Cargando…

Evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking

PURPOSE: The aim of this study is to quantify and describe the feasibility, clinical outcomes, and patient-reported outcomes of reduced planning target volume (PTV) margins for prostate cancer treatment using real-time, continuous, intrafraction monitoring with implanted radiation frequency transpon...

Descripción completa

Detalles Bibliográficos
Autores principales: Chaurasia, Avinash R., Sun, Kelly J., Premo, Christopher, Brand, Timothy, Tinnel, Brent, Barczak, Stacie, Halligan, John, Brown, Michael, Macdonald, Dusten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6200876/
https://www.ncbi.nlm.nih.gov/pubmed/30370364
http://dx.doi.org/10.1016/j.adro.2018.06.004
_version_ 1783365414336593920
author Chaurasia, Avinash R.
Sun, Kelly J.
Premo, Christopher
Brand, Timothy
Tinnel, Brent
Barczak, Stacie
Halligan, John
Brown, Michael
Macdonald, Dusten
author_facet Chaurasia, Avinash R.
Sun, Kelly J.
Premo, Christopher
Brand, Timothy
Tinnel, Brent
Barczak, Stacie
Halligan, John
Brown, Michael
Macdonald, Dusten
author_sort Chaurasia, Avinash R.
collection PubMed
description PURPOSE: The aim of this study is to quantify and describe the feasibility, clinical outcomes, and patient-reported outcomes of reduced planning target volume (PTV) margins for prostate cancer treatment using real-time, continuous, intrafraction monitoring with implanted radiation frequency transponder beacons. METHODS AND MATERIALS: For this prospective, nonrandomized trial, the Calypso localization system was used for intrafraction target localization in 31 patients with a PTV margin reduced to 2 mm in all directions. A total of 1333 fractions were analyzed with respect to movement of the prostate, pauses and interruptions, and dosimetric data. Pre- and posttreatment quality-of-life scores were tracked at baseline, during treatment, and up to 24 months after treatment. RESULTS: The mean time of daily treatment was 10 minutes, with 96.1% of all treatments falling within a 20-minute treatment window standard. On average, beacon motion exceeded 3 mm during active treatment only 1.76% of the time. The average length of treatment interruption was 34.2 seconds, with an average of 1 interruption every 3.39 fractions. The displacement or excursion of the prostate was the greatest in the superior or inferior dimension (0.11 mm and 0.09 mm, respectively) and anterior or posterior dimension (0.07 mm and 0.13 mm, respectively), followed by the left or right dimension (0.05 mm and 0.06 mm, respectively). At 6 months, patients demonstrated a smaller change in Expanded Prostate Cancer Index Composite scores than the ProtecT comparator group (decreased short-term morbidity). However, in the Bowel and Urinary domains at 12 and 24 months, there was no significant difference. CONCLUSIONS: Our data confirm and support that the use of Calypso tracking with intensity modulated radiation therapy reliably provides minimal disruption to daily treatments and overall time of treatment, with the PTV only moving outside of a 3-mm margin < 2% of the time. The use of a 3-mm PTV margin provides adequate dosimetric coverage while minimizing genitourinary and gastrointestinal toxicity.
format Online
Article
Text
id pubmed-6200876
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-62008762018-10-26 Evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking Chaurasia, Avinash R. Sun, Kelly J. Premo, Christopher Brand, Timothy Tinnel, Brent Barczak, Stacie Halligan, John Brown, Michael Macdonald, Dusten Adv Radiat Oncol Genitourinary Cancer PURPOSE: The aim of this study is to quantify and describe the feasibility, clinical outcomes, and patient-reported outcomes of reduced planning target volume (PTV) margins for prostate cancer treatment using real-time, continuous, intrafraction monitoring with implanted radiation frequency transponder beacons. METHODS AND MATERIALS: For this prospective, nonrandomized trial, the Calypso localization system was used for intrafraction target localization in 31 patients with a PTV margin reduced to 2 mm in all directions. A total of 1333 fractions were analyzed with respect to movement of the prostate, pauses and interruptions, and dosimetric data. Pre- and posttreatment quality-of-life scores were tracked at baseline, during treatment, and up to 24 months after treatment. RESULTS: The mean time of daily treatment was 10 minutes, with 96.1% of all treatments falling within a 20-minute treatment window standard. On average, beacon motion exceeded 3 mm during active treatment only 1.76% of the time. The average length of treatment interruption was 34.2 seconds, with an average of 1 interruption every 3.39 fractions. The displacement or excursion of the prostate was the greatest in the superior or inferior dimension (0.11 mm and 0.09 mm, respectively) and anterior or posterior dimension (0.07 mm and 0.13 mm, respectively), followed by the left or right dimension (0.05 mm and 0.06 mm, respectively). At 6 months, patients demonstrated a smaller change in Expanded Prostate Cancer Index Composite scores than the ProtecT comparator group (decreased short-term morbidity). However, in the Bowel and Urinary domains at 12 and 24 months, there was no significant difference. CONCLUSIONS: Our data confirm and support that the use of Calypso tracking with intensity modulated radiation therapy reliably provides minimal disruption to daily treatments and overall time of treatment, with the PTV only moving outside of a 3-mm margin < 2% of the time. The use of a 3-mm PTV margin provides adequate dosimetric coverage while minimizing genitourinary and gastrointestinal toxicity. Elsevier 2018-07-11 /pmc/articles/PMC6200876/ /pubmed/30370364 http://dx.doi.org/10.1016/j.adro.2018.06.004 Text en © 2018 The Authors on behalf of the American Society for Radiation Oncology http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Genitourinary Cancer
Chaurasia, Avinash R.
Sun, Kelly J.
Premo, Christopher
Brand, Timothy
Tinnel, Brent
Barczak, Stacie
Halligan, John
Brown, Michael
Macdonald, Dusten
Evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking
title Evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking
title_full Evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking
title_fullStr Evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking
title_full_unstemmed Evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking
title_short Evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking
title_sort evaluating the potential benefit of reduced planning target volume margins for low and intermediate risk patients with prostate cancer using real-time electromagnetic tracking
topic Genitourinary Cancer
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6200876/
https://www.ncbi.nlm.nih.gov/pubmed/30370364
http://dx.doi.org/10.1016/j.adro.2018.06.004
work_keys_str_mv AT chaurasiaavinashr evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking
AT sunkellyj evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking
AT premochristopher evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking
AT brandtimothy evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking
AT tinnelbrent evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking
AT barczakstacie evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking
AT halliganjohn evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking
AT brownmichael evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking
AT macdonalddusten evaluatingthepotentialbenefitofreducedplanningtargetvolumemarginsforlowandintermediateriskpatientswithprostatecancerusingrealtimeelectromagnetictracking