Cargando…
Multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and Neonatal Facial Coding System interrelated during venepuncture in healthy, term neonates?
BACKGROUND: Improving pain and stress assessments in neonates remains important in preventing the short- and long-term consequences. We aimed to identify the relationships between different pain assessment parameters by simultaneously measuring changes in cortical, autonomic, hormonal, physiological...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6188070/ https://www.ncbi.nlm.nih.gov/pubmed/30349352 http://dx.doi.org/10.2147/JPR.S165810 |
_version_ | 1783363152309649408 |
---|---|
author | Roué, Jean-Michel Rioualen, Stéphane Gendras, Julie Misery, Laurent Gouillou, Maëlenn Sizun, Jacques |
author_facet | Roué, Jean-Michel Rioualen, Stéphane Gendras, Julie Misery, Laurent Gouillou, Maëlenn Sizun, Jacques |
author_sort | Roué, Jean-Michel |
collection | PubMed |
description | BACKGROUND: Improving pain and stress assessments in neonates remains important in preventing the short- and long-term consequences. We aimed to identify the relationships between different pain assessment parameters by simultaneously measuring changes in cortical, autonomic, hormonal, physiological, and behavioral evoked responses to venepuncture in healthy, full-term neonates. METHODS: This observational, prospective study (ancillary to the ACTISUCROSE trial) included 113 healthy, 3-day old, full-term neonates who underwent venepuncture for systematic neonatal screening, from July to October 2013, in a tertiary-level maternity ward of a university hospital. During venepuncture, we simultaneously measured the cortical single-channel near-infrared spectroscopy (NIRS) signals, foot skin conductance, salivary cortisol, physiological responses, and behavioral (Neonatal Facial Coding System [NFCS]) evoked responses. RESULTS: Regarding the NIRS analysis, the highest correlation was between the NFCS at venepuncture and the change in NIRS integrated values of total hemoglobin (r=0.41, P<0.001) or oxygenated hemoglobin (r=0.27, P<0.001). The NFCS at venepuncture was moderately positively correlated with changes in salivary cortisol (r=0.42, P<0.001) and skin conductance (r=0.29, P<0.001). Salivary cortisol and skin conductance changes were not correlated; the latter parameters were not correlated with heart rate, respiratory rate, or SpO2. CONCLUSION: During venepuncture, NFCS was mildly or moderately correlated with salivary cortisol, skin conductance, and cortical NIRS changes. |
format | Online Article Text |
id | pubmed-6188070 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-61880702018-10-22 Multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and Neonatal Facial Coding System interrelated during venepuncture in healthy, term neonates? Roué, Jean-Michel Rioualen, Stéphane Gendras, Julie Misery, Laurent Gouillou, Maëlenn Sizun, Jacques J Pain Res Original Research BACKGROUND: Improving pain and stress assessments in neonates remains important in preventing the short- and long-term consequences. We aimed to identify the relationships between different pain assessment parameters by simultaneously measuring changes in cortical, autonomic, hormonal, physiological, and behavioral evoked responses to venepuncture in healthy, full-term neonates. METHODS: This observational, prospective study (ancillary to the ACTISUCROSE trial) included 113 healthy, 3-day old, full-term neonates who underwent venepuncture for systematic neonatal screening, from July to October 2013, in a tertiary-level maternity ward of a university hospital. During venepuncture, we simultaneously measured the cortical single-channel near-infrared spectroscopy (NIRS) signals, foot skin conductance, salivary cortisol, physiological responses, and behavioral (Neonatal Facial Coding System [NFCS]) evoked responses. RESULTS: Regarding the NIRS analysis, the highest correlation was between the NFCS at venepuncture and the change in NIRS integrated values of total hemoglobin (r=0.41, P<0.001) or oxygenated hemoglobin (r=0.27, P<0.001). The NFCS at venepuncture was moderately positively correlated with changes in salivary cortisol (r=0.42, P<0.001) and skin conductance (r=0.29, P<0.001). Salivary cortisol and skin conductance changes were not correlated; the latter parameters were not correlated with heart rate, respiratory rate, or SpO2. CONCLUSION: During venepuncture, NFCS was mildly or moderately correlated with salivary cortisol, skin conductance, and cortical NIRS changes. Dove Medical Press 2018-10-11 /pmc/articles/PMC6188070/ /pubmed/30349352 http://dx.doi.org/10.2147/JPR.S165810 Text en © 2018 Roué et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php (http://https://www.dovepress.com/terms.php) and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (http://http://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Roué, Jean-Michel Rioualen, Stéphane Gendras, Julie Misery, Laurent Gouillou, Maëlenn Sizun, Jacques Multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and Neonatal Facial Coding System interrelated during venepuncture in healthy, term neonates? |
title | Multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and Neonatal Facial Coding System interrelated during venepuncture in healthy, term neonates? |
title_full | Multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and Neonatal Facial Coding System interrelated during venepuncture in healthy, term neonates? |
title_fullStr | Multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and Neonatal Facial Coding System interrelated during venepuncture in healthy, term neonates? |
title_full_unstemmed | Multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and Neonatal Facial Coding System interrelated during venepuncture in healthy, term neonates? |
title_short | Multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and Neonatal Facial Coding System interrelated during venepuncture in healthy, term neonates? |
title_sort | multi-modal pain assessment: are near-infrared spectroscopy, skin conductance, salivary cortisol, physiologic parameters, and neonatal facial coding system interrelated during venepuncture in healthy, term neonates? |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6188070/ https://www.ncbi.nlm.nih.gov/pubmed/30349352 http://dx.doi.org/10.2147/JPR.S165810 |
work_keys_str_mv | AT rouejeanmichel multimodalpainassessmentarenearinfraredspectroscopyskinconductancesalivarycortisolphysiologicparametersandneonatalfacialcodingsysteminterrelatedduringvenepunctureinhealthytermneonates AT rioualenstephane multimodalpainassessmentarenearinfraredspectroscopyskinconductancesalivarycortisolphysiologicparametersandneonatalfacialcodingsysteminterrelatedduringvenepunctureinhealthytermneonates AT gendrasjulie multimodalpainassessmentarenearinfraredspectroscopyskinconductancesalivarycortisolphysiologicparametersandneonatalfacialcodingsysteminterrelatedduringvenepunctureinhealthytermneonates AT miserylaurent multimodalpainassessmentarenearinfraredspectroscopyskinconductancesalivarycortisolphysiologicparametersandneonatalfacialcodingsysteminterrelatedduringvenepunctureinhealthytermneonates AT gouilloumaelenn multimodalpainassessmentarenearinfraredspectroscopyskinconductancesalivarycortisolphysiologicparametersandneonatalfacialcodingsysteminterrelatedduringvenepunctureinhealthytermneonates AT sizunjacques multimodalpainassessmentarenearinfraredspectroscopyskinconductancesalivarycortisolphysiologicparametersandneonatalfacialcodingsysteminterrelatedduringvenepunctureinhealthytermneonates |