Cargando…
Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease
OBJECTIVE: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: We prospectively...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6201977/ https://www.ncbi.nlm.nih.gov/pubmed/30386133 http://dx.doi.org/10.3348/kjr.2018.19.6.1007 |
_version_ | 1783365613321715712 |
---|---|
author | Min, Jee Young Ko, Sung Min Song, In Young Yi, Jung Geun Hwang, Hweung Kon Shin, Je Kyoun |
author_facet | Min, Jee Young Ko, Sung Min Song, In Young Yi, Jung Geun Hwang, Hweung Kon Shin, Je Kyoun |
author_sort | Min, Jee Young |
collection | PubMed |
description | OBJECTIVE: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: We prospectively enrolled 281 patients (age 62.4 ± 8.3 years, 193 men) with suspected or known CAD who had undergone 1.5T or 3T CMR and ICA. Two independent radiologists interpreted perfusion defects. With ICA as the reference standard, the diagnostic performance of 1.5T and 3T CMR for identifying significant CAD (≥ 50% diameter reduction of the left main and ≥ 70% diameter reduction of other epicardial arteries) was determined. RESULTS: No differences were observed in baseline characteristics or prevalence of CAD and old myocardial infarction (MI) using 1.5T (n = 135) or 3T (n = 146) systems. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) for detecting significant CAD were similar between the 1.5T (84%, 64%, 74%, 76%, and 0.75 per patient and 68%, 83%, 66%, 84%, and 0.76 per vessel) and 3T (80%, 71%, 71%, 80%, and 0.76 per patient and 75%, 86%, 64%, 91%, and 0.81 per vessel) systems. In patients with multi-vessel CAD without old MI, the sensitivity, specificity, and AUC with 3T were greater than those with 1.5T on a per-vessel basis (71% vs. 36%, 92% vs. 69%, and 0.82 vs. 0.53, respectively). CONCLUSION: 3T CMR has similar diagnostic performance to 1.5T CMR in detecting significant CAD, except for higher diagnostic performance in patients with multi-vessel CAD without old MI. |
format | Online Article Text |
id | pubmed-6201977 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-62019772018-11-01 Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease Min, Jee Young Ko, Sung Min Song, In Young Yi, Jung Geun Hwang, Hweung Kon Shin, Je Kyoun Korean J Radiol Cardiovascular Imaging OBJECTIVE: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: We prospectively enrolled 281 patients (age 62.4 ± 8.3 years, 193 men) with suspected or known CAD who had undergone 1.5T or 3T CMR and ICA. Two independent radiologists interpreted perfusion defects. With ICA as the reference standard, the diagnostic performance of 1.5T and 3T CMR for identifying significant CAD (≥ 50% diameter reduction of the left main and ≥ 70% diameter reduction of other epicardial arteries) was determined. RESULTS: No differences were observed in baseline characteristics or prevalence of CAD and old myocardial infarction (MI) using 1.5T (n = 135) or 3T (n = 146) systems. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) for detecting significant CAD were similar between the 1.5T (84%, 64%, 74%, 76%, and 0.75 per patient and 68%, 83%, 66%, 84%, and 0.76 per vessel) and 3T (80%, 71%, 71%, 80%, and 0.76 per patient and 75%, 86%, 64%, 91%, and 0.81 per vessel) systems. In patients with multi-vessel CAD without old MI, the sensitivity, specificity, and AUC with 3T were greater than those with 1.5T on a per-vessel basis (71% vs. 36%, 92% vs. 69%, and 0.82 vs. 0.53, respectively). CONCLUSION: 3T CMR has similar diagnostic performance to 1.5T CMR in detecting significant CAD, except for higher diagnostic performance in patients with multi-vessel CAD without old MI. The Korean Society of Radiology 2018 2018-10-18 /pmc/articles/PMC6201977/ /pubmed/30386133 http://dx.doi.org/10.3348/kjr.2018.19.6.1007 Text en Copyright © 2018 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Cardiovascular Imaging Min, Jee Young Ko, Sung Min Song, In Young Yi, Jung Geun Hwang, Hweung Kon Shin, Je Kyoun Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease |
title | Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease |
title_full | Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease |
title_fullStr | Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease |
title_full_unstemmed | Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease |
title_short | Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease |
title_sort | comparison of the diagnostic accuracies of 1.5t and 3t stress myocardial perfusion cardiovascular magnetic resonance for detecting significant coronary artery disease |
topic | Cardiovascular Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6201977/ https://www.ncbi.nlm.nih.gov/pubmed/30386133 http://dx.doi.org/10.3348/kjr.2018.19.6.1007 |
work_keys_str_mv | AT minjeeyoung comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease AT kosungmin comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease AT songinyoung comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease AT yijunggeun comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease AT hwanghweungkon comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease AT shinjekyoun comparisonofthediagnosticaccuraciesof15tand3tstressmyocardialperfusioncardiovascularmagneticresonancefordetectingsignificantcoronaryarterydisease |