Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry
The usefulness of anthropometry to define childhood malnutrition is undermined by poor measurement quality, which led to calls for new measurement approaches. We evaluated the ability of a 3D imaging system to correctly measure child stature (length or height), head circumference and arm circumferen...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6200231/ https://www.ncbi.nlm.nih.gov/pubmed/30356325 http://dx.doi.org/10.1371/journal.pone.0205320 |
_version_ | 1783365295399763968 |
---|---|
author | Conkle, Joel Suchdev, Parminder S. Alexander, Eugene Flores-Ayala, Rafael Ramakrishnan, Usha Martorell, Reynaldo |
author_facet | Conkle, Joel Suchdev, Parminder S. Alexander, Eugene Flores-Ayala, Rafael Ramakrishnan, Usha Martorell, Reynaldo |
author_sort | Conkle, Joel |
collection | PubMed |
description | The usefulness of anthropometry to define childhood malnutrition is undermined by poor measurement quality, which led to calls for new measurement approaches. We evaluated the ability of a 3D imaging system to correctly measure child stature (length or height), head circumference and arm circumference. In 2016–7 we recruited and measured children at 20 facilities in and around metro Atlanta, Georgia, USA; including at daycare, higher education, religious, and medical facilities. We selected recruitment sites to reflect a generally representative population of Atlanta and to oversample newborns and children under two years of age. Using convenience sampling, a total of 474 children 0–5 years of age who were apparently healthy and who were present at the time of data collection were included in the analysis. Two anthropometrists each took repeated manual measures and repeated 3D scans of each child. We evaluated the reliability and accuracy of 3D scan-derived measurements against manual measurements. The mean child age was 26 months, and 48% of children were female. Based on reported race and ethnicity, the sample was 42% Black, 28% White, 8% Asian, 21% multiple races, other or race not reported; and 16% Hispanic. Measurement reliability of repeated 3D scans was within 1 mm of manual measurement reliability for stature, head circumference and arm circumference. We found systematic bias when analyzing accuracy—on average 3D imaging overestimated stature and head circumference by 6 mm and 3 mm respectively, and underestimated arm circumference by 2 mm. The 3D imaging system used in this study is reliable, low-cost, portable, and can handle movement; making it ideal for use in routine nutritional assessment. However, additional research, particularly on accuracy, and further development of the scanning and processing software is needed before making policy and clinical practice recommendations on the routine use of 3D imaging for child anthropometry. |
format | Online Article Text |
id | pubmed-6200231 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-62002312018-11-19 Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry Conkle, Joel Suchdev, Parminder S. Alexander, Eugene Flores-Ayala, Rafael Ramakrishnan, Usha Martorell, Reynaldo PLoS One Research Article The usefulness of anthropometry to define childhood malnutrition is undermined by poor measurement quality, which led to calls for new measurement approaches. We evaluated the ability of a 3D imaging system to correctly measure child stature (length or height), head circumference and arm circumference. In 2016–7 we recruited and measured children at 20 facilities in and around metro Atlanta, Georgia, USA; including at daycare, higher education, religious, and medical facilities. We selected recruitment sites to reflect a generally representative population of Atlanta and to oversample newborns and children under two years of age. Using convenience sampling, a total of 474 children 0–5 years of age who were apparently healthy and who were present at the time of data collection were included in the analysis. Two anthropometrists each took repeated manual measures and repeated 3D scans of each child. We evaluated the reliability and accuracy of 3D scan-derived measurements against manual measurements. The mean child age was 26 months, and 48% of children were female. Based on reported race and ethnicity, the sample was 42% Black, 28% White, 8% Asian, 21% multiple races, other or race not reported; and 16% Hispanic. Measurement reliability of repeated 3D scans was within 1 mm of manual measurement reliability for stature, head circumference and arm circumference. We found systematic bias when analyzing accuracy—on average 3D imaging overestimated stature and head circumference by 6 mm and 3 mm respectively, and underestimated arm circumference by 2 mm. The 3D imaging system used in this study is reliable, low-cost, portable, and can handle movement; making it ideal for use in routine nutritional assessment. However, additional research, particularly on accuracy, and further development of the scanning and processing software is needed before making policy and clinical practice recommendations on the routine use of 3D imaging for child anthropometry. Public Library of Science 2018-10-24 /pmc/articles/PMC6200231/ /pubmed/30356325 http://dx.doi.org/10.1371/journal.pone.0205320 Text en https://creativecommons.org/publicdomain/zero/1.0/ This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 (https://creativecommons.org/publicdomain/zero/1.0/) public domain dedication. |
spellingShingle | Research Article Conkle, Joel Suchdev, Parminder S. Alexander, Eugene Flores-Ayala, Rafael Ramakrishnan, Usha Martorell, Reynaldo Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry |
title | Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry |
title_full | Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry |
title_fullStr | Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry |
title_full_unstemmed | Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry |
title_short | Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry |
title_sort | accuracy and reliability of a low-cost, handheld 3d imaging system for child anthropometry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6200231/ https://www.ncbi.nlm.nih.gov/pubmed/30356325 http://dx.doi.org/10.1371/journal.pone.0205320 |
work_keys_str_mv | AT conklejoel accuracyandreliabilityofalowcosthandheld3dimagingsystemforchildanthropometry AT suchdevparminders accuracyandreliabilityofalowcosthandheld3dimagingsystemforchildanthropometry AT alexandereugene accuracyandreliabilityofalowcosthandheld3dimagingsystemforchildanthropometry AT floresayalarafael accuracyandreliabilityofalowcosthandheld3dimagingsystemforchildanthropometry AT ramakrishnanusha accuracyandreliabilityofalowcosthandheld3dimagingsystemforchildanthropometry AT martorellreynaldo accuracyandreliabilityofalowcosthandheld3dimagingsystemforchildanthropometry |