Cargando…

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

PURPOSE: Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prosthe...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Kyu-Hyung, Son, KeunBaDa, Lee, Du-Hyeong, Lee, Kyu-Bok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202427/
https://www.ncbi.nlm.nih.gov/pubmed/30370030
http://dx.doi.org/10.4047/jap.2018.10.5.381
_version_ 1783365678639611904
author Choi, Kyu-Hyung
Son, KeunBaDa
Lee, Du-Hyeong
Lee, Kyu-Bok
author_facet Choi, Kyu-Hyung
Son, KeunBaDa
Lee, Du-Hyeong
Lee, Kyu-Bok
author_sort Choi, Kyu-Hyung
collection PubMed
description PURPOSE: Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS: We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles (8°, 10°, and 12°), a sloped shoulder margin (0.6 mm depth), a rectangular shape (6 mm × 6.5 mm) with rounded edges, and a rectangular ledge (2 mm × 1 mm) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque (N·cm) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (α=.05). RESULTS: Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION: Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.
format Online
Article
Text
id pubmed-6202427
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-62024272018-10-26 Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot Choi, Kyu-Hyung Son, KeunBaDa Lee, Du-Hyeong Lee, Kyu-Bok J Adv Prosthodont Original Article PURPOSE: Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS: We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles (8°, 10°, and 12°), a sloped shoulder margin (0.6 mm depth), a rectangular shape (6 mm × 6.5 mm) with rounded edges, and a rectangular ledge (2 mm × 1 mm) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque (N·cm) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (α=.05). RESULTS: Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION: Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together. The Korean Academy of Prosthodontics 2018-10 2018-10-22 /pmc/articles/PMC6202427/ /pubmed/30370030 http://dx.doi.org/10.4047/jap.2018.10.5.381 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Choi, Kyu-Hyung
Son, KeunBaDa
Lee, Du-Hyeong
Lee, Kyu-Bok
Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
title Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
title_full Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
title_fullStr Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
title_full_unstemmed Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
title_short Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
title_sort influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202427/
https://www.ncbi.nlm.nih.gov/pubmed/30370030
http://dx.doi.org/10.4047/jap.2018.10.5.381
work_keys_str_mv AT choikyuhyung influenceofabutmentheightandconvergenceangleontheretrievabilityofcementretainedimplantprostheseswithalingualslot
AT sonkeunbada influenceofabutmentheightandconvergenceangleontheretrievabilityofcementretainedimplantprostheseswithalingualslot
AT leeduhyeong influenceofabutmentheightandconvergenceangleontheretrievabilityofcementretainedimplantprostheseswithalingualslot
AT leekyubok influenceofabutmentheightandconvergenceangleontheretrievabilityofcementretainedimplantprostheseswithalingualslot