Cargando…
Analysis of Membrane Behavior of a Normally Closed Microvalve Using a Fluid-Structure Interaction Model
In this paper, membrane deflection against fluid flow and opening membrane (threshold) pressure were studied using fluid-structure interaction (FSI) analysis, and compared with experimental data obtained by Jaemin et al. In the current analysis, two different models (I-shaped and V-shaped) were used...
Autores principales: | Natarajan, Guru Prasath, Kim, Sung-Jin, Kim, Chang-Wan |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187868/ https://www.ncbi.nlm.nih.gov/pubmed/30400545 http://dx.doi.org/10.3390/mi8120355 |
Ejemplares similares
-
Actuation Mechanism of Microvalves: A Review
por: Qian, Jin-Yuan, et al.
Publicado: (2020) -
Microvalves for Applications in Centrifugal Microfluidics
por: Peshin, Snehan, et al.
Publicado: (2022) -
Microvalve Bioprinting of MSC-Chondrocyte Co-Cultures
por: Dudman, Joseph, et al.
Publicado: (2021) -
A simple and reliable microfabrication process for a programmable microvalve array
por: Estlack, Zachary, et al.
Publicado: (2022) -
Proportional Microvalve Using a Unimorph Piezoelectric Microactuator
por: Gunda, Arun, et al.
Publicado: (2020)