Cargando…
Endovascular Coiling for a Wide-neck Bifurcated Aneurysm with Anterograde Horizontal Stenting via Microcatheter Looping: A Technical Case Report
Technical advances with devices such as catheters, balloons, and stents have widened the indications for endovascular coiling for unfavorable aneurysms. The authors report two cases of coil embolization for a wide-neck bifurcated aneurysm with anterograde horizontal stenting via microcatheter loopin...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Cerebrovascular Surgeons; Society of Korean Endovascular Neurosurgeons
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6199400/ https://www.ncbi.nlm.nih.gov/pubmed/30397590 http://dx.doi.org/10.7461/jcen.2018.20.3.181 |
_version_ | 1783365138944884736 |
---|---|
author | Jeon, Hyun-Jae Park, Jong-Hwa Lee, Jong-Young Jeon, Hong-Jun Park, Seoung-Woo Cho, Byung-Moon |
author_facet | Jeon, Hyun-Jae Park, Jong-Hwa Lee, Jong-Young Jeon, Hong-Jun Park, Seoung-Woo Cho, Byung-Moon |
author_sort | Jeon, Hyun-Jae |
collection | PubMed |
description | Technical advances with devices such as catheters, balloons, and stents have widened the indications for endovascular coiling for unfavorable aneurysms. The authors report two cases of coil embolization for a wide-neck bifurcated aneurysm with anterograde horizontal stenting via microcatheter looping. Two women, aged 56 and 38 years, respectively, had an undertall- and overwide-neck aneurysm with bifurcated branches at the basilar bifurcation and middle cerebral bifurcation, respectively. The delivery microcatheter was steamed so that it could be looped deliberately to the opposite vessel. The enterprise stent was first anchored to the vessel of the posterior cerebral artery on one side. The remaining portion was spanned into a looped microcatheter to the opposite branch while pushing the stent. The Neuroform Atlas stent was passed directly through the looped segment of the microcatheter at the M2 branch and spanned horizontally by unsheathing. Under horizontal stenting, complete coil embolization was achieved without immediate or delayed complications in both cases. This novel technique presents a viable option for stent-assisted coiling within an optimal anatomy. |
format | Online Article Text |
id | pubmed-6199400 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Society of Cerebrovascular Surgeons; Society of Korean Endovascular Neurosurgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-61994002018-11-05 Endovascular Coiling for a Wide-neck Bifurcated Aneurysm with Anterograde Horizontal Stenting via Microcatheter Looping: A Technical Case Report Jeon, Hyun-Jae Park, Jong-Hwa Lee, Jong-Young Jeon, Hong-Jun Park, Seoung-Woo Cho, Byung-Moon J Cerebrovasc Endovasc Neurosurg Case Report Technical advances with devices such as catheters, balloons, and stents have widened the indications for endovascular coiling for unfavorable aneurysms. The authors report two cases of coil embolization for a wide-neck bifurcated aneurysm with anterograde horizontal stenting via microcatheter looping. Two women, aged 56 and 38 years, respectively, had an undertall- and overwide-neck aneurysm with bifurcated branches at the basilar bifurcation and middle cerebral bifurcation, respectively. The delivery microcatheter was steamed so that it could be looped deliberately to the opposite vessel. The enterprise stent was first anchored to the vessel of the posterior cerebral artery on one side. The remaining portion was spanned into a looped microcatheter to the opposite branch while pushing the stent. The Neuroform Atlas stent was passed directly through the looped segment of the microcatheter at the M2 branch and spanned horizontally by unsheathing. Under horizontal stenting, complete coil embolization was achieved without immediate or delayed complications in both cases. This novel technique presents a viable option for stent-assisted coiling within an optimal anatomy. Korean Society of Cerebrovascular Surgeons; Society of Korean Endovascular Neurosurgeons 2018-09 2018-09-30 /pmc/articles/PMC6199400/ /pubmed/30397590 http://dx.doi.org/10.7461/jcen.2018.20.3.181 Text en © 2018 Journal of Cerebrovascular and Endovascular Neurosurgery http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Jeon, Hyun-Jae Park, Jong-Hwa Lee, Jong-Young Jeon, Hong-Jun Park, Seoung-Woo Cho, Byung-Moon Endovascular Coiling for a Wide-neck Bifurcated Aneurysm with Anterograde Horizontal Stenting via Microcatheter Looping: A Technical Case Report |
title | Endovascular Coiling for a Wide-neck Bifurcated Aneurysm with Anterograde Horizontal Stenting via Microcatheter Looping: A Technical Case Report |
title_full | Endovascular Coiling for a Wide-neck Bifurcated Aneurysm with Anterograde Horizontal Stenting via Microcatheter Looping: A Technical Case Report |
title_fullStr | Endovascular Coiling for a Wide-neck Bifurcated Aneurysm with Anterograde Horizontal Stenting via Microcatheter Looping: A Technical Case Report |
title_full_unstemmed | Endovascular Coiling for a Wide-neck Bifurcated Aneurysm with Anterograde Horizontal Stenting via Microcatheter Looping: A Technical Case Report |
title_short | Endovascular Coiling for a Wide-neck Bifurcated Aneurysm with Anterograde Horizontal Stenting via Microcatheter Looping: A Technical Case Report |
title_sort | endovascular coiling for a wide-neck bifurcated aneurysm with anterograde horizontal stenting via microcatheter looping: a technical case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6199400/ https://www.ncbi.nlm.nih.gov/pubmed/30397590 http://dx.doi.org/10.7461/jcen.2018.20.3.181 |
work_keys_str_mv | AT jeonhyunjae endovascularcoilingforawideneckbifurcatedaneurysmwithanterogradehorizontalstentingviamicrocatheterloopingatechnicalcasereport AT parkjonghwa endovascularcoilingforawideneckbifurcatedaneurysmwithanterogradehorizontalstentingviamicrocatheterloopingatechnicalcasereport AT leejongyoung endovascularcoilingforawideneckbifurcatedaneurysmwithanterogradehorizontalstentingviamicrocatheterloopingatechnicalcasereport AT jeonhongjun endovascularcoilingforawideneckbifurcatedaneurysmwithanterogradehorizontalstentingviamicrocatheterloopingatechnicalcasereport AT parkseoungwoo endovascularcoilingforawideneckbifurcatedaneurysmwithanterogradehorizontalstentingviamicrocatheterloopingatechnicalcasereport AT chobyungmoon endovascularcoilingforawideneckbifurcatedaneurysmwithanterogradehorizontalstentingviamicrocatheterloopingatechnicalcasereport |