Cargando…

A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories

Multi-center studies in specific airway resistance have shown significant inter laboratory variability. Comparison of plethysmographic equipment using a lung model easily transportable from one site to another should be of help to international normative studies. A resistor made of parallel capillar...

Descripción completa

Detalles Bibliográficos
Autores principales: Demoulin, Bruno, Ioan, Iulia, Duvivier, Claude, Bonabel, Claude, Schweitzer, Cyril, Marchal, François, Demoulin-Alexikova, Silvia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189406/
https://www.ncbi.nlm.nih.gov/pubmed/30356753
http://dx.doi.org/10.3389/fphys.2018.01408
_version_ 1783363364849713152
author Demoulin, Bruno
Ioan, Iulia
Duvivier, Claude
Bonabel, Claude
Schweitzer, Cyril
Marchal, François
Demoulin-Alexikova, Silvia
author_facet Demoulin, Bruno
Ioan, Iulia
Duvivier, Claude
Bonabel, Claude
Schweitzer, Cyril
Marchal, François
Demoulin-Alexikova, Silvia
author_sort Demoulin, Bruno
collection PubMed
description Multi-center studies in specific airway resistance have shown significant inter laboratory variability. Comparison of plethysmographic equipment using a lung model easily transportable from one site to another should be of help to international normative studies. A resistor made of parallel capillary tubes – insuring adequate linearity within 1 L/sec – was connected to a glass bottle. Thermal time constants were measured while the bottle was empty and while stuffed with steel wool. In the latter, isothermal condition was estimated to occur only at very low frequency (around 0.01 Hz) and gas compression was polytropic up to 0.6 Hz. With the empty analog, adiabatic gas compression was estimated to occur at frequencies ≥0.2 Hz, and more accurate volume estimation was obtained. The empty analog volume and specific resistance measured in a body plethysmograph on different days indicated within 5% accuracy as well as intersession repeatability. It is concluded that a physical analog built out of simple material provides accurate measurements of specific resistance. The apparatus should be of help to compare plethysmographic equipments from different laboratories.
format Online
Article
Text
id pubmed-6189406
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-61894062018-10-23 A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories Demoulin, Bruno Ioan, Iulia Duvivier, Claude Bonabel, Claude Schweitzer, Cyril Marchal, François Demoulin-Alexikova, Silvia Front Physiol Physiology Multi-center studies in specific airway resistance have shown significant inter laboratory variability. Comparison of plethysmographic equipment using a lung model easily transportable from one site to another should be of help to international normative studies. A resistor made of parallel capillary tubes – insuring adequate linearity within 1 L/sec – was connected to a glass bottle. Thermal time constants were measured while the bottle was empty and while stuffed with steel wool. In the latter, isothermal condition was estimated to occur only at very low frequency (around 0.01 Hz) and gas compression was polytropic up to 0.6 Hz. With the empty analog, adiabatic gas compression was estimated to occur at frequencies ≥0.2 Hz, and more accurate volume estimation was obtained. The empty analog volume and specific resistance measured in a body plethysmograph on different days indicated within 5% accuracy as well as intersession repeatability. It is concluded that a physical analog built out of simple material provides accurate measurements of specific resistance. The apparatus should be of help to compare plethysmographic equipments from different laboratories. Frontiers Media S.A. 2018-10-09 /pmc/articles/PMC6189406/ /pubmed/30356753 http://dx.doi.org/10.3389/fphys.2018.01408 Text en Copyright © 2018 Demoulin, Ioan, Duvivier, Bonabel, Schweitzer, Marchal and Demoulin-Alexikova. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Demoulin, Bruno
Ioan, Iulia
Duvivier, Claude
Bonabel, Claude
Schweitzer, Cyril
Marchal, François
Demoulin-Alexikova, Silvia
A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories
title A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories
title_full A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories
title_fullStr A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories
title_full_unstemmed A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories
title_short A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories
title_sort calibration device to compare body plethysmographs among pediatric lung function laboratories
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189406/
https://www.ncbi.nlm.nih.gov/pubmed/30356753
http://dx.doi.org/10.3389/fphys.2018.01408
work_keys_str_mv AT demoulinbruno acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT ioaniulia acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT duvivierclaude acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT bonabelclaude acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT schweitzercyril acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT marchalfrancois acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT demoulinalexikovasilvia acalibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT demoulinbruno calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT ioaniulia calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT duvivierclaude calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT bonabelclaude calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT schweitzercyril calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT marchalfrancois calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories
AT demoulinalexikovasilvia calibrationdevicetocomparebodyplethysmographsamongpediatriclungfunctionlaboratories