Introduction Damage to the posterior interosseous nerve (PIN) is a known complication when using a cortical button during distal biceps tendon repair. Prior studies show that the trajectory of the drill through the biceps tuberosity can affect the distance from the PIN. We develop a mathematical mod...

Descripción completa

Detalles Bibliográficos
Autores principales: Klebanov, Nikolai, Wei, David H, Harrison, Brendan J, Kimball, Hervey L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6188161/
https://www.ncbi.nlm.nih.gov/pubmed/30345198
http://dx.doi.org/10.7759/cureus.3141
_version_ 1783363170969059328
author Klebanov, Nikolai
Wei, David H
Harrison, Brendan J
Kimball, Hervey L
author_facet Klebanov, Nikolai
Wei, David H
Harrison, Brendan J
Kimball, Hervey L
author_sort Klebanov, Nikolai
collection PubMed
description Introduction Damage to the posterior interosseous nerve (PIN) is a known complication when using a cortical button during distal biceps tendon repair. Prior studies show that the trajectory of the drill through the biceps tuberosity can affect the distance from the PIN. We develop a mathematical model to predict the location of the tuberosity based on a palpable bony landmark and patient demographic factors. Methods The medical charts and elbow radiographs of (n = 82) adult patients were retrospectively reviewed. Using standard radiographic software, two observers measured the distance from the olecranon tip to the center of the biceps tuberosity. Multivariate regression analysis was used to build a linear model. The model was cross-validated with five arms from three distinct cadavers. A surgical wire was guided into the volar aspect of each forearm using the model, and a dissection was then performed to assess the proximity of the surgical wire to the insertion of the biceps tendon on the radial tuberosity. Results Olecranon-tuberosity distance (OTD) ranged from 52.3 mm to 77.2 mm (mean 66.5 mm). Univariate analyses revealed males had significantly longer OTD (mean 69.3 mm) compared to females (mean 61.2 mm, t-test, p < 0.001). Increased body mass index (BMI) weakly correlated with increased distance (Pearson’s r = 0.22, p = 0.048). Height showed strong positive correlation with increased distance (r = 0.77, p < 0.001). Multivariate regression revealed that significant predictive factors for olecranon-tuberosity distance were height (coefficient = 35.8, p < 0.001), BMI (coefficient = 0.14, p = 0.032), and male sex (coefficient = 3.17, p = 0.0039). The average error in the cadaveric validation, measured as distance from the surgical wire to the distal biceps insertion was 1.8 mm. Conclusion A highly accurate mathematical model can be used to predict the location of the biceps tuberosity in relation to the palpable tip of the olecranon, based only on height, BMI, and sex of the patient. Knowledge of this distance can guide accurate placement of the skin incision when a transverse single-incision approach is utilized for repair of the distal biceps tendon using a cortical button. Diagnostics showed the model to be less accurate near the extremes of the measurement. Since patients with a target incision point far removed from average would most benefit from such a model, we will continue by identifying and enrolling patients at the low and high ends of the range. We further hypothesize that the technique described above could be similarly applied to benefit other procedures.
format Online
Article
Text
id pubmed-6188161
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-61881612018-10-20 Optimization of Anterior Incision Placement for Distal Biceps Repair Klebanov, Nikolai Wei, David H Harrison, Brendan J Kimball, Hervey L Cureus Medical Simulation Introduction Damage to the posterior interosseous nerve (PIN) is a known complication when using a cortical button during distal biceps tendon repair. Prior studies show that the trajectory of the drill through the biceps tuberosity can affect the distance from the PIN. We develop a mathematical model to predict the location of the tuberosity based on a palpable bony landmark and patient demographic factors. Methods The medical charts and elbow radiographs of (n = 82) adult patients were retrospectively reviewed. Using standard radiographic software, two observers measured the distance from the olecranon tip to the center of the biceps tuberosity. Multivariate regression analysis was used to build a linear model. The model was cross-validated with five arms from three distinct cadavers. A surgical wire was guided into the volar aspect of each forearm using the model, and a dissection was then performed to assess the proximity of the surgical wire to the insertion of the biceps tendon on the radial tuberosity. Results Olecranon-tuberosity distance (OTD) ranged from 52.3 mm to 77.2 mm (mean 66.5 mm). Univariate analyses revealed males had significantly longer OTD (mean 69.3 mm) compared to females (mean 61.2 mm, t-test, p < 0.001). Increased body mass index (BMI) weakly correlated with increased distance (Pearson’s r = 0.22, p = 0.048). Height showed strong positive correlation with increased distance (r = 0.77, p < 0.001). Multivariate regression revealed that significant predictive factors for olecranon-tuberosity distance were height (coefficient = 35.8, p < 0.001), BMI (coefficient = 0.14, p = 0.032), and male sex (coefficient = 3.17, p = 0.0039). The average error in the cadaveric validation, measured as distance from the surgical wire to the distal biceps insertion was 1.8 mm. Conclusion A highly accurate mathematical model can be used to predict the location of the biceps tuberosity in relation to the palpable tip of the olecranon, based only on height, BMI, and sex of the patient. Knowledge of this distance can guide accurate placement of the skin incision when a transverse single-incision approach is utilized for repair of the distal biceps tendon using a cortical button. Diagnostics showed the model to be less accurate near the extremes of the measurement. Since patients with a target incision point far removed from average would most benefit from such a model, we will continue by identifying and enrolling patients at the low and high ends of the range. We further hypothesize that the technique described above could be similarly applied to benefit other procedures. Cureus 2018-08-14 /pmc/articles/PMC6188161/ /pubmed/30345198 http://dx.doi.org/10.7759/cureus.3141 Text en Copyright © 2018, Klebanov et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Simulation
Klebanov, Nikolai
Wei, David H
Harrison, Brendan J
Kimball, Hervey L
Optimization of Anterior Incision Placement for Distal Biceps Repair
title Optimization of Anterior Incision Placement for Distal Biceps Repair
title_full Optimization of Anterior Incision Placement for Distal Biceps Repair
title_fullStr Optimization of Anterior Incision Placement for Distal Biceps Repair
title_full_unstemmed Optimization of Anterior Incision Placement for Distal Biceps Repair
title_short Optimization of Anterior Incision Placement for Distal Biceps Repair
title_sort optimization of anterior incision placement for distal biceps repair
topic Medical Simulation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6188161/
https://www.ncbi.nlm.nih.gov/pubmed/30345198
http://dx.doi.org/10.7759/cureus.3141
work_keys_str_mv AT klebanovnikolai optimizationofanteriorincisionplacementfordistalbicepsrepair
AT weidavidh optimizationofanteriorincisionplacementfordistalbicepsrepair
AT harrisonbrendanj optimizationofanteriorincisionplacementfordistalbicepsrepair
AT kimballherveyl optimizationofanteriorincisionplacementfordistalbicepsrepair