Cargando…

Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults

Effective management of neurogenic orthostatic hypotension and supine hypertension (SH-OH) due autonomic failure requires a frequent and timely adjustment of medication throughout the day to maintain the blood pressure (BP) within the normal range, i.e., an accurate depiction of BP is a key prerequi...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6193524/
https://www.ncbi.nlm.nih.gov/pubmed/30345183
http://dx.doi.org/10.1109/JTEHM.2018.2864738
_version_ 1783364076762562560
collection PubMed
description Effective management of neurogenic orthostatic hypotension and supine hypertension (SH-OH) due autonomic failure requires a frequent and timely adjustment of medication throughout the day to maintain the blood pressure (BP) within the normal range, i.e., an accurate depiction of BP is a key prerequisite of effective management. One of the emerging technologies that provide one’s circadian and long-term physiological status with increased usability is unobtrusive zero-effort monitoring. In this paper, a zero-effort device, a floor tile, was used to develop an unobtrusive BP monitoring technique. Namely, RJ-interval, the time between the J-peak of a ballistocardiogram and the R-peak of an electrocardiogram, was used to develop a classifier that can detect changes in systolic BP (SBP) induced by the Valsalva maneuver on healthy adults (i.e., a simulated SH-OH). A t-test was used to show statistical differences between the mean RJ-intervals of decreased SBP, baseline, and increased SBP. Following the t-test, a classifier that detected a change in SBP was developed based on a naïve Bayes classifier (NBC). The t-test showed a clear statistical difference between the mean RJ-intervals of the increased SBP, baseline, and decreased SBP. The NBC-based classifier was able to detect increased SBP with 89.3% true positive rate (TPR), 100% true negative rate (TNR), and 94% accuracy and detect decreased SBP with 92.3% TPR, 100% TNR, and 95% accuracy. The analysis showed strong potential in using the developed classifier to assist monitoring of people with SH-OH; the algorithm may be used clinically to detect a long-term trend of symptoms of SH-OH.
format Online
Article
Text
id pubmed-6193524
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-61935242018-10-19 Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults IEEE J Transl Eng Health Med Article Effective management of neurogenic orthostatic hypotension and supine hypertension (SH-OH) due autonomic failure requires a frequent and timely adjustment of medication throughout the day to maintain the blood pressure (BP) within the normal range, i.e., an accurate depiction of BP is a key prerequisite of effective management. One of the emerging technologies that provide one’s circadian and long-term physiological status with increased usability is unobtrusive zero-effort monitoring. In this paper, a zero-effort device, a floor tile, was used to develop an unobtrusive BP monitoring technique. Namely, RJ-interval, the time between the J-peak of a ballistocardiogram and the R-peak of an electrocardiogram, was used to develop a classifier that can detect changes in systolic BP (SBP) induced by the Valsalva maneuver on healthy adults (i.e., a simulated SH-OH). A t-test was used to show statistical differences between the mean RJ-intervals of decreased SBP, baseline, and increased SBP. Following the t-test, a classifier that detected a change in SBP was developed based on a naïve Bayes classifier (NBC). The t-test showed a clear statistical difference between the mean RJ-intervals of the increased SBP, baseline, and decreased SBP. The NBC-based classifier was able to detect increased SBP with 89.3% true positive rate (TPR), 100% true negative rate (TNR), and 94% accuracy and detect decreased SBP with 92.3% TPR, 100% TNR, and 95% accuracy. The analysis showed strong potential in using the developed classifier to assist monitoring of people with SH-OH; the algorithm may be used clinically to detect a long-term trend of symptoms of SH-OH. IEEE 2018-10-17 /pmc/articles/PMC6193524/ /pubmed/30345183 http://dx.doi.org/10.1109/JTEHM.2018.2864738 Text en 2168-2372 © 2018 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
spellingShingle Article
Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults
title Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults
title_full Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults
title_fullStr Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults
title_full_unstemmed Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults
title_short Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults
title_sort unobtrusive detection of simulated orthostatic hypotension and supine hypertension using ballistocardiogram and electrocardiogram of healthy adults
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6193524/
https://www.ncbi.nlm.nih.gov/pubmed/30345183
http://dx.doi.org/10.1109/JTEHM.2018.2864738
work_keys_str_mv AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults
AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults
AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults
AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults
AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults