Cargando…

The Expanding Role of Diagnostic Ultrasound in Plastic Surgery

BACKGROUND: Ultrasound in plastic surgery is quickly finding new applications. Ultrasound surveillance may replace ineffective individual risk stratification and chemoprophylaxis for deep venous thromboses. Abdominal penetration can be a catastrophic complication of liposuction. Preoperative screeni...

Descripción completa

Detalles Bibliográficos
Autor principal: Swanson, Eric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6191221/
https://www.ncbi.nlm.nih.gov/pubmed/30349786
http://dx.doi.org/10.1097/GOX.0000000000001911
_version_ 1783363682995011584
author Swanson, Eric
author_facet Swanson, Eric
author_sort Swanson, Eric
collection PubMed
description BACKGROUND: Ultrasound in plastic surgery is quickly finding new applications. Ultrasound surveillance may replace ineffective individual risk stratification and chemoprophylaxis for deep venous thromboses. Abdominal penetration can be a catastrophic complication of liposuction. Preoperative screening for fascial defects may reduce risk. Limiting buttock fat injections to the subcutaneous plane is critical for patient safety, but it is difficult to know one’s injection plane. METHODS: The author’s use of diagnostic ultrasound was evaluated from May 2017 to May 2018. Ultrasound scans were used routinely to detect deep venous thromboses. Patients undergoing abdominal liposuction and/or abdominoplasty were scanned for possible hernias. Other common applications included the evaluation of breast implants, breast masses, and seroma management. The device was used in surgery in 3 patients to assess the plane of buttock fat injection. RESULTS: One thousand ultrasound scans were performed during the 1-year study period. A distal deep venous thrombosis was detected in 2 patients. In both cases, the thrombosis resolved within 1 month, confirmed by follow-up ultrasound scans. A lateral (tangential) fat injection method was shown to safely deposit fat above the gluteus maximus fascia. CONCLUSIONS: Ultrasound scans are highly accurate, noninvasive, and well-tolerated by patients. Some of these applications are likely to improve patient safety. Early detection of deep venous thromboses is possible. Unnecessary anticoagulation may be avoided. Subclinical abdominal defects may be detected. Ultrasound may be used in the office to evaluate breast implants, masses, and seromas. In surgery, this device confirms the level of buttock fat injection.
format Online
Article
Text
id pubmed-6191221
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-61912212018-10-22 The Expanding Role of Diagnostic Ultrasound in Plastic Surgery Swanson, Eric Plast Reconstr Surg Glob Open Special Topic BACKGROUND: Ultrasound in plastic surgery is quickly finding new applications. Ultrasound surveillance may replace ineffective individual risk stratification and chemoprophylaxis for deep venous thromboses. Abdominal penetration can be a catastrophic complication of liposuction. Preoperative screening for fascial defects may reduce risk. Limiting buttock fat injections to the subcutaneous plane is critical for patient safety, but it is difficult to know one’s injection plane. METHODS: The author’s use of diagnostic ultrasound was evaluated from May 2017 to May 2018. Ultrasound scans were used routinely to detect deep venous thromboses. Patients undergoing abdominal liposuction and/or abdominoplasty were scanned for possible hernias. Other common applications included the evaluation of breast implants, breast masses, and seroma management. The device was used in surgery in 3 patients to assess the plane of buttock fat injection. RESULTS: One thousand ultrasound scans were performed during the 1-year study period. A distal deep venous thrombosis was detected in 2 patients. In both cases, the thrombosis resolved within 1 month, confirmed by follow-up ultrasound scans. A lateral (tangential) fat injection method was shown to safely deposit fat above the gluteus maximus fascia. CONCLUSIONS: Ultrasound scans are highly accurate, noninvasive, and well-tolerated by patients. Some of these applications are likely to improve patient safety. Early detection of deep venous thromboses is possible. Unnecessary anticoagulation may be avoided. Subclinical abdominal defects may be detected. Ultrasound may be used in the office to evaluate breast implants, masses, and seromas. In surgery, this device confirms the level of buttock fat injection. Wolters Kluwer Health 2018-09-05 /pmc/articles/PMC6191221/ /pubmed/30349786 http://dx.doi.org/10.1097/GOX.0000000000001911 Text en Copyright © 2018 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of The American Society of Plastic Surgeons. This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Special Topic
Swanson, Eric
The Expanding Role of Diagnostic Ultrasound in Plastic Surgery
title The Expanding Role of Diagnostic Ultrasound in Plastic Surgery
title_full The Expanding Role of Diagnostic Ultrasound in Plastic Surgery
title_fullStr The Expanding Role of Diagnostic Ultrasound in Plastic Surgery
title_full_unstemmed The Expanding Role of Diagnostic Ultrasound in Plastic Surgery
title_short The Expanding Role of Diagnostic Ultrasound in Plastic Surgery
title_sort expanding role of diagnostic ultrasound in plastic surgery
topic Special Topic
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6191221/
https://www.ncbi.nlm.nih.gov/pubmed/30349786
http://dx.doi.org/10.1097/GOX.0000000000001911
work_keys_str_mv AT swansoneric theexpandingroleofdiagnosticultrasoundinplasticsurgery
AT swansoneric expandingroleofdiagnosticultrasoundinplasticsurgery