Cargando…
Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation
OBJECTIVE: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. MATERIALS AND METHODS: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6201976/ https://www.ncbi.nlm.nih.gov/pubmed/30386139 http://dx.doi.org/10.3348/kjr.2018.19.6.1077 |
_version_ | 1783365613081591808 |
---|---|
author | Kim, Yeon Soo Kim, Se Hyung Ryu, Hwa Sung Han, Joon Koo |
author_facet | Kim, Yeon Soo Kim, Se Hyung Ryu, Hwa Sung Han, Joon Koo |
author_sort | Kim, Yeon Soo |
collection | PubMed |
description | OBJECTIVE: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. MATERIALS AND METHODS: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. RESULTS: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. CONCLUSION: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD. |
format | Online Article Text |
id | pubmed-6201976 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-62019762018-11-01 Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation Kim, Yeon Soo Kim, Se Hyung Ryu, Hwa Sung Han, Joon Koo Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. MATERIALS AND METHODS: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. RESULTS: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. CONCLUSION: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD. The Korean Society of Radiology 2018 2018-10-18 /pmc/articles/PMC6201976/ /pubmed/30386139 http://dx.doi.org/10.3348/kjr.2018.19.6.1077 Text en Copyright © 2018 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Gastrointestinal Imaging Kim, Yeon Soo Kim, Se Hyung Ryu, Hwa Sung Han, Joon Koo Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation |
title | Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation |
title_full | Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation |
title_fullStr | Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation |
title_full_unstemmed | Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation |
title_short | Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation |
title_sort | iodine quantification on spectral detector-based dual-energy ct enterography: correlation with crohn's disease activity index and external validation |
topic | Gastrointestinal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6201976/ https://www.ncbi.nlm.nih.gov/pubmed/30386139 http://dx.doi.org/10.3348/kjr.2018.19.6.1077 |
work_keys_str_mv | AT kimyeonsoo iodinequantificationonspectraldetectorbaseddualenergyctenterographycorrelationwithcrohnsdiseaseactivityindexandexternalvalidation AT kimsehyung iodinequantificationonspectraldetectorbaseddualenergyctenterographycorrelationwithcrohnsdiseaseactivityindexandexternalvalidation AT ryuhwasung iodinequantificationonspectraldetectorbaseddualenergyctenterographycorrelationwithcrohnsdiseaseactivityindexandexternalvalidation AT hanjoonkoo iodinequantificationonspectraldetectorbaseddualenergyctenterographycorrelationwithcrohnsdiseaseactivityindexandexternalvalidation |