Cargando…

Microstructure-Enhanced Liquid–Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip (†)

Microfluidic system is widely employed in the detection of environmental contaminants and biological specimens. One of the critical issues which limits the applications of microfluidic chips is the limit of detection of trace specimens. Liquid–liquid extraction is of great importance in the preproce...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiong, Penghui, Chen, Xiangyu, Xiong, Ying, Liu, Gang, Tian, Yangchao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6190443/
https://www.ncbi.nlm.nih.gov/pubmed/30407418
http://dx.doi.org/10.3390/mi7030046
_version_ 1783363572169965568
author Xiong, Penghui
Chen, Xiangyu
Xiong, Ying
Liu, Gang
Tian, Yangchao
author_facet Xiong, Penghui
Chen, Xiangyu
Xiong, Ying
Liu, Gang
Tian, Yangchao
author_sort Xiong, Penghui
collection PubMed
description Microfluidic system is widely employed in the detection of environmental contaminants and biological specimens. One of the critical issues which limits the applications of microfluidic chips is the limit of detection of trace specimens. Liquid–liquid extraction is of great importance in the preprocessing in microfluidic devices. In this paper, we developed a real-time fluorescence detection microfluidic chip combined with a microstructure-enhanced liquid–liquid laminar extraction technique, which concentrated the trace compound and realized real-time monitoring. Auxiliary microstructures integrated in the microfluidic chip were applied to increase the extraction efficiency, which was proved by the FEM (finite element method) simulation as well. A common fluorescence probe, Rhodamine 6G (Rh6g), was used in the experiment to demonstrate the performance of the microfluidic system. It revealed that the liquid–liquid laminar extraction combined with auxiliary microstructures of a cross shape was an effective method for enrichment. The efficiency of microstructure-enhanced liquid–liquid extraction was increased by 350% compared to the traditional laminar flow extraction.
format Online
Article
Text
id pubmed-6190443
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61904432018-11-01 Microstructure-Enhanced Liquid–Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip (†) Xiong, Penghui Chen, Xiangyu Xiong, Ying Liu, Gang Tian, Yangchao Micromachines (Basel) Article Microfluidic system is widely employed in the detection of environmental contaminants and biological specimens. One of the critical issues which limits the applications of microfluidic chips is the limit of detection of trace specimens. Liquid–liquid extraction is of great importance in the preprocessing in microfluidic devices. In this paper, we developed a real-time fluorescence detection microfluidic chip combined with a microstructure-enhanced liquid–liquid laminar extraction technique, which concentrated the trace compound and realized real-time monitoring. Auxiliary microstructures integrated in the microfluidic chip were applied to increase the extraction efficiency, which was proved by the FEM (finite element method) simulation as well. A common fluorescence probe, Rhodamine 6G (Rh6g), was used in the experiment to demonstrate the performance of the microfluidic system. It revealed that the liquid–liquid laminar extraction combined with auxiliary microstructures of a cross shape was an effective method for enrichment. The efficiency of microstructure-enhanced liquid–liquid extraction was increased by 350% compared to the traditional laminar flow extraction. MDPI 2016-03-10 /pmc/articles/PMC6190443/ /pubmed/30407418 http://dx.doi.org/10.3390/mi7030046 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xiong, Penghui
Chen, Xiangyu
Xiong, Ying
Liu, Gang
Tian, Yangchao
Microstructure-Enhanced Liquid–Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip (†)
title Microstructure-Enhanced Liquid–Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip (†)
title_full Microstructure-Enhanced Liquid–Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip (†)
title_fullStr Microstructure-Enhanced Liquid–Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip (†)
title_full_unstemmed Microstructure-Enhanced Liquid–Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip (†)
title_short Microstructure-Enhanced Liquid–Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip (†)
title_sort microstructure-enhanced liquid–liquid extraction in a real-time fluorescence detection microfluidic chip (†)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6190443/
https://www.ncbi.nlm.nih.gov/pubmed/30407418
http://dx.doi.org/10.3390/mi7030046
work_keys_str_mv AT xiongpenghui microstructureenhancedliquidliquidextractioninarealtimefluorescencedetectionmicrofluidicchip
AT chenxiangyu microstructureenhancedliquidliquidextractioninarealtimefluorescencedetectionmicrofluidicchip
AT xiongying microstructureenhancedliquidliquidextractioninarealtimefluorescencedetectionmicrofluidicchip
AT liugang microstructureenhancedliquidliquidextractioninarealtimefluorescencedetectionmicrofluidicchip
AT tianyangchao microstructureenhancedliquidliquidextractioninarealtimefluorescencedetectionmicrofluidicchip