Cargando…

Variations of MRI-assessed peristaltic motions during radiation therapy

PURPOSE: Understanding complex abdominal organ motion is essential for motion management in radiation therapy (RT) of abdominal tumors. This study investigates abdominal motion induced by respiration and peristalsis, during various time durations relevant to RT, using various CT and MRI techniques a...

Descripción completa

Detalles Bibliográficos
Autores principales: Mostafaei, Farshad, Tai, An, Omari, Eenas, Song, Yingqiu, Christian, James, Paulson, Eric, Hall, William, Erickson, Beth, Li, X. Allen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6201905/
https://www.ncbi.nlm.nih.gov/pubmed/30359413
http://dx.doi.org/10.1371/journal.pone.0205917
_version_ 1783365595869216768
author Mostafaei, Farshad
Tai, An
Omari, Eenas
Song, Yingqiu
Christian, James
Paulson, Eric
Hall, William
Erickson, Beth
Li, X. Allen
author_facet Mostafaei, Farshad
Tai, An
Omari, Eenas
Song, Yingqiu
Christian, James
Paulson, Eric
Hall, William
Erickson, Beth
Li, X. Allen
author_sort Mostafaei, Farshad
collection PubMed
description PURPOSE: Understanding complex abdominal organ motion is essential for motion management in radiation therapy (RT) of abdominal tumors. This study investigates abdominal motion induced by respiration and peristalsis, during various time durations relevant to RT, using various CT and MRI techniques acquired under free breathing (FB) and breath hold (BH). METHODS: A series of CT and MRI images acquired with various techniques under free breathing and/or breath hold from 37 randomly-selected pancreatic or liver cancer patients were analyzed to assess the motion in various time frames. These data include FB 4DCT from 15 patients (for motion in time duration of 5 sec), FB 2D cine-MRI from 4 patients (time duration of 1.7 min, 1 second acquisition time per slice), FB cine-MRI acquired using MR-Linac from 6 patients in various fractions (acquisition time is less than 0.6 seconds per slice), FB 4DMRI from 2 patients (time duration of 2 min), respiration-gated T(2) with gating at the end expiration (time duration of 3–5 min), and BH T(1) with multiphase dynamic contrast in acquisition times of 17 seconds for each of five phases (pre-contrast, arterial, venous, portal venous and delayed post-contrast) from 10 patients. Motions of various organs including gallbladder (GB) and liver were measured based on these MRI data. The GB motion includes both respiration and peristalsis, while liver motion is primarily respiration. By subtracting liver motion (respiration) from GB motion (respiration and peristalsis), the peristaltic motion, along with small residual motion, was obtained. RESULTS: From cine-MRI, the residual motion beyond the respiratory motion was found to be up to 0.6 cm in superior-inferior (SI) and 0.55 cm in anterior-posterior (AP) directions. From 2D cine-MRI acquired by the MR-Linac, different peristaltic motions were found from different fractions for each patient. The peristaltic motion was found to vary between 0.3–1 cm. From BH T(1) phase images, the average motions that were primarily due to peristalsis movements were found to be 1.2 cm in SI, 0.7 cm in AP, and 0.9 cm in left-right (LR) directions. The average motions assessed from 4DCT were 1.0 cm in SI and 0.3 cm in AP directions, which were generally smaller than the motions assessed from cine-MRI, i.e., 1.8 cm in SI and 0.6 cm in AP directions, for the same patients. However, average motions from 4DMRI, which are coming from respiratory were measured to be 1.5, 0.5, and 0.4 cm in SI, AP, and LR directions, respectively. CONCLUSION: The abdominal motion due to peristalsis can be similar in magnitude to respiratory motion as assessed. These motions can be irregular and persistent throughout the imaging and RT delivery procedures, and should be considered together with respiratory motion during RT for abdominal tumors.
format Online
Article
Text
id pubmed-6201905
