Cargando…

Preparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4

An ultrasensitive and rapid sandwich-type chemiluminescence immunoassay (CLIA) was developed for the clinical determination of human epididymis protein 4 (HE4) in human serum, using GoldMag nanoparticles as solid phase and acridinium ester (AE) as chemiluminescence system (GMP-CLIA). The process of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Ting, Zhang, Mengdan, Wan, Yinsheng, Cui, Yali, Ma, Le
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189797/
http://dx.doi.org/10.3390/mi8050149
_version_ 1783363433201139712
author Ma, Ting
Zhang, Mengdan
Wan, Yinsheng
Cui, Yali
Ma, Le
author_facet Ma, Ting
Zhang, Mengdan
Wan, Yinsheng
Cui, Yali
Ma, Le
author_sort Ma, Ting
collection PubMed
description An ultrasensitive and rapid sandwich-type chemiluminescence immunoassay (CLIA) was developed for the clinical determination of human epididymis protein 4 (HE4) in human serum, using GoldMag nanoparticles as solid phase and acridinium ester (AE) as chemiluminescence system (GMP-CLIA). The process of AE labeling antibodies was systematically studied and evaluated. The effect of varies factors such as molar ratio of AE to antibodies, labeling time, and the components of elution buffer and trigger solution were optimized. Under the selected conditions, AE labeling experiments were successfully performed with the average labeling efficiency of 1.92 ± 0.08, and antibody utilization rate of 69.77 ± 1.19%. Antibody activity remained unchanged after labeling. The established GMP-CLIA method can detect HE4 in the range of 0.25–50 ng·mL(−1) (10–2000 pM) with a detection limit of 0.084 ng·mL(−1) (3.36 pM). The sensitivity has reached a high level, comparable with the current commercial detection kits. This proposed method has been successfully applied to the clinical determination of HE4 in 65 human sera. The results showed a good correlation with a clinical method, microplate-based chemiluminescence enzyme immunoassay (CLEIA), with the correlation coefficient of 0.9594.
format Online
Article
Text
id pubmed-6189797
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61897972018-11-01 Preparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4 Ma, Ting Zhang, Mengdan Wan, Yinsheng Cui, Yali Ma, Le Micromachines (Basel) Article An ultrasensitive and rapid sandwich-type chemiluminescence immunoassay (CLIA) was developed for the clinical determination of human epididymis protein 4 (HE4) in human serum, using GoldMag nanoparticles as solid phase and acridinium ester (AE) as chemiluminescence system (GMP-CLIA). The process of AE labeling antibodies was systematically studied and evaluated. The effect of varies factors such as molar ratio of AE to antibodies, labeling time, and the components of elution buffer and trigger solution were optimized. Under the selected conditions, AE labeling experiments were successfully performed with the average labeling efficiency of 1.92 ± 0.08, and antibody utilization rate of 69.77 ± 1.19%. Antibody activity remained unchanged after labeling. The established GMP-CLIA method can detect HE4 in the range of 0.25–50 ng·mL(−1) (10–2000 pM) with a detection limit of 0.084 ng·mL(−1) (3.36 pM). The sensitivity has reached a high level, comparable with the current commercial detection kits. This proposed method has been successfully applied to the clinical determination of HE4 in 65 human sera. The results showed a good correlation with a clinical method, microplate-based chemiluminescence enzyme immunoassay (CLEIA), with the correlation coefficient of 0.9594. MDPI 2017-05-07 /pmc/articles/PMC6189797/ http://dx.doi.org/10.3390/mi8050149 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ma, Ting
Zhang, Mengdan
Wan, Yinsheng
Cui, Yali
Ma, Le
Preparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4
title Preparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4
title_full Preparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4
title_fullStr Preparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4
title_full_unstemmed Preparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4
title_short Preparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4
title_sort preparation of an acridinium ester-labeled antibody and its application in goldmag nanoparticle-based, ultrasensitive chemiluminescence immunoassay for the detection of human epididymis protein 4
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189797/
http://dx.doi.org/10.3390/mi8050149
work_keys_str_mv AT mating preparationofanacridiniumesterlabeledantibodyanditsapplicationingoldmagnanoparticlebasedultrasensitivechemiluminescenceimmunoassayforthedetectionofhumanepididymisprotein4
AT zhangmengdan preparationofanacridiniumesterlabeledantibodyanditsapplicationingoldmagnanoparticlebasedultrasensitivechemiluminescenceimmunoassayforthedetectionofhumanepididymisprotein4
AT wanyinsheng preparationofanacridiniumesterlabeledantibodyanditsapplicationingoldmagnanoparticlebasedultrasensitivechemiluminescenceimmunoassayforthedetectionofhumanepididymisprotein4
AT cuiyali preparationofanacridiniumesterlabeledantibodyanditsapplicationingoldmagnanoparticlebasedultrasensitivechemiluminescenceimmunoassayforthedetectionofhumanepididymisprotein4
AT male preparationofanacridiniumesterlabeledantibodyanditsapplicationingoldmagnanoparticlebasedultrasensitivechemiluminescenceimmunoassayforthedetectionofhumanepididymisprotein4