Cargando…

Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process

Electroformed microfluidic chip mold faces the problem of uneven thickness, which decreases the dimensional accuracy of the mold, and increases the production cost. To fabricate a mold with uniform thickness, two methods are investigated. Firstly, experiments are carried out to study how the ultraso...

Descripción completa

Detalles Bibliográficos
Autores principales: Du, Liqun, Yang, Tong, Zhao, Ming, Tao, Yousheng, Luo, Lei, Wang, Lei, Liu, Chong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6190208/
https://www.ncbi.nlm.nih.gov/pubmed/30407379
http://dx.doi.org/10.3390/mi7010007
_version_ 1783363518090706944
author Du, Liqun
Yang, Tong
Zhao, Ming
Tao, Yousheng
Luo, Lei
Wang, Lei
Liu, Chong
author_facet Du, Liqun
Yang, Tong
Zhao, Ming
Tao, Yousheng
Luo, Lei
Wang, Lei
Liu, Chong
author_sort Du, Liqun
collection PubMed
description Electroformed microfluidic chip mold faces the problem of uneven thickness, which decreases the dimensional accuracy of the mold, and increases the production cost. To fabricate a mold with uniform thickness, two methods are investigated. Firstly, experiments are carried out to study how the ultrasonic agitation affects the thickness uniformity of the mold. It is found that the thickness uniformity is maximally improved by about 30% after 2 h electroforming under 200 kHz and 500 W ultrasonic agitation. Secondly, adding a second cathode, a method suitable for long-time electroforming is studied by numerical simulation. The simulation results show that with a 4 mm width second cathode used, the thickness uniformity is improved by about 30% after 2 h of electroforming, and that with electroforming time extended, the thickness uniformity is improved more obviously. After 22 h electroforming, the thickness uniformity is increased by about 45%. Finally, by comparing two methods, the method of adding a second cathode is chosen, and a microfluidic chip mold is made with the help of a specially designed second cathode. The result shows that the thickness uniformity of the mold is increased by about 50%, which is in good agreement with the simulation results.
format Online
Article
Text
id pubmed-6190208
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61902082018-11-01 Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process Du, Liqun Yang, Tong Zhao, Ming Tao, Yousheng Luo, Lei Wang, Lei Liu, Chong Micromachines (Basel) Article Electroformed microfluidic chip mold faces the problem of uneven thickness, which decreases the dimensional accuracy of the mold, and increases the production cost. To fabricate a mold with uniform thickness, two methods are investigated. Firstly, experiments are carried out to study how the ultrasonic agitation affects the thickness uniformity of the mold. It is found that the thickness uniformity is maximally improved by about 30% after 2 h electroforming under 200 kHz and 500 W ultrasonic agitation. Secondly, adding a second cathode, a method suitable for long-time electroforming is studied by numerical simulation. The simulation results show that with a 4 mm width second cathode used, the thickness uniformity is improved by about 30% after 2 h of electroforming, and that with electroforming time extended, the thickness uniformity is improved more obviously. After 22 h electroforming, the thickness uniformity is increased by about 45%. Finally, by comparing two methods, the method of adding a second cathode is chosen, and a microfluidic chip mold is made with the help of a specially designed second cathode. The result shows that the thickness uniformity of the mold is increased by about 50%, which is in good agreement with the simulation results. MDPI 2016-01-13 /pmc/articles/PMC6190208/ /pubmed/30407379 http://dx.doi.org/10.3390/mi7010007 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Co mmons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Du, Liqun
Yang, Tong
Zhao, Ming
Tao, Yousheng
Luo, Lei
Wang, Lei
Liu, Chong
Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process
title Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process
title_full Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process
title_fullStr Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process
title_full_unstemmed Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process
title_short Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process
title_sort study on improving thickness uniformity of microfluidic chip mold in the electroforming process
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6190208/
https://www.ncbi.nlm.nih.gov/pubmed/30407379
http://dx.doi.org/10.3390/mi7010007
work_keys_str_mv AT duliqun studyonimprovingthicknessuniformityofmicrofluidicchipmoldintheelectroformingprocess
AT yangtong studyonimprovingthicknessuniformityofmicrofluidicchipmoldintheelectroformingprocess
AT zhaoming studyonimprovingthicknessuniformityofmicrofluidicchipmoldintheelectroformingprocess
AT taoyousheng studyonimprovingthicknessuniformityofmicrofluidicchipmoldintheelectroformingprocess
AT luolei studyonimprovingthicknessuniformityofmicrofluidicchipmoldintheelectroformingprocess
AT wanglei studyonimprovingthicknessuniformityofmicrofluidicchipmoldintheelectroformingprocess
AT liuchong studyonimprovingthicknessuniformityofmicrofluidicchipmoldintheelectroformingprocess