Cargando…

Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study

PURPOSE: Myocardial computed tomography perfusion (CTP) allows the assessment of the functional relevance of coronary artery stenosis. This study investigates to what extent the contour sharpness of sequences acquired by dynamic myocardial CTP is influenced by the following noise reduction methods:...

Descripción completa

Detalles Bibliográficos
Autores principales: Feger, Sarah, Kendziorra, Carsten, Lukas, Steffen, Shaban, Ahmed, Bokelmann, Björn, Zimmermann, Elke, Rief, Matthias, Dewey, Marc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6191149/
https://www.ncbi.nlm.nih.gov/pubmed/30325969
http://dx.doi.org/10.1371/journal.pone.0205922
_version_ 1783363673165660160
author Feger, Sarah
Kendziorra, Carsten
Lukas, Steffen
Shaban, Ahmed
Bokelmann, Björn
Zimmermann, Elke
Rief, Matthias
Dewey, Marc
author_facet Feger, Sarah
Kendziorra, Carsten
Lukas, Steffen
Shaban, Ahmed
Bokelmann, Björn
Zimmermann, Elke
Rief, Matthias
Dewey, Marc
author_sort Feger, Sarah
collection PubMed
description PURPOSE: Myocardial computed tomography perfusion (CTP) allows the assessment of the functional relevance of coronary artery stenosis. This study investigates to what extent the contour sharpness of sequences acquired by dynamic myocardial CTP is influenced by the following noise reduction methods: temporal averaging and adaptive iterative dose reduction 3D (AIDR 3D). MATERIALS AND METHODS: Dynamic myocardial CT perfusion was conducted in 29 patients at a dose level of 9.5±2.0 mSv and was reconstructed with both filtered back projection (FBP) and strong levels of AIDR 3D. Temporal averaging to reduce noise was performed as a post-processing step by combining two, three, four, six and eight original consecutive 3D datasets. We evaluated the contour sharpness at four distinct edges of the left-ventricular myocardium based on two different approaches: the distance between 25% and 75% of the maximal grey value (d) and the slope in the contour (m). RESULTS: Iterative reconstruction reduced contour sharpness: both measures of contour sharpness performed better for FBP than for AIDR 3D (d = 1.7±0.4 mm versus 2.0±0.5 mm, p>0.059 at all edges; m = 255.9±123.9 HU/mm versus 160.6±123.5 HU/mm; p<0.023 for all edges). Increasing levels of temporal averaging degraded contour sharpness. When FBP reconstruction was applied, contour sharpness was best without temporal averaging (d = 1.7±0.4 mm, m = 255.9±123.9 HU/mm) and poorest for the strongest levels of temporal averaging (d = 2.1±0.3 mm, m = 142.2±104.9 HU/mm; comparison between lowest and highest temporal averaging level: for d p>0.052 at all edges and for m p<0.001 at all edges). CONCLUSION: The use of both temporal averaging and iterative reconstruction degrades objective contour sharpness parameters of dynamic myocardial CTP. Thus, further advances in image processing are needed to optimise contour sharpness of 4D myocardial CTP.
format Online
Article
Text
id pubmed-6191149
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61911492018-10-25 Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study Feger, Sarah Kendziorra, Carsten Lukas, Steffen Shaban, Ahmed Bokelmann, Björn Zimmermann, Elke Rief, Matthias Dewey, Marc PLoS One Research Article PURPOSE: Myocardial computed tomography perfusion (CTP) allows the assessment of the functional relevance of coronary artery stenosis. This study investigates to what extent the contour sharpness of sequences acquired by dynamic myocardial CTP is influenced by the following noise reduction methods: temporal averaging and adaptive iterative dose reduction 3D (AIDR 3D). MATERIALS AND METHODS: Dynamic myocardial CT perfusion was conducted in 29 patients at a dose level of 9.5±2.0 mSv and was reconstructed with both filtered back projection (FBP) and strong levels of AIDR 3D. Temporal averaging to reduce noise was performed as a post-processing step by combining two, three, four, six and eight original consecutive 3D datasets. We evaluated the contour sharpness at four distinct edges of the left-ventricular myocardium based on two different approaches: the distance between 25% and 75% of the maximal grey value (d) and the slope in the contour (m). RESULTS: Iterative reconstruction reduced contour sharpness: both measures of contour sharpness performed better for FBP than for AIDR 3D (d = 1.7±0.4 mm versus 2.0±0.5 mm, p>0.059 at all edges; m = 255.9±123.9 HU/mm versus 160.6±123.5 HU/mm; p<0.023 for all edges). Increasing levels of temporal averaging degraded contour sharpness. When FBP reconstruction was applied, contour sharpness was best without temporal averaging (d = 1.7±0.4 mm, m = 255.9±123.9 HU/mm) and poorest for the strongest levels of temporal averaging (d = 2.1±0.3 mm, m = 142.2±104.9 HU/mm; comparison between lowest and highest temporal averaging level: for d p>0.052 at all edges and for m p<0.001 at all edges). CONCLUSION: The use of both temporal averaging and iterative reconstruction degrades objective contour sharpness parameters of dynamic myocardial CTP. Thus, further advances in image processing are needed to optimise contour sharpness of 4D myocardial CTP. Public Library of Science 2018-10-16 /pmc/articles/PMC6191149/ /pubmed/30325969 http://dx.doi.org/10.1371/journal.pone.0205922 Text en © 2018 Feger et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Feger, Sarah
Kendziorra, Carsten
Lukas, Steffen
Shaban, Ahmed
Bokelmann, Björn
Zimmermann, Elke
Rief, Matthias
Dewey, Marc
Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study
title Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study
title_full Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study
title_fullStr Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study
title_full_unstemmed Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study
title_short Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study
title_sort effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial ct perfusion: sub-analysis of the prospective 4d ct perfusion pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6191149/
https://www.ncbi.nlm.nih.gov/pubmed/30325969
http://dx.doi.org/10.1371/journal.pone.0205922
work_keys_str_mv AT fegersarah effectofiterativereconstructionandtemporalaveragingoncontoursharpnessindynamicmyocardialctperfusionsubanalysisoftheprospective4dctperfusionpilotstudy
AT kendziorracarsten effectofiterativereconstructionandtemporalaveragingoncontoursharpnessindynamicmyocardialctperfusionsubanalysisoftheprospective4dctperfusionpilotstudy
AT lukassteffen effectofiterativereconstructionandtemporalaveragingoncontoursharpnessindynamicmyocardialctperfusionsubanalysisoftheprospective4dctperfusionpilotstudy
AT shabanahmed effectofiterativereconstructionandtemporalaveragingoncontoursharpnessindynamicmyocardialctperfusionsubanalysisoftheprospective4dctperfusionpilotstudy
AT bokelmannbjorn effectofiterativereconstructionandtemporalaveragingoncontoursharpnessindynamicmyocardialctperfusionsubanalysisoftheprospective4dctperfusionpilotstudy
AT zimmermannelke effectofiterativereconstructionandtemporalaveragingoncontoursharpnessindynamicmyocardialctperfusionsubanalysisoftheprospective4dctperfusionpilotstudy
AT riefmatthias effectofiterativereconstructionandtemporalaveragingoncontoursharpnessindynamicmyocardialctperfusionsubanalysisoftheprospective4dctperfusionpilotstudy
AT deweymarc effectofiterativereconstructionandtemporalaveragingoncontoursharpnessindynamicmyocardialctperfusionsubanalysisoftheprospective4dctperfusionpilotstudy