Cargando…
Electromagnetic Linear Vibration Energy Harvester Using Sliding Permanent Magnet Array and Ferrofluid as a Lubricant
We present an electromagnetic linear vibration energy harvester with an array of rectangular permanent magnets as a springless proof mass. Instead of supporting the magnet assembly with spring element, ferrofluid has been used as a lubricating material. When external vibration is applied laterally t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189813/ https://www.ncbi.nlm.nih.gov/pubmed/30400478 http://dx.doi.org/10.3390/mi8100288 |
_version_ | 1783363436912050176 |
---|---|
author | Chae, Song Hee Ju, Suna Choi, Yunhee Chi, Ye-Eun Ji, Chang-Hyeon |
author_facet | Chae, Song Hee Ju, Suna Choi, Yunhee Chi, Ye-Eun Ji, Chang-Hyeon |
author_sort | Chae, Song Hee |
collection | PubMed |
description | We present an electromagnetic linear vibration energy harvester with an array of rectangular permanent magnets as a springless proof mass. Instead of supporting the magnet assembly with spring element, ferrofluid has been used as a lubricating material. When external vibration is applied laterally to the harvester, magnet assembly slides back and forth on the channel with reduced friction and wear due to ferrofluid, which significantly improves the long-term reliability of the device. Electric power is generated across an array of copper windings formed at the bottom of the aluminum housing. A proof-of-concept harvester has been fabricated and tested with a vibration exciter at various input frequencies and accelerations. For the device where 5 μL of ferrofluid was used for lubrication, maximum output power of 493 μW has been generated, which was 4.37% higher than that without ferrofluid. Long-term reliability improvement due to ferrofluid lubrication has also been verified. For the device with ferrofluid, 1.02% decrease of output power has been observed, in contrast to 59.73% decrease of output power without ferrofluid after 93,600 cycles. |
format | Online Article Text |
id | pubmed-6189813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61898132018-11-01 Electromagnetic Linear Vibration Energy Harvester Using Sliding Permanent Magnet Array and Ferrofluid as a Lubricant Chae, Song Hee Ju, Suna Choi, Yunhee Chi, Ye-Eun Ji, Chang-Hyeon Micromachines (Basel) Article We present an electromagnetic linear vibration energy harvester with an array of rectangular permanent magnets as a springless proof mass. Instead of supporting the magnet assembly with spring element, ferrofluid has been used as a lubricating material. When external vibration is applied laterally to the harvester, magnet assembly slides back and forth on the channel with reduced friction and wear due to ferrofluid, which significantly improves the long-term reliability of the device. Electric power is generated across an array of copper windings formed at the bottom of the aluminum housing. A proof-of-concept harvester has been fabricated and tested with a vibration exciter at various input frequencies and accelerations. For the device where 5 μL of ferrofluid was used for lubrication, maximum output power of 493 μW has been generated, which was 4.37% higher than that without ferrofluid. Long-term reliability improvement due to ferrofluid lubrication has also been verified. For the device with ferrofluid, 1.02% decrease of output power has been observed, in contrast to 59.73% decrease of output power without ferrofluid after 93,600 cycles. MDPI 2017-09-22 /pmc/articles/PMC6189813/ /pubmed/30400478 http://dx.doi.org/10.3390/mi8100288 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chae, Song Hee Ju, Suna Choi, Yunhee Chi, Ye-Eun Ji, Chang-Hyeon Electromagnetic Linear Vibration Energy Harvester Using Sliding Permanent Magnet Array and Ferrofluid as a Lubricant |
title | Electromagnetic Linear Vibration Energy Harvester Using Sliding Permanent Magnet Array and Ferrofluid as a Lubricant |
title_full | Electromagnetic Linear Vibration Energy Harvester Using Sliding Permanent Magnet Array and Ferrofluid as a Lubricant |
title_fullStr | Electromagnetic Linear Vibration Energy Harvester Using Sliding Permanent Magnet Array and Ferrofluid as a Lubricant |
title_full_unstemmed | Electromagnetic Linear Vibration Energy Harvester Using Sliding Permanent Magnet Array and Ferrofluid as a Lubricant |
title_short | Electromagnetic Linear Vibration Energy Harvester Using Sliding Permanent Magnet Array and Ferrofluid as a Lubricant |
title_sort | electromagnetic linear vibration energy harvester using sliding permanent magnet array and ferrofluid as a lubricant |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189813/ https://www.ncbi.nlm.nih.gov/pubmed/30400478 http://dx.doi.org/10.3390/mi8100288 |
work_keys_str_mv | AT chaesonghee electromagneticlinearvibrationenergyharvesterusingslidingpermanentmagnetarrayandferrofluidasalubricant AT jusuna electromagneticlinearvibrationenergyharvesterusingslidingpermanentmagnetarrayandferrofluidasalubricant AT choiyunhee electromagneticlinearvibrationenergyharvesterusingslidingpermanentmagnetarrayandferrofluidasalubricant AT chiyeeun electromagneticlinearvibrationenergyharvesterusingslidingpermanentmagnetarrayandferrofluidasalubricant AT jichanghyeon electromagneticlinearvibrationenergyharvesterusingslidingpermanentmagnetarrayandferrofluidasalubricant |