and monitoring temperature profile of the photostimulation site surroundings, which suggests a promising tool for neuroscience research filed.
format Online
Article
Text
id pubmed-6187356
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61873562018-11-01 LED Optrode with Integrated Temperature Sensing for Optogenetics Goncalves, S. Beatriz Palha, José M. Fernandes, Helena C. Souto, Márcio R. Pimenta, Sara Dong, Tao Yang, Zhaochu Ribeiro, João F. Correia, José H. Micromachines (Basel) Article In optogenetic studies, the brain is exposed to high-power light sources and inadequate power density or exposure time can cause cell damage from overheating (typically temperature increasing of 2 [Formula: see text] C). In order to overcome overheating issues in optogenetics, this paper presents a neural tool capable of assessing tissue temperature over time, combined with the capability of electrical recording and optical stimulation. A silicon-based 8 mm long probe was manufactured to reach deep neural structures. The final proof-of-concept device comprises a double-sided function: on one side, an optrode with LED-based stimulation and platinum (Pt) recording points; and, on the opposite side, a Pt-based thin-film thermoresistance (RTD) for temperature assessing in the photostimulation site surroundings. Pt thin-films for tissue interface were chosen due to its biocompatibility and thermal linearity. A single-shaft probe is demonstrated for integration in a 3D probe array. A 3D probe array will reduce the distance between the thermal sensor and the heating source. Results show good recording and optical features, with average impedance magnitude of 371 k [Formula: see text] , at 1 kHz, and optical power of 1.2 mW·mm [Formula: see text] (at 470 nm), respectively. The manufactured RTD showed resolution of 0.2 [Formula: see text] C at 37 [Formula: see text] C (normal body temperature). Overall, the results show a device capable of meeting the requirements of a neural interface for recording/stimulating of neural activity and monitoring temperature profile of the photostimulation site surroundings, which suggests a promising tool for neuroscience research filed. MDPI 2018-09-17 /pmc/articles/PMC6187356/ /pubmed/30424406 http://dx.doi.org/10.3390/mi9090473 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Goncalves, S. Beatriz
Palha, José M.
Fernandes, Helena C.
Souto, Márcio R.
Pimenta, Sara
Dong, Tao
Yang, Zhaochu
Ribeiro, João F.
Correia, José H.
LED Optrode with Integrated Temperature Sensing for Optogenetics
title LED Optrode with Integrated Temperature Sensing for Optogenetics
title_full LED Optrode with Integrated Temperature Sensing for Optogenetics
title_fullStr LED Optrode with Integrated Temperature Sensing for Optogenetics
title_full_unstemmed LED Optrode with Integrated Temperature Sensing for Optogenetics
title_short LED Optrode with Integrated Temperature Sensing for Optogenetics
title_sort led optrode with integrated temperature sensing for optogenetics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187356/
https://www.ncbi.nlm.nih.gov/pubmed/30424406
http://dx.doi.org/10.3390/mi9090473
work_keys_str_mv AT goncalvessbeatriz ledoptrodewithintegratedtemperaturesensingforoptogenetics
AT palhajosem ledoptrodewithintegratedtemperaturesensingforoptogenetics
AT fernandeshelenac ledoptrodewithintegratedtemperaturesensingforoptogenetics
AT soutomarcior ledoptrodewithintegratedtemperaturesensingforoptogenetics
AT pimentasara ledoptrodewithintegratedtemperaturesensingforoptogenetics
AT dongtao ledoptrodewithintegratedtemperaturesensingforoptogenetics
AT yangzhaochu ledoptrodewithintegratedtemperaturesensingforoptogenetics
AT ribeirojoaof ledoptrodewithintegratedtemperaturesensingforoptogenetics
AT correiajoseh ledoptrodewithintegratedtemperaturesensingforoptogenetics