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-62019052018-11-19 Variations of MRI-assessed peristaltic motions during radiation therapy Mostafaei, Farshad Tai, An Omari, Eenas Song, Yingqiu Christian, James Paulson, Eric Hall, William Erickson, Beth Li, X. Allen PLoS One Research Article PURPOSE: Understanding complex abdominal organ motion is essential for motion management in radiation therapy (RT) of abdominal tumors. This study investigates abdominal motion induced by respiration and peristalsis, during various time durations relevant to RT, using various CT and MRI techniques acquired under free breathing (FB) and breath hold (BH). METHODS: A series of CT and MRI images acquired with various techniques under free breathing and/or breath hold from 37 randomly-selected pancreatic or liver cancer patients were analyzed to assess the motion in various time frames. These data include FB 4DCT from 15 patients (for motion in time duration of 5 sec), FB 2D cine-MRI from 4 patients (time duration of 1.7 min, 1 second acquisition time per slice), FB cine-MRI acquired using MR-Linac from 6 patients in various fractions (acquisition time is less than 0.6 seconds per slice), FB 4DMRI from 2 patients (time duration of 2 min), respiration-gated T(2) with gating at the end expiration (time duration of 3–5 min), and BH T(1) with multiphase dynamic contrast in acquisition times of 17 seconds for each of five phases (pre-contrast, arterial, venous, portal venous and delayed post-contrast) from 10 patients. Motions of various organs including gallbladder (GB) and liver were measured based on these MRI data. The GB motion includes both respiration and peristalsis, while liver motion is primarily respiration. By subtracting liver motion (respiration) from GB motion (respiration and peristalsis), the peristaltic motion, along with small residual motion, was obtained. RESULTS: From cine-MRI, the residual motion beyond the respiratory motion was found to be up to 0.6 cm in superior-inferior (SI) and 0.55 cm in anterior-posterior (AP) directions. From 2D cine-MRI acquired by the MR-Linac, different peristaltic motions were found from different fractions for each patient. The peristaltic motion was found to vary between 0.3–1 cm. From BH T(1) phase images, the average motions that were primarily due to peristalsis movements were found to be 1.2 cm in SI, 0.7 cm in AP, and 0.9 cm in left-right (LR) directions. The average motions assessed from 4DCT were 1.0 cm in SI and 0.3 cm in AP directions, which were generally smaller than the motions assessed from cine-MRI, i.e., 1.8 cm in SI and 0.6 cm in AP directions, for the same patients. However, average motions from 4DMRI, which are coming from respiratory were measured to be 1.5, 0.5, and 0.4 cm in SI, AP, and LR directions, respectively. CONCLUSION: The abdominal motion due to peristalsis can be similar in magnitude to respiratory motion as assessed. These motions can be irregular and persistent throughout the imaging and RT delivery procedures, and should be considered together with respiratory motion during RT for abdominal tumors. Public Library of Science 2018-10-25 /pmc/articles/PMC6201905/ /pubmed/30359413 http://dx.doi.org/10.1371/journal.pone.0205917 Text en © 2018 Mostafaei et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Mostafaei, Farshad
Tai, An
Omari, Eenas
Song, Yingqiu
Christian, James
Paulson, Eric
Hall, William
Erickson, Beth
Li, X. Allen
Variations of MRI-assessed peristaltic motions during radiation therapy
title Variations of MRI-assessed peristaltic motions during radiation therapy
title_full Variations of MRI-assessed peristaltic motions during radiation therapy
title_fullStr Variations of MRI-assessed peristaltic motions during radiation therapy
title_full_unstemmed Variations of MRI-assessed peristaltic motions during radiation therapy
title_short Variations of MRI-assessed peristaltic motions during radiation therapy
title_sort variations of mri-assessed peristaltic motions during radiation therapy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6201905/
https://www.ncbi.nlm.nih.gov/pubmed/30359413
http://dx.doi.org/10.1371/journal.pone.0205917
work_keys_str_mv AT mostafaeifarshad variationsofmriassessedperistalticmotionsduringradiationtherapy
AT taian variationsofmriassessedperistalticmotionsduringradiationtherapy
AT omarieenas variationsofmriassessedperistalticmotionsduringradiationtherapy
AT songyingqiu variationsofmriassessedperistalticmotionsduringradiationtherapy
AT christianjames variationsofmriassessedperistalticmotionsduringradiationtherapy
AT paulsoneric variationsofmriassessedperistalticmotionsduringradiationtherapy
AT hallwilliam variationsofmriassessedperistalticmotionsduringradiationtherapy
AT ericksonbeth variationsofmriassessedperistalticmotionsduringradiationtherapy
AT lixallen variationsofmriassessedperistalticmotionsduringradiationtherapy