Cargando…

Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode

To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl electrode. We then designed a flow-through amperomet...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, He, Chuai, Rongyan, Li, Xin, Zhang, Bing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187539/
https://www.ncbi.nlm.nih.gov/pubmed/30424048
http://dx.doi.org/10.3390/mi9030114
_version_ 1783363043374137344
author Zhang, He
Chuai, Rongyan
Li, Xin
Zhang, Bing
author_facet Zhang, He
Chuai, Rongyan
Li, Xin
Zhang, Bing
author_sort Zhang, He
collection PubMed
description To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl electrode. We then designed a flow-through amperometric sensor and a multilayer microfluidic chip based on the integrated reference electrode. In order to improve the detection signal strength of the flow-through sensor, a numerical simulation model was established. The simulation results showed that a combination of (1) using a step-type detection cell structure that maintains micro-channel width while reducing micro-channel height, and (2) controlling the sample flow rate to limit the mass transfer of the sensor surface effectively, improves the detection signal strength. The step-type detection cell structure had dimensions of 200 μm × 200 μm × 100 μm (length × width × height), and the electroosmotic flow driving voltage was 120 V/cm. Finally, successful trace detection of Mg(2+) and Pb(2+) in the water was achieved using the amperometric sensor and microfluidic chip: detection limits were 5 μmol/L and 84 μmol/L. The preparation of an on-chip flow-through amperometric sensor with an integrated Ag/AgCl reference electrode will facilitate improved portability of microfluidic detection technology.
format Online
Article
Text
id pubmed-6187539
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61875392018-11-01 Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode Zhang, He Chuai, Rongyan Li, Xin Zhang, Bing Micromachines (Basel) Article To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl electrode. We then designed a flow-through amperometric sensor and a multilayer microfluidic chip based on the integrated reference electrode. In order to improve the detection signal strength of the flow-through sensor, a numerical simulation model was established. The simulation results showed that a combination of (1) using a step-type detection cell structure that maintains micro-channel width while reducing micro-channel height, and (2) controlling the sample flow rate to limit the mass transfer of the sensor surface effectively, improves the detection signal strength. The step-type detection cell structure had dimensions of 200 μm × 200 μm × 100 μm (length × width × height), and the electroosmotic flow driving voltage was 120 V/cm. Finally, successful trace detection of Mg(2+) and Pb(2+) in the water was achieved using the amperometric sensor and microfluidic chip: detection limits were 5 μmol/L and 84 μmol/L. The preparation of an on-chip flow-through amperometric sensor with an integrated Ag/AgCl reference electrode will facilitate improved portability of microfluidic detection technology. MDPI 2018-03-07 /pmc/articles/PMC6187539/ /pubmed/30424048 http://dx.doi.org/10.3390/mi9030114 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, He
Chuai, Rongyan
Li, Xin
Zhang, Bing
Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode
title Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode
title_full Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode
title_fullStr Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode
title_full_unstemmed Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode
title_short Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode
title_sort design, preparation and performance study of on-chip flow-through amperometric sensors with an integrated ag/agcl reference electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187539/
https://www.ncbi.nlm.nih.gov/pubmed/30424048
http://dx.doi.org/10.3390/mi9030114
work_keys_str_mv AT zhanghe designpreparationandperformancestudyofonchipflowthroughamperometricsensorswithanintegratedagagclreferenceelectrode
AT chuairongyan designpreparationandperformancestudyofonchipflowthroughamperometricsensorswithanintegratedagagclreferenceelectrode
AT lixin designpreparationandperformancestudyofonchipflowthroughamperometricsensorswithanintegratedagagclreferenceelectrode
AT zhangbing designpreparationandperformancestudyofonchipflowthroughamperometricsensorswithanintegratedagagclreferenceelectrode