Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
PURPOSE: Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prosthe...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202427/ https://www.ncbi.nlm.nih.gov/pubmed/30370030 http://dx.doi.org/10.4047/jap.2018.10.5.381 |
_version_ | 1783365678639611904 |
---|---|
author | Choi, Kyu-Hyung Son, KeunBaDa Lee, Du-Hyeong Lee, Kyu-Bok |
author_facet | Choi, Kyu-Hyung Son, KeunBaDa Lee, Du-Hyeong Lee, Kyu-Bok |
author_sort | Choi, Kyu-Hyung |
collection | PubMed |
description | PURPOSE: Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS: We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles (8°, 10°, and 12°), a sloped shoulder margin (0.6 mm depth), a rectangular shape (6 mm × 6.5 mm) with rounded edges, and a rectangular ledge (2 mm × 1 mm) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque (N·cm) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (α=.05). RESULTS: Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION: Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together. |
format | Online Article Text |
id | pubmed-6202427 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-62024272018-10-26 Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot Choi, Kyu-Hyung Son, KeunBaDa Lee, Du-Hyeong Lee, Kyu-Bok J Adv Prosthodont Original Article PURPOSE: Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS: We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles (8°, 10°, and 12°), a sloped shoulder margin (0.6 mm depth), a rectangular shape (6 mm × 6.5 mm) with rounded edges, and a rectangular ledge (2 mm × 1 mm) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque (N·cm) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (α=.05). RESULTS: Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION: Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together. The Korean Academy of Prosthodontics 2018-10 2018-10-22 /pmc/articles/PMC6202427/ /pubmed/30370030 http://dx.doi.org/10.4047/jap.2018.10.5.381 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Choi, Kyu-Hyung Son, KeunBaDa Lee, Du-Hyeong Lee, Kyu-Bok Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot |
title | Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot |
title_full | Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot |
title_fullStr | Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot |
title_full_unstemmed | Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot |
title_short | Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot |
title_sort | influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202427/ https://www.ncbi.nlm.nih.gov/pubmed/30370030 http://dx.doi.org/10.4047/jap.2018.10.5.381 |
work_keys_str_mv | AT choikyuhyung influenceofabutmentheightandconvergenceangleontheretrievabilityofcementretainedimplantprostheseswithalingualslot AT sonkeunbada influenceofabutmentheightandconvergenceangleontheretrievabilityofcementretainedimplantprostheseswithalingualslot AT leeduhyeong influenceofabutmentheightandconvergenceangleontheretrievabilityofcementretainedimplantprostheseswithalingualslot AT leekyubok influenceofabutmentheightandconvergenceangleontheretrievabilityofcementretainedimplantprostheseswithalingualslot |