Cargando…
Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report
An 85-year-old woman developed severe swelling and pain in the proximal thigh after internal fixation of an intertrochanteric fracture of the femur with a hip nail. In order to identify the causes and determine the effective treatment, angiography was performed. The results of the angiography reveal...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Turkish Association of Orthopaedics and Traumatology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6197181/ https://www.ncbi.nlm.nih.gov/pubmed/28457795 http://dx.doi.org/10.1016/j.aott.2017.03.011 |
_version_ | 1783364707758899200 |
---|---|
author | Kim, Ji Wan Lee, Jung Il Park, Ki Chul |
author_facet | Kim, Ji Wan Lee, Jung Il Park, Ki Chul |
author_sort | Kim, Ji Wan |
collection | PubMed |
description | An 85-year-old woman developed severe swelling and pain in the proximal thigh after internal fixation of an intertrochanteric fracture of the femur with a hip nail. In order to identify the causes and determine the effective treatment, angiography was performed. The results of the angiography revealed a pseudoaneurysm of a branch of deep femoral artery. Endovascular embolization was used to treat the pseudoaneurysm. After reviewing all possible causes, we found a mistake in insertion of a guide wire for hip nail. Using intraoperative fluoroscopic images, we found the mal-positioned guide wire located posterior to trochanter on lateral view of hip. This case study reminds us that pseudoaneurysm can occur in a guide wire during hip nailing. Surgeons can avoid this complication with confirmation of lateral and anteroposterior view of hip. |
format | Online Article Text |
id | pubmed-6197181 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Turkish Association of Orthopaedics and Traumatology |
record_format | MEDLINE/PubMed |
spelling | pubmed-61971812018-10-24 Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report Kim, Ji Wan Lee, Jung Il Park, Ki Chul Acta Orthop Traumatol Turc Case Report An 85-year-old woman developed severe swelling and pain in the proximal thigh after internal fixation of an intertrochanteric fracture of the femur with a hip nail. In order to identify the causes and determine the effective treatment, angiography was performed. The results of the angiography revealed a pseudoaneurysm of a branch of deep femoral artery. Endovascular embolization was used to treat the pseudoaneurysm. After reviewing all possible causes, we found a mistake in insertion of a guide wire for hip nail. Using intraoperative fluoroscopic images, we found the mal-positioned guide wire located posterior to trochanter on lateral view of hip. This case study reminds us that pseudoaneurysm can occur in a guide wire during hip nailing. Surgeons can avoid this complication with confirmation of lateral and anteroposterior view of hip. Turkish Association of Orthopaedics and Traumatology 2017-05 2017-04-28 /pmc/articles/PMC6197181/ /pubmed/28457795 http://dx.doi.org/10.1016/j.aott.2017.03.011 Text en © 2017 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Kim, Ji Wan Lee, Jung Il Park, Ki Chul Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report |
title | Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report |
title_full | Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report |
title_fullStr | Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report |
title_full_unstemmed | Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report |
title_short | Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report |
title_sort | pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6197181/ https://www.ncbi.nlm.nih.gov/pubmed/28457795 http://dx.doi.org/10.1016/j.aott.2017.03.011 |
work_keys_str_mv | AT kimjiwan pseudoaneurysmofthedeepfemoralarterycausedbyaguidewirefollowingfemurintertrochantericfracturewithahipnailacasereport AT leejungil pseudoaneurysmofthedeepfemoralarterycausedbyaguidewirefollowingfemurintertrochantericfracturewithahipnailacasereport AT parkkichul pseudoaneurysmofthedeepfemoralarterycausedbyaguidewirefollowingfemurintertrochantericfracturewithahipnailacasereport |