Cargando…

Numerical Model of Streaming DEP for Stem Cell Sorting

Neural stem cells are of special interest due to their potential in neurogenesis to treat spinal cord injuries and other nervous disorders. Flow cytometry, a common technique used for cell sorting, is limited due to the lack of antigens and labels that are specific enough to stem cells of interest....

Descripción completa

Detalles Bibliográficos
Autores principales: Natu, Rucha, Martinez-Duarte, Rodrigo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6190341/
https://www.ncbi.nlm.nih.gov/pubmed/30404388
http://dx.doi.org/10.3390/mi7120217
_version_ 1783363547745484800
author Natu, Rucha
Martinez-Duarte, Rodrigo
author_facet Natu, Rucha
Martinez-Duarte, Rodrigo
author_sort Natu, Rucha
collection PubMed
description Neural stem cells are of special interest due to their potential in neurogenesis to treat spinal cord injuries and other nervous disorders. Flow cytometry, a common technique used for cell sorting, is limited due to the lack of antigens and labels that are specific enough to stem cells of interest. Dielectrophoresis (DEP) is a label-free separation technique that has been recently demonstrated for the enrichment of neural stem/progenitor cells. Here we use numerical simulation to investigate the use of streaming DEP for the continuous sorting of neural stem/progenitor cells. Streaming DEP refers to the focusing of cells into streams by equilibrating the dielectrophoresis and drag forces acting on them. The width of the stream should be maximized to increase throughput while the separation between streams must be widened to increase efficiency during retrieval. The aim is to understand how device geometry and experimental variables affect the throughput and efficiency of continuous sorting of SC27 stem cells, a neurogenic progenitor, from SC23 cells, an astrogenic progenitor. We define efficiency as the ratio between the number of SC27 cells over total number of cells retrieved in the streams, and throughput as the number of SC27 cells retrieved in the streams compared to their total number introduced to the device. The use of cylindrical electrodes as tall as the channel yields streams featuring >98% of SC27 cells and width up to 80 µm when using a flow rate of 10 µL/min and sample cell concentration up to 10(5) cells/mL.
format Online
Article
Text
id pubmed-6190341
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61903412018-11-01 Numerical Model of Streaming DEP for Stem Cell Sorting Natu, Rucha Martinez-Duarte, Rodrigo Micromachines (Basel) Article Neural stem cells are of special interest due to their potential in neurogenesis to treat spinal cord injuries and other nervous disorders. Flow cytometry, a common technique used for cell sorting, is limited due to the lack of antigens and labels that are specific enough to stem cells of interest. Dielectrophoresis (DEP) is a label-free separation technique that has been recently demonstrated for the enrichment of neural stem/progenitor cells. Here we use numerical simulation to investigate the use of streaming DEP for the continuous sorting of neural stem/progenitor cells. Streaming DEP refers to the focusing of cells into streams by equilibrating the dielectrophoresis and drag forces acting on them. The width of the stream should be maximized to increase throughput while the separation between streams must be widened to increase efficiency during retrieval. The aim is to understand how device geometry and experimental variables affect the throughput and efficiency of continuous sorting of SC27 stem cells, a neurogenic progenitor, from SC23 cells, an astrogenic progenitor. We define efficiency as the ratio between the number of SC27 cells over total number of cells retrieved in the streams, and throughput as the number of SC27 cells retrieved in the streams compared to their total number introduced to the device. The use of cylindrical electrodes as tall as the channel yields streams featuring >98% of SC27 cells and width up to 80 µm when using a flow rate of 10 µL/min and sample cell concentration up to 10(5) cells/mL. MDPI 2016-11-30 /pmc/articles/PMC6190341/ /pubmed/30404388 http://dx.doi.org/10.3390/mi7120217 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Natu, Rucha
Martinez-Duarte, Rodrigo
Numerical Model of Streaming DEP for Stem Cell Sorting
title Numerical Model of Streaming DEP for Stem Cell Sorting
title_full Numerical Model of Streaming DEP for Stem Cell Sorting
title_fullStr Numerical Model of Streaming DEP for Stem Cell Sorting
title_full_unstemmed Numerical Model of Streaming DEP for Stem Cell Sorting
title_short Numerical Model of Streaming DEP for Stem Cell Sorting
title_sort numerical model of streaming dep for stem cell sorting
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6190341/
https://www.ncbi.nlm.nih.gov/pubmed/30404388
http://dx.doi.org/10.3390/mi7120217
work_keys_str_mv AT naturucha numericalmodelofstreamingdepforstemcellsorting
AT martinezduarterodrigo numericalmodelofstreamingdepforstemcellsorting