Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease

OBJECTIVE: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: We prospectively...

Descripción completa

Detalles Bibliográficos
Autores principales: Min, Jee Young, Ko, Sung Min, Song, In Young, Yi, Jung Geun, Hwang, Hweung Kon, Shin, Je Kyoun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6201977/
https://www.ncbi.nlm.nih.gov/pubmed/30386133
http://dx.doi.org/10.3348/kjr.2018.19.6.1007
_version_ 1783365613321715712
author Min, Jee Young
Ko, Sung Min
Song, In Young
Yi, Jung Geun
Hwang, Hweung Kon
Shin, Je Kyoun
author_facet Min, Jee Young
Ko, Sung Min
Song, In Young
Yi, Jung Geun
Hwang, Hweung Kon
Shin, Je Kyoun
author_sort Min, Jee Young
collection PubMed
description OBJECTIVE: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: We prospectively enrolled 281 patients (age 62.4 ± 8.3 years, 193 men) with suspected or known CAD who had undergone 1.5T or 3T CMR and ICA. Two independent radiologists interpreted perfusion defects. With ICA as the reference standard, the diagnostic performance of 1.5T and 3T CMR for identifying significant CAD (≥ 50% diameter reduction of the left main and ≥ 70% diameter reduction of other epicardial arteries) was determined. RESULTS: No differences were observed in baseline characteristics or prevalence of CAD and old myocardial infarction (MI) using 1.5T (n = 135) or 3T (n = 146) systems. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) for detecting significant CAD were similar between the 1.5T (84%, 64%, 74%, 76%, and 0.75 per patient and 68%, 83%, 66%, 84%, and 0.76 per vessel) and 3T (80%, 71%, 71%, 80%, and 0.76 per patient and 75%, 86%, 64%, 91%, and 0.81 per vessel) systems. In patients with multi-vessel CAD without old MI, the sensitivity, specificity, and AUC with 3T were greater than those with 1.5T on a per-vessel basis (71% vs. 36%, 92% vs. 69%, and 0.82 vs. 0.53, respectively). CONCLUSION: 3T CMR has similar diagnostic performance to 1.5T CMR in detecting significant CAD, except for higher diagnostic performance in patients with multi-vessel CAD without old MI.
format Online
Article
Text
id pubmed-6201977
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-62019772018-11-01 Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease Min, Jee Young Ko, Sung Min Song, In Young Yi, Jung Geun Hwang, Hweung Kon Shin, Je Kyoun Korean J Radiol Cardiovascular Imaging OBJECTIVE: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: We prospectively enrolled 281 patients (age 62.4 ± 8.3 years, 193 men) with suspected or known CAD who had undergone 1.5T or 3T CMR and ICA. Two independent radiologists interpreted perfusion defects. With ICA as the reference standard, the diagnostic performance of 1.5T and 3T CMR for identifying significant CAD (≥ 50% diameter reduction of the left main and ≥ 70% diameter reduction of other epicardial arteries) was determined. RESULTS: No differences were observed in baseline characteristics or prevalence of CAD and old myocardial infarction (MI) using 1.5T (n = 135) or 3T (n = 146) systems. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) for detecting significant CAD were similar between the 1.5T (84%, 64%, 74%, 76%, and 0.75 per patient and 68%, 83%, 66%, 84%, and 0.76 per vessel) and 3T (80%, 71%, 71%, 80%, and 0.76 per patient and 75%, 86%, 64%, 91%, and 0.81 per vessel) systems. In patients with multi-vessel CAD without old MI, the sensitivity, specificity, and AUC with 3T were greater than those with 1.5T on a per-vessel basis (71% vs. 36%, 92% vs. 69%, and 0.82 vs. 0.53, respectively). CONCLUSION: 3T CMR has similar diagnostic performance to 1.5T CMR in detecting significant CAD, except for higher diagnostic performance in patients with multi-vessel CAD without old MI. The Korean Society of Radiology 2018 2018-10-18 /pmc/articles/PMC6201977/ /pubmed/30386133 http://dx.doi.org/10.3348/kjr.2018.19.6.1007 Text en Copyright © 2018 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Min, Jee Young
Ko, Sung Min
Song, In Young
Yi, Jung Geun
Hwang, Hweung Kon
Shin, Je Kyoun
Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease
title Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease
title_full Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease
title_fullStr Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease
title_full_unstemmed Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease
title_short Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease
title_sort comparison of the diagnostic accuracies of 1.5t and 3t stress myocardial perfusion cardiovascular magnetic resonance for detecting significant coronary artery disease
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6201977/
https://www.ncbi.nlm.nih.gov/pubmed/30386133
http://dx.doi.org/10.3348/kjr.2018.19.6.1007
work_keys_str_mv AT minjeeyoung comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease
AT kosungmin comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease
AT songinyoung comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease
AT yijunggeun comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease
AT hwanghweungkon comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease
AT shinjekyoun comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease