Development of an AVF Stenosis Assessment Tool for Hemodialysis Patients Using Robotic Ultrasound System

With the aging population and lifestyle changes, the number of hemodialysis (HD) patients increases year by year. The arteriovenous fistula (AVF) is the gold standard vascular access used to access the blood for HD treatment. Since the status of stenosis affects HD efficiency, current clinical pract...

Descripción completa

Detalles Bibliográficos
Autores principales: Du, Yi-Chun, Shih, Jheng-Bang, Wu, Ming-Jui, Chiou, Chung-Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187484/
https://www.ncbi.nlm.nih.gov/pubmed/30393327
http://dx.doi.org/10.3390/mi9020051
_version_ 1783363030201925632
author Du, Yi-Chun
Shih, Jheng-Bang
Wu, Ming-Jui
Chiou, Chung-Yi
author_facet Du, Yi-Chun
Shih, Jheng-Bang
Wu, Ming-Jui
Chiou, Chung-Yi
author_sort Du, Yi-Chun
collection PubMed
description With the aging population and lifestyle changes, the number of hemodialysis (HD) patients increases year by year. The arteriovenous fistula (AVF) is the gold standard vascular access used to access the blood for HD treatment. Since the status of stenosis affects HD efficiency, current clinical practices usually use a Doppler ultrasound imaging system to assess the parameters of the stenosis, such as the degree of stenosis (DOS). Unfortunately, this is a very time-consuming task. Furthermore, it is difficult to stably maintain the ultrasound probe for a prolonged period to give doctors clearer or reproducible images. In this study, a robotic ultrasound system (RUS) with ultrasound sequential imaging analysis was designed to evaluate the DOS of the AVF. The sequential imaging analysis was capable of image smoothing and vessel boundary detection. It enabled clinicians to mark the thickness of the plaque for further processing. Finally, the system was used to reconstruct 3D models of fistulas and calculated the DOS for clinical assessment. We also designed a pressure sensing module attached to the ultrasound probe to prevent the probe from coming loose, vibrating, and exerting abnormal pressure on the skin. In the phantom test, the results showed that the error of the DOS that was calculated by RUS was less than 3%. The results of clinical trials obtained from ten patients show that the error between the RUS and clinicians’ measurement was about 10% and had a highly linear correlation (R Square > 0.95). In addition, the reproducibility error was about 3% and could effectively save about 46% of the time during clinical examinations.
format Online
Article
Text
id pubmed-6187484
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61874842018-11-01 Development of an AVF Stenosis Assessment Tool for Hemodialysis Patients Using Robotic Ultrasound System Du, Yi-Chun Shih, Jheng-Bang Wu, Ming-Jui Chiou, Chung-Yi Micromachines (Basel) Article With the aging population and lifestyle changes, the number of hemodialysis (HD) patients increases year by year. The arteriovenous fistula (AVF) is the gold standard vascular access used to access the blood for HD treatment. Since the status of stenosis affects HD efficiency, current clinical practices usually use a Doppler ultrasound imaging system to assess the parameters of the stenosis, such as the degree of stenosis (DOS). Unfortunately, this is a very time-consuming task. Furthermore, it is difficult to stably maintain the ultrasound probe for a prolonged period to give doctors clearer or reproducible images. In this study, a robotic ultrasound system (RUS) with ultrasound sequential imaging analysis was designed to evaluate the DOS of the AVF. The sequential imaging analysis was capable of image smoothing and vessel boundary detection. It enabled clinicians to mark the thickness of the plaque for further processing. Finally, the system was used to reconstruct 3D models of fistulas and calculated the DOS for clinical assessment. We also designed a pressure sensing module attached to the ultrasound probe to prevent the probe from coming loose, vibrating, and exerting abnormal pressure on the skin. In the phantom test, the results showed that the error of the DOS that was calculated by RUS was less than 3%. The results of clinical trials obtained from ten patients show that the error between the RUS and clinicians’ measurement was about 10% and had a highly linear correlation (R Square > 0.95). In addition, the reproducibility error was about 3% and could effectively save about 46% of the time during clinical examinations. MDPI 2018-01-29 /pmc/articles/PMC6187484/ /pubmed/30393327 http://dx.doi.org/10.3390/mi9020051 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Du, Yi-Chun
Shih, Jheng-Bang
Wu, Ming-Jui
Chiou, Chung-Yi
Development of an AVF Stenosis Assessment Tool for Hemodialysis Patients Using Robotic Ultrasound System
title Development of an AVF Stenosis Assessment Tool for Hemodialysis Patients Using Robotic Ultrasound System
title_full Development of an AVF Stenosis Assessment Tool for Hemodialysis Patients Using Robotic Ultrasound System
title_fullStr Development of an AVF Stenosis Assessment Tool for Hemodialysis Patients Using Robotic Ultrasound System
title_full_unstemmed Development of an AVF Stenosis Assessment Tool for Hemodialysis Patients Using Robotic Ultrasound System
title_short Development of an AVF Stenosis Assessment Tool for Hemodialysis Patients Using Robotic Ultrasound System
title_sort development of an avf stenosis assessment tool for hemodialysis patients using robotic ultrasound system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187484/
https://www.ncbi.nlm.nih.gov/pubmed/30393327
http://dx.doi.org/10.3390/mi9020051
work_keys_str_mv AT duyichun developmentofanavfstenosisassessmenttoolforhemodialysispatientsusingroboticultrasoundsystem
AT shihjhengbang developmentofanavfstenosisassessmenttoolforhemodialysispatientsusingroboticultrasoundsystem
AT wumingjui developmentofanavfstenosisassessmenttoolforhemodialysispatientsusingroboticultrasoundsystem
AT chiouchungyi developmentofanavfstenosisassessmenttoolforhemodialysispatientsusingroboticultrasoundsystem