Cargando…
Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength
OBJECTIVE: The purpose of this study is to assess the effect and correlation of gender, body mass index (BMI) and quadriceps femoris (QF) muscle strength on patellar tendon (PT) thickness and stiffness in healthy sedentary individuals. METHODS: This study was carried out with 67 (36 female, 31 male)...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Turkish Association of Orthopaedics and Traumatology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6197583/ https://www.ncbi.nlm.nih.gov/pubmed/28010997 http://dx.doi.org/10.1016/j.aott.2016.12.003 |
_version_ | 1783364797428924416 |
---|---|
author | Taş, Serkan Yılmaz, Seval Onur, Mehmet Ruhi Soylu, Abdullah Ruhi Altuntaş, Onur Korkusuz, Feza |
author_facet | Taş, Serkan Yılmaz, Seval Onur, Mehmet Ruhi Soylu, Abdullah Ruhi Altuntaş, Onur Korkusuz, Feza |
author_sort | Taş, Serkan |
collection | PubMed |
description | OBJECTIVE: The purpose of this study is to assess the effect and correlation of gender, body mass index (BMI) and quadriceps femoris (QF) muscle strength on patellar tendon (PT) thickness and stiffness in healthy sedentary individuals. METHODS: This study was carried out with 67 (36 female, 31 male) healthy sedentary individuals between the ages of 18–44 (28.0 ± 7.5 years). The individuals included in the study were divided into two groups according to their gender and BMI (18.5 < BMI < 25 and 25 < BMI). The body composition was determined with Tanita Body Composition Analyser. PT thickness and stiffness was measured with ACUSON S3000 Ultrasonography Device using 9L4 ultrasonography probe. QF concentric muscle strength of the individuals was measured with Biodex(®) System 4 Dynamometer at 60°/sec angular speed. RESULTS: It was found that PT stiffness was higher in males compared to females (p < 0.001). It was found that PT stiffness was lower in obese individuals compared to individuals with normal weight (p = 0.017). A negative and weak correlation was found between BMI and PT stiffness (r = −0.26, p = 0.032), whereas a negative and moderate correlation was found between fat percentage and PT stiffness (r = −0.50, p < 0.001). A moderate correlation was found between BMI and PT thickness (r = 0.54, p < 0.001). It was found that peak torque at 60°/sec angular speed had a moderate correlation with PT stiffness (r = 0.44, p < 0.001) and PT thickness (r = 0.45, p < 0.001). CONCLUSIONS: PT stiffness is correlated and affected by gender, BMI and QF muscle strength whereas PT thickness is correlated and affected only to BMI and QF muscle strength. |
format | Online Article Text |
id | pubmed-6197583 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Turkish Association of Orthopaedics and Traumatology |
record_format | MEDLINE/PubMed |
spelling | pubmed-61975832018-10-25 Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength Taş, Serkan Yılmaz, Seval Onur, Mehmet Ruhi Soylu, Abdullah Ruhi Altuntaş, Onur Korkusuz, Feza Acta Orthop Traumatol Turc Original Article OBJECTIVE: The purpose of this study is to assess the effect and correlation of gender, body mass index (BMI) and quadriceps femoris (QF) muscle strength on patellar tendon (PT) thickness and stiffness in healthy sedentary individuals. METHODS: This study was carried out with 67 (36 female, 31 male) healthy sedentary individuals between the ages of 18–44 (28.0 ± 7.5 years). The individuals included in the study were divided into two groups according to their gender and BMI (18.5 < BMI < 25 and 25 < BMI). The body composition was determined with Tanita Body Composition Analyser. PT thickness and stiffness was measured with ACUSON S3000 Ultrasonography Device using 9L4 ultrasonography probe. QF concentric muscle strength of the individuals was measured with Biodex(®) System 4 Dynamometer at 60°/sec angular speed. RESULTS: It was found that PT stiffness was higher in males compared to females (p < 0.001). It was found that PT stiffness was lower in obese individuals compared to individuals with normal weight (p = 0.017). A negative and weak correlation was found between BMI and PT stiffness (r = −0.26, p = 0.032), whereas a negative and moderate correlation was found between fat percentage and PT stiffness (r = −0.50, p < 0.001). A moderate correlation was found between BMI and PT thickness (r = 0.54, p < 0.001). It was found that peak torque at 60°/sec angular speed had a moderate correlation with PT stiffness (r = 0.44, p < 0.001) and PT thickness (r = 0.45, p < 0.001). CONCLUSIONS: PT stiffness is correlated and affected by gender, BMI and QF muscle strength whereas PT thickness is correlated and affected only to BMI and QF muscle strength. Turkish Association of Orthopaedics and Traumatology 2017-01 2016-12-20 /pmc/articles/PMC6197583/ /pubmed/28010997 http://dx.doi.org/10.1016/j.aott.2016.12.003 Text en © 2016 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Taş, Serkan Yılmaz, Seval Onur, Mehmet Ruhi Soylu, Abdullah Ruhi Altuntaş, Onur Korkusuz, Feza Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength |
title | Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength |
title_full | Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength |
title_fullStr | Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength |
title_full_unstemmed | Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength |
title_short | Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength |
title_sort | patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6197583/ https://www.ncbi.nlm.nih.gov/pubmed/28010997 http://dx.doi.org/10.1016/j.aott.2016.12.003 |
work_keys_str_mv | AT tasserkan patellartendonmechanicalpropertieschangewithgenderbodymassindexandquadricepsfemorismusclestrength AT yılmazseval patellartendonmechanicalpropertieschangewithgenderbodymassindexandquadricepsfemorismusclestrength AT onurmehmetruhi patellartendonmechanicalpropertieschangewithgenderbodymassindexandquadricepsfemorismusclestrength AT soyluabdullahruhi patellartendonmechanicalpropertieschangewithgenderbodymassindexandquadricepsfemorismusclestrength AT altuntasonur patellartendonmechanicalpropertieschangewithgenderbodymassindexandquadricepsfemorismusclestrength AT korkusuzfeza patellartendonmechanicalpropertieschangewithgenderbodymassindexandquadricepsfemorismusclestrength |