Cargando…
Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults
Effective management of neurogenic orthostatic hypotension and supine hypertension (SH-OH) due autonomic failure requires a frequent and timely adjustment of medication throughout the day to maintain the blood pressure (BP) within the normal range, i.e., an accurate depiction of BP is a key prerequi...
Formato: | Online Artículo Texto |
---|---|
Lenguaje: | English |
Publicado: |
IEEE
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6193524/ https://www.ncbi.nlm.nih.gov/pubmed/30345183 http://dx.doi.org/10.1109/JTEHM.2018.2864738 |
_version_ | 1783364076762562560 |
---|---|
collection | PubMed |
description | Effective management of neurogenic orthostatic hypotension and supine hypertension (SH-OH) due autonomic failure requires a frequent and timely adjustment of medication throughout the day to maintain the blood pressure (BP) within the normal range, i.e., an accurate depiction of BP is a key prerequisite of effective management. One of the emerging technologies that provide one’s circadian and long-term physiological status with increased usability is unobtrusive zero-effort monitoring. In this paper, a zero-effort device, a floor tile, was used to develop an unobtrusive BP monitoring technique. Namely, RJ-interval, the time between the J-peak of a ballistocardiogram and the R-peak of an electrocardiogram, was used to develop a classifier that can detect changes in systolic BP (SBP) induced by the Valsalva maneuver on healthy adults (i.e., a simulated SH-OH). A t-test was used to show statistical differences between the mean RJ-intervals of decreased SBP, baseline, and increased SBP. Following the t-test, a classifier that detected a change in SBP was developed based on a naïve Bayes classifier (NBC). The t-test showed a clear statistical difference between the mean RJ-intervals of the increased SBP, baseline, and decreased SBP. The NBC-based classifier was able to detect increased SBP with 89.3% true positive rate (TPR), 100% true negative rate (TNR), and 94% accuracy and detect decreased SBP with 92.3% TPR, 100% TNR, and 95% accuracy. The analysis showed strong potential in using the developed classifier to assist monitoring of people with SH-OH; the algorithm may be used clinically to detect a long-term trend of symptoms of SH-OH. |
format | Online Article Text |
id | pubmed-6193524 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | IEEE |
record_format | MEDLINE/PubMed |
spelling | pubmed-61935242018-10-19 Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults IEEE J Transl Eng Health Med Article Effective management of neurogenic orthostatic hypotension and supine hypertension (SH-OH) due autonomic failure requires a frequent and timely adjustment of medication throughout the day to maintain the blood pressure (BP) within the normal range, i.e., an accurate depiction of BP is a key prerequisite of effective management. One of the emerging technologies that provide one’s circadian and long-term physiological status with increased usability is unobtrusive zero-effort monitoring. In this paper, a zero-effort device, a floor tile, was used to develop an unobtrusive BP monitoring technique. Namely, RJ-interval, the time between the J-peak of a ballistocardiogram and the R-peak of an electrocardiogram, was used to develop a classifier that can detect changes in systolic BP (SBP) induced by the Valsalva maneuver on healthy adults (i.e., a simulated SH-OH). A t-test was used to show statistical differences between the mean RJ-intervals of decreased SBP, baseline, and increased SBP. Following the t-test, a classifier that detected a change in SBP was developed based on a naïve Bayes classifier (NBC). The t-test showed a clear statistical difference between the mean RJ-intervals of the increased SBP, baseline, and decreased SBP. The NBC-based classifier was able to detect increased SBP with 89.3% true positive rate (TPR), 100% true negative rate (TNR), and 94% accuracy and detect decreased SBP with 92.3% TPR, 100% TNR, and 95% accuracy. The analysis showed strong potential in using the developed classifier to assist monitoring of people with SH-OH; the algorithm may be used clinically to detect a long-term trend of symptoms of SH-OH. IEEE 2018-10-17 /pmc/articles/PMC6193524/ /pubmed/30345183 http://dx.doi.org/10.1109/JTEHM.2018.2864738 Text en 2168-2372 © 2018 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information. |
spellingShingle | Article Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults |
title | Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults |
title_full | Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults |
title_fullStr | Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults |
title_full_unstemmed | Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults |
title_short | Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults |
title_sort | unobtrusive detection of simulated orthostatic hypotension and supine hypertension using ballistocardiogram and electrocardiogram of healthy adults |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6193524/ https://www.ncbi.nlm.nih.gov/pubmed/30345183 http://dx.doi.org/10.1109/JTEHM.2018.2864738 |
work_keys_str_mv | AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults AT unobtrusivedetectionofsimulatedorthostatichypotensionandsupinehypertensionusingballistocardiogramandelectrocardiogramofhealthyadults |