Cargando…
Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans
PURPOSE: To compare the diagnostic capability of three-dimensional (3D) macular parameters against traditional two-dimensional (2D) retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography. To determine if manual correction and interpolation of B-scans improve th...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6188465/ https://www.ncbi.nlm.nih.gov/pubmed/30326067 http://dx.doi.org/10.1167/iovs.18-23813 |
_version_ | 1783363186672533504 |
---|---|
author | Verticchio Vercellin, Alice C. Jassim, Firas Poon, Linda Yi-Chieh Tsikata, Edem Braaf, Boy Shah, Sneha Ben-David, Geulah Shieh, Eric Lee, Ramon Simavli, Huseyin Que, Christian J. Papadogeorgou, Georgia Guo, Rong Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. |
author_facet | Verticchio Vercellin, Alice C. Jassim, Firas Poon, Linda Yi-Chieh Tsikata, Edem Braaf, Boy Shah, Sneha Ben-David, Geulah Shieh, Eric Lee, Ramon Simavli, Huseyin Que, Christian J. Papadogeorgou, Georgia Guo, Rong Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. |
author_sort | Verticchio Vercellin, Alice C. |
collection | PubMed |
description | PURPOSE: To compare the diagnostic capability of three-dimensional (3D) macular parameters against traditional two-dimensional (2D) retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography. To determine if manual correction and interpolation of B-scans improve the ability of 3D macular parameters to diagnose glaucoma. METHODS: A total of 101 open angle glaucoma patients (29 with early glaucoma) and 57 healthy subjects had peripapillary 2D RNFL thickness and 3D macular volume scans. Four parameters were calculated for six different-sized annuli: total macular thickness (M-thickness), total macular volume (M-volume), ganglion cell complex (GCC) thickness, and GCC volume of the innermost 3 macular layers (retinal nerve fiber layer + ganglion cell layer + inner plexiform layer). All macular parameters were calculated with and without correction and interpolation of frames with artifacts. The areas under the receiver operating characteristic curves (AUROC) were calculated for all the parameters. RESULTS: The 3D macular parameter with the best diagnostic performance was GCC-volume-34, with an inner diameter of 3 mm and an outer of 4 mm. The AUROC for RNFL thickness and GCC-volume-34 were statistically similar for all regions (global: RNFL thickness 0.956, GCC-volume-34 0.939, P value = 0.3827), except for the temporal GCC-volume-34, which was significantly better than temporal RNFL thickness (P value = 0.0067). Correction of artifacts did not significantly change the AUROC of macular parameters (P values between 0.8452 and 1.0000). CONCLUSIONS: The diagnostic performance of best macular parameters (GCC-volume-34 and GCC-thickness-34) were similar to or better than 2D RNFL thickness. Manual correction of artifacts with data interpolation is unnecessary in the clinical setting. |
format | Online Article Text |
id | pubmed-6188465 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-61884652018-10-19 Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans Verticchio Vercellin, Alice C. Jassim, Firas Poon, Linda Yi-Chieh Tsikata, Edem Braaf, Boy Shah, Sneha Ben-David, Geulah Shieh, Eric Lee, Ramon Simavli, Huseyin Que, Christian J. Papadogeorgou, Georgia Guo, Rong Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. Invest Ophthalmol Vis Sci Glaucoma PURPOSE: To compare the diagnostic capability of three-dimensional (3D) macular parameters against traditional two-dimensional (2D) retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography. To determine if manual correction and interpolation of B-scans improve the ability of 3D macular parameters to diagnose glaucoma. METHODS: A total of 101 open angle glaucoma patients (29 with early glaucoma) and 57 healthy subjects had peripapillary 2D RNFL thickness and 3D macular volume scans. Four parameters were calculated for six different-sized annuli: total macular thickness (M-thickness), total macular volume (M-volume), ganglion cell complex (GCC) thickness, and GCC volume of the innermost 3 macular layers (retinal nerve fiber layer + ganglion cell layer + inner plexiform layer). All macular parameters were calculated with and without correction and interpolation of frames with artifacts. The areas under the receiver operating characteristic curves (AUROC) were calculated for all the parameters. RESULTS: The 3D macular parameter with the best diagnostic performance was GCC-volume-34, with an inner diameter of 3 mm and an outer of 4 mm. The AUROC for RNFL thickness and GCC-volume-34 were statistically similar for all regions (global: RNFL thickness 0.956, GCC-volume-34 0.939, P value = 0.3827), except for the temporal GCC-volume-34, which was significantly better than temporal RNFL thickness (P value = 0.0067). Correction of artifacts did not significantly change the AUROC of macular parameters (P values between 0.8452 and 1.0000). CONCLUSIONS: The diagnostic performance of best macular parameters (GCC-volume-34 and GCC-thickness-34) were similar to or better than 2D RNFL thickness. Manual correction of artifacts with data interpolation is unnecessary in the clinical setting. The Association for Research in Vision and Ophthalmology 2018-10 /pmc/articles/PMC6188465/ /pubmed/30326067 http://dx.doi.org/10.1167/iovs.18-23813 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Glaucoma Verticchio Vercellin, Alice C. Jassim, Firas Poon, Linda Yi-Chieh Tsikata, Edem Braaf, Boy Shah, Sneha Ben-David, Geulah Shieh, Eric Lee, Ramon Simavli, Huseyin Que, Christian J. Papadogeorgou, Georgia Guo, Rong Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans |
title | Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans |
title_full | Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans |
title_fullStr | Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans |
title_full_unstemmed | Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans |
title_short | Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans |
title_sort | diagnostic capability of three-dimensional macular parameters for glaucoma using optical coherence tomography volume scans |
topic | Glaucoma |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6188465/ https://www.ncbi.nlm.nih.gov/pubmed/30326067 http://dx.doi.org/10.1167/iovs.18-23813 |
work_keys_str_mv | AT verticchiovercellinalicec diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT jassimfiras diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT poonlindayichieh diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT tsikataedem diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT braafboy diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT shahsneha diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT bendavidgeulah diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT shieheric diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT leeramon diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT simavlihuseyin diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT quechristianj diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT papadogeorgougeorgia diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT guorong diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT vakocbenjaminj diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT boumabrette diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT deboerjohannesf diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans AT chenteresac diagnosticcapabilityofthreedimensionalmacularparametersforglaucomausingopticalcoherencetomographyvolumescans |