Cargando…

Low-Cost High-Speed In-Plane Stroboscopic Micro-Motion Analyzer

Instrumentation for high-speed imaging and laser vibrometry is essential for the understanding and analysis of microstructure dynamics, but commercial instruments are largely unaffordable for most microelectromechanical systems (MEMS) laboratories. We present the implementation of a very low cost in...

Descripción completa

Detalles Bibliográficos
Autores principales: Pandey, Shashank S., Banerjee, Aishwaryadev, Karkhanis, Mohit U., Mastrangelo, Carlos H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187908/
https://www.ncbi.nlm.nih.gov/pubmed/30400539
http://dx.doi.org/10.3390/mi8120351
_version_ 1783363113484025856
author Pandey, Shashank S.
Banerjee, Aishwaryadev
Karkhanis, Mohit U.
Mastrangelo, Carlos H.
author_facet Pandey, Shashank S.
Banerjee, Aishwaryadev
Karkhanis, Mohit U.
Mastrangelo, Carlos H.
author_sort Pandey, Shashank S.
collection PubMed
description Instrumentation for high-speed imaging and laser vibrometry is essential for the understanding and analysis of microstructure dynamics, but commercial instruments are largely unaffordable for most microelectromechanical systems (MEMS) laboratories. We present the implementation of a very low cost in-plane micro motion stroboscopic analyzer that can be directly attached to a conventional probe station. The low-cost analyzer has been used to characterize the harmonic motion of 52.1 kHz resonating comb drive microactuators using ~50 ns pulsed light-emitting diode (LED) stroboscope exposure times, producing sharp and high resolution (~0.5 μm) device images at resonance, which rivals those of several orders of magnitude more expensive systems. This paper details the development of the high-speed stroboscopic imaging system and presents experimental results of motion analysis of example microstructures and a discussion of its operating limits. The system is shown to produce stable stroboscopic LED illumination to freeze device images up to 11 MHz.
format Online
Article
Text
id pubmed-6187908
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61879082018-11-01 Low-Cost High-Speed In-Plane Stroboscopic Micro-Motion Analyzer Pandey, Shashank S. Banerjee, Aishwaryadev Karkhanis, Mohit U. Mastrangelo, Carlos H. Micromachines (Basel) Article Instrumentation for high-speed imaging and laser vibrometry is essential for the understanding and analysis of microstructure dynamics, but commercial instruments are largely unaffordable for most microelectromechanical systems (MEMS) laboratories. We present the implementation of a very low cost in-plane micro motion stroboscopic analyzer that can be directly attached to a conventional probe station. The low-cost analyzer has been used to characterize the harmonic motion of 52.1 kHz resonating comb drive microactuators using ~50 ns pulsed light-emitting diode (LED) stroboscope exposure times, producing sharp and high resolution (~0.5 μm) device images at resonance, which rivals those of several orders of magnitude more expensive systems. This paper details the development of the high-speed stroboscopic imaging system and presents experimental results of motion analysis of example microstructures and a discussion of its operating limits. The system is shown to produce stable stroboscopic LED illumination to freeze device images up to 11 MHz. MDPI 2017-11-30 /pmc/articles/PMC6187908/ /pubmed/30400539 http://dx.doi.org/10.3390/mi8120351 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pandey, Shashank S.
Banerjee, Aishwaryadev
Karkhanis, Mohit U.
Mastrangelo, Carlos H.
Low-Cost High-Speed In-Plane Stroboscopic Micro-Motion Analyzer
title Low-Cost High-Speed In-Plane Stroboscopic Micro-Motion Analyzer
title_full Low-Cost High-Speed In-Plane Stroboscopic Micro-Motion Analyzer
title_fullStr Low-Cost High-Speed In-Plane Stroboscopic Micro-Motion Analyzer
title_full_unstemmed Low-Cost High-Speed In-Plane Stroboscopic Micro-Motion Analyzer
title_short Low-Cost High-Speed In-Plane Stroboscopic Micro-Motion Analyzer
title_sort low-cost high-speed in-plane stroboscopic micro-motion analyzer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187908/
https://www.ncbi.nlm.nih.gov/pubmed/30400539
http://dx.doi.org/10.3390/mi8120351
work_keys_str_mv AT pandeyshashanks lowcosthighspeedinplanestroboscopicmicromotionanalyzer
AT banerjeeaishwaryadev lowcosthighspeedinplanestroboscopicmicromotionanalyzer
AT karkhanismohitu lowcosthighspeedinplanestroboscopicmicromotionanalyzer
AT mastrangelocarlosh lowcosthighspeedinplanestroboscopicmicromotionanalyzer