Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode
To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl electrode. We then designed a flow-through amperomet...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187539/ https://www.ncbi.nlm.nih.gov/pubmed/30424048 http://dx.doi.org/10.3390/mi9030114 |
_version_ | 1783363043374137344 |
---|---|
author | Zhang, He Chuai, Rongyan Li, Xin Zhang, Bing |
author_facet | Zhang, He Chuai, Rongyan Li, Xin Zhang, Bing |
author_sort | Zhang, He |
collection | PubMed |
description | To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl electrode. We then designed a flow-through amperometric sensor and a multilayer microfluidic chip based on the integrated reference electrode. In order to improve the detection signal strength of the flow-through sensor, a numerical simulation model was established. The simulation results showed that a combination of (1) using a step-type detection cell structure that maintains micro-channel width while reducing micro-channel height, and (2) controlling the sample flow rate to limit the mass transfer of the sensor surface effectively, improves the detection signal strength. The step-type detection cell structure had dimensions of 200 μm × 200 μm × 100 μm (length × width × height), and the electroosmotic flow driving voltage was 120 V/cm. Finally, successful trace detection of Mg(2+) and Pb(2+) in the water was achieved using the amperometric sensor and microfluidic chip: detection limits were 5 μmol/L and 84 μmol/L. The preparation of an on-chip flow-through amperometric sensor with an integrated Ag/AgCl reference electrode will facilitate improved portability of microfluidic detection technology. |
format | Online Article Text |
id | pubmed-6187539 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61875392018-11-01 Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode Zhang, He Chuai, Rongyan Li, Xin Zhang, Bing Micromachines (Basel) Article To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl electrode. We then designed a flow-through amperometric sensor and a multilayer microfluidic chip based on the integrated reference electrode. In order to improve the detection signal strength of the flow-through sensor, a numerical simulation model was established. The simulation results showed that a combination of (1) using a step-type detection cell structure that maintains micro-channel width while reducing micro-channel height, and (2) controlling the sample flow rate to limit the mass transfer of the sensor surface effectively, improves the detection signal strength. The step-type detection cell structure had dimensions of 200 μm × 200 μm × 100 μm (length × width × height), and the electroosmotic flow driving voltage was 120 V/cm. Finally, successful trace detection of Mg(2+) and Pb(2+) in the water was achieved using the amperometric sensor and microfluidic chip: detection limits were 5 μmol/L and 84 μmol/L. The preparation of an on-chip flow-through amperometric sensor with an integrated Ag/AgCl reference electrode will facilitate improved portability of microfluidic detection technology. MDPI 2018-03-07 /pmc/articles/PMC6187539/ /pubmed/30424048 http://dx.doi.org/10.3390/mi9030114 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhang, He Chuai, Rongyan Li, Xin Zhang, Bing Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode |
title | Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode |
title_full | Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode |
title_fullStr | Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode |
title_full_unstemmed | Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode |
title_short | Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode |
title_sort | design, preparation and performance study of on-chip flow-through amperometric sensors with an integrated ag/agcl reference electrode |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187539/ https://www.ncbi.nlm.nih.gov/pubmed/30424048 http://dx.doi.org/10.3390/mi9030114 |
work_keys_str_mv | AT zhanghe designpreparationandperformancestudyofonchipflowthroughamperometricsensorswithanintegratedagagclreferenceelectrode AT chuairongyan designpreparationandperformancestudyofonchipflowthroughamperometricsensorswithanintegratedagagclreferenceelectrode AT lixin designpreparationandperformancestudyofonchipflowthroughamperometricsensorswithanintegratedagagclreferenceelectrode AT zhangbing designpreparationandperformancestudyofonchipflowthroughamperometricsensorswithanintegratedagagclreferenceelectrode |