Combined association of liver and renal injury by intra-aortic balloon pump malposition
BACKGROUND: We report an unusual visceral complication of intra-aortic balloon pump (IABP) due to the malpositioning of the catheter in the aorta. CASE REPORT: A 55-year-old man with severe left ventricular dysfunction underwent coronary artery bypass grafting (CABG) with the preoperative use of an...