Optimal trajectory and insertion accuracy of sacral alar iliac screws
OBJECTIVE: The aim of this study was to analyse the optimal trajectories for sacral alar iliac screws (SAISs) in a Japanese patient population and the clinical assessment of insertion accuracies. METHODS: The ideal trajectories of SAISs, starting from 2 mm medial to the apex of the lateral sacral cr...
Autores principales: | Yamada, Katsutaka, Higashi, Takayuki, Kaneko, Kanichiro, Ide, Manabu, Sekiya, Tatsuhiro, Saito, Tomoyuki |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Turkish Association of Orthopaedics and Traumatology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6197365/ https://www.ncbi.nlm.nih.gov/pubmed/28583753 http://dx.doi.org/10.1016/j.aott.2017.05.004 |
Ejemplares similares
-
Extra-articular Portion of the Sacroiliac Joint—Between the Sacral and Pelvic Tuberosities: An Anatomical Guide for the S2-Alar-Iliac Screw Trajectory
por: Tatara, Yasunori, et al.
Publicado: (2020) -
Evaluation of functional and structural leg length discrepancy in patients with adolescent idiopathic scoliosis using the EOS imaging system: a prospective comparative study
por: Sekiya, Tatsuhiro, et al.
Publicado: (2018) -
Three-Dimensional Analysis of the Ideal Entry Point for Sacral Alar Iliac Screws
por: Watanabe, Noriyuki, et al.
Publicado: (2022) -
Radiographic analysis of the sacral-2-alar screw trajectory
por: Zhao, Yulin, et al.
Publicado: (2021) -
Response to “Is the Greater Trochanter the Ideal Freehand Landmark for the S2AI Screw Angle in the Caudal Direction? Commentary on ‘Extra-Articular Portion of the Sacroiliac Joint—Between the Sacral and Pelvic Tuberosities: An Anatomical Guide for the S2-Alar-Iliac Screw Trajectory’ by Tatara et al”
por: Tatara, Yasunori, et al.
Publicado: (2021)