Cargando…

Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD

Spinning-disc interferometry (SDI) is a high-speed laser scanning approach to surface metrology that uses common-path interferometry to measure protein spots on a BioCD disk. The measurement sensitivity depends on the scanning pitch and on the time-base. Based on high-resolution laser scanning image...

Descripción completa

Detalles Bibliográficos
Autores principales: O’Brien, Kevin, Zhao, Ming, Nolte, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6190026/
https://www.ncbi.nlm.nih.gov/pubmed/30407404
http://dx.doi.org/10.3390/mi7020031
_version_ 1783363482370965504
author O’Brien, Kevin
Zhao, Ming
Nolte, David
author_facet O’Brien, Kevin
Zhao, Ming
Nolte, David
author_sort O’Brien, Kevin
collection PubMed
description Spinning-disc interferometry (SDI) is a high-speed laser scanning approach to surface metrology that uses common-path interferometry to measure protein spots on a BioCD disk. The measurement sensitivity depends on the scanning pitch and on the time-base. Based on high-resolution laser scanning images of printed antibody spots, we quantify the protein sensitivity as a function of the scan parameters. For smoothly printed antibody spots scanned with a transverse spatial resolution of 1 μm, the surface height precision for a single 100 μm diameter protein spot is approximately 1 pm. This detection sensitivity sets the fundamental limit of detection for label-free BioCD biosensors performing immunoassays.
format Online
Article
Text
id pubmed-6190026
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61900262018-11-01 Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD O’Brien, Kevin Zhao, Ming Nolte, David Micromachines (Basel) Article Spinning-disc interferometry (SDI) is a high-speed laser scanning approach to surface metrology that uses common-path interferometry to measure protein spots on a BioCD disk. The measurement sensitivity depends on the scanning pitch and on the time-base. Based on high-resolution laser scanning images of printed antibody spots, we quantify the protein sensitivity as a function of the scan parameters. For smoothly printed antibody spots scanned with a transverse spatial resolution of 1 μm, the surface height precision for a single 100 μm diameter protein spot is approximately 1 pm. This detection sensitivity sets the fundamental limit of detection for label-free BioCD biosensors performing immunoassays. MDPI 2016-02-17 /pmc/articles/PMC6190026/ /pubmed/30407404 http://dx.doi.org/10.3390/mi7020031 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
O’Brien, Kevin
Zhao, Ming
Nolte, David
Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD
title Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD
title_full Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD
title_fullStr Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD
title_full_unstemmed Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD
title_short Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD
title_sort height resolution of antibody spots measured by spinning-disk interferometry on the biocd
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6190026/
https://www.ncbi.nlm.nih.gov/pubmed/30407404
http://dx.doi.org/10.3390/mi7020031
work_keys_str_mv AT obrienkevin heightresolutionofantibodyspotsmeasuredbyspinningdiskinterferometryonthebiocd
AT zhaoming heightresolutionofantibodyspotsmeasuredbyspinningdiskinterferometryonthebiocd
AT noltedavid heightresolutionofantibodyspotsmeasuredbyspinningdiskinterferometryonthebiocd