A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories
Multi-center studies in specific airway resistance have shown significant inter laboratory variability. Comparison of plethysmographic equipment using a lung model easily transportable from one site to another should be of help to international normative studies. A resistor made of parallel capillar...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189406/ https://www.ncbi.nlm.nih.gov/pubmed/30356753 http://dx.doi.org/10.3389/fphys.2018.01408 |
_version_ | 1783363364849713152 |
---|---|
author | Demoulin, Bruno Ioan, Iulia Duvivier, Claude Bonabel, Claude Schweitzer, Cyril Marchal, François Demoulin-Alexikova, Silvia |
author_facet | Demoulin, Bruno Ioan, Iulia Duvivier, Claude Bonabel, Claude Schweitzer, Cyril Marchal, François Demoulin-Alexikova, Silvia |
author_sort | Demoulin, Bruno |
collection | PubMed |
description | Multi-center studies in specific airway resistance have shown significant inter laboratory variability. Comparison of plethysmographic equipment using a lung model easily transportable from one site to another should be of help to international normative studies. A resistor made of parallel capillary tubes – insuring adequate linearity within 1 L/sec – was connected to a glass bottle. Thermal time constants were measured while the bottle was empty and while stuffed with steel wool. In the latter, isothermal condition was estimated to occur only at very low frequency (around 0.01 Hz) and gas compression was polytropic up to 0.6 Hz. With the empty analog, adiabatic gas compression was estimated to occur at frequencies ≥0.2 Hz, and more accurate volume estimation was obtained. The empty analog volume and specific resistance measured in a body plethysmograph on different days indicated within 5% accuracy as well as intersession repeatability. It is concluded that a physical analog built out of simple material provides accurate measurements of specific resistance. The apparatus should be of help to compare plethysmographic equipments from different laboratories. |
format | Online Article Text |
id | pubmed-6189406 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-61894062018-10-23 A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories Demoulin, Bruno Ioan, Iulia Duvivier, Claude Bonabel, Claude Schweitzer, Cyril Marchal, François Demoulin-Alexikova, Silvia Front Physiol Physiology Multi-center studies in specific airway resistance have shown significant inter laboratory variability. Comparison of plethysmographic equipment using a lung model easily transportable from one site to another should be of help to international normative studies. A resistor made of parallel capillary tubes – insuring adequate linearity within 1 L/sec – was connected to a glass bottle. Thermal time constants were measured while the bottle was empty and while stuffed with steel wool. In the latter, isothermal condition was estimated to occur only at very low frequency (around 0.01 Hz) and gas compression was polytropic up to 0.6 Hz. With the empty analog, adiabatic gas compression was estimated to occur at frequencies ≥0.2 Hz, and more accurate volume estimation was obtained. The empty analog volume and specific resistance measured in a body plethysmograph on different days indicated within 5% accuracy as well as intersession repeatability. It is concluded that a physical analog built out of simple material provides accurate measurements of specific resistance. The apparatus should be of help to compare plethysmographic equipments from different laboratories. Frontiers Media S.A. 2018-10-09 /pmc/articles/PMC6189406/ /pubmed/30356753 http://dx.doi.org/10.3389/fphys.2018.01408 Text en Copyright © 2018 Demoulin, Ioan, Duvivier, Bonabel, Schweitzer, Marchal and Demoulin-Alexikova. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Demoulin, Bruno Ioan, Iulia Duvivier, Claude Bonabel, Claude Schweitzer, Cyril Marchal, François Demoulin-Alexikova, Silvia A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories |
title | A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories |
title_full | A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories |
title_fullStr | A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories |
title_full_unstemmed | A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories |
title_short | A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories |
title_sort | calibration device to compare body plethysmographs among pediatric lung function laboratories |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189406/ https://www.ncbi.nlm.nih.gov/pubmed/30356753 http://dx.doi.org/10.3389/fphys.2018.01408 |
work_keys_str_mv | AT demoulinbruno acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT ioaniulia acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT duvivierclaude acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT bonabelclaude acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT schweitzercyril acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT marchalfrancois acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT demoulinalexikovasilvia acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT demoulinbruno calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT ioaniulia calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT duvivierclaude calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT bonabelclaude calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT schweitzercyril calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT marchalfrancois calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories AT demoulinalexikovasilvia calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories |