Cargando…
New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical Tweezer
We propose a new approach to calculate the sensitivity factor of the detector in optical tweezers. In this work, we used a charge-coupled device (CCD) camera and a quadrant photodiode (QPD) for the extraction of the various positions occupied by the trapped object (in this case, silica beads of diff...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187551/ https://www.ncbi.nlm.nih.gov/pubmed/30424358 http://dx.doi.org/10.3390/mi9090425 |
_version_ | 1783363046232555520 |
---|---|
author | Yale, Pavel Konin, Jean-Michel Edoukoua Kouacou, Michel Abaka Zoueu, Jérémie Thouakesseh |
author_facet | Yale, Pavel Konin, Jean-Michel Edoukoua Kouacou, Michel Abaka Zoueu, Jérémie Thouakesseh |
author_sort | Yale, Pavel |
collection | PubMed |
description | We propose a new approach to calculate the sensitivity factor of the detector in optical tweezers. In this work, we used a charge-coupled device (CCD) camera and a quadrant photodiode (QPD) for the extraction of the various positions occupied by the trapped object (in this case, silica beads of different diameters). Image-J software and the Boltzmann statistical method were then used to estimate the sensitivity of the detector. Silica beads of diameter 0.8 µm, 2 µm, a system of 2 µm bead stuck to 4.5 µm one and another system of 2 µm beads stuck to 2 µm one, were studied. This work contributes significantly to making better calibration of the detector without taking into account the geometry of the object imprisoned in the optical trap. We further developed an approach to calculate the interaction force between two microbeads. This approach does not require any knowledge of solvent viscosity and works for all types of samples. |
format | Online Article Text |
id | pubmed-6187551 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61875512018-11-01 New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical Tweezer Yale, Pavel Konin, Jean-Michel Edoukoua Kouacou, Michel Abaka Zoueu, Jérémie Thouakesseh Micromachines (Basel) Article We propose a new approach to calculate the sensitivity factor of the detector in optical tweezers. In this work, we used a charge-coupled device (CCD) camera and a quadrant photodiode (QPD) for the extraction of the various positions occupied by the trapped object (in this case, silica beads of different diameters). Image-J software and the Boltzmann statistical method were then used to estimate the sensitivity of the detector. Silica beads of diameter 0.8 µm, 2 µm, a system of 2 µm bead stuck to 4.5 µm one and another system of 2 µm beads stuck to 2 µm one, were studied. This work contributes significantly to making better calibration of the detector without taking into account the geometry of the object imprisoned in the optical trap. We further developed an approach to calculate the interaction force between two microbeads. This approach does not require any knowledge of solvent viscosity and works for all types of samples. MDPI 2018-08-24 /pmc/articles/PMC6187551/ /pubmed/30424358 http://dx.doi.org/10.3390/mi9090425 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yale, Pavel Konin, Jean-Michel Edoukoua Kouacou, Michel Abaka Zoueu, Jérémie Thouakesseh New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical Tweezer |
title | New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical Tweezer |
title_full | New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical Tweezer |
title_fullStr | New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical Tweezer |
title_full_unstemmed | New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical Tweezer |
title_short | New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical Tweezer |
title_sort | new detector sensitivity calibration and the calculation of the interaction force between particles using an optical tweezer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187551/ https://www.ncbi.nlm.nih.gov/pubmed/30424358 http://dx.doi.org/10.3390/mi9090425 |
work_keys_str_mv | AT yalepavel newdetectorsensitivitycalibrationandthecalculationoftheinteractionforcebetweenparticlesusinganopticaltweezer AT koninjeanmicheledoukoua newdetectorsensitivitycalibrationandthecalculationoftheinteractionforcebetweenparticlesusinganopticaltweezer AT kouacoumichelabaka newdetectorsensitivitycalibrationandthecalculationoftheinteractionforcebetweenparticlesusinganopticaltweezer AT zoueujeremiethouakesseh newdetectorsensitivitycalibrationandthecalculationoftheinteractionforcebetweenparticlesusinganopticaltweezer |