Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study
PURPOSE: To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS: Twenty models of missing mandibular le...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202430/ https://www.ncbi.nlm.nih.gov/pubmed/30370031 http://dx.doi.org/10.4047/jap.2018.10.5.388 |
_version_ | 1783365679368372224 |
---|---|
author | Kim, Sung-Jun Son, KeunBaDa Lee, Kyu-Bok |
author_facet | Kim, Sung-Jun Son, KeunBaDa Lee, Kyu-Bok |
author_sort | Kim, Sung-Jun |
collection | PubMed |
description | PURPOSE: To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS: Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at 10 N·cm, simulating