Cargando…
Comprehensive Calibration of Strap-Down Tri-Axis Accelerometer Unit
This paper proposes a comprehensive calibration method to improve the precision of a strap-down tri-axis accelerometer unit, in which parameters are divided into static and dynamic ones. The contribution of the manuscript is that it solves the problem of inappropriate installation and the size effec...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189837/ http://dx.doi.org/10.3390/mi8030068 |
Sumario: | This paper proposes a comprehensive calibration method to improve the precision of a strap-down tri-axis accelerometer unit, in which parameters are divided into static and dynamic ones. The contribution of the manuscript is that it solves the problem of inappropriate installation and the size effect error for tri-axis accelerometer unit at high speed by using static and dynamic calibration method, respectively. The experiment results show the measuring accuracy of accelerometers is increased by more than one order of magnitude, and the navigation precision is increased by more than two orders of magnitude. |
---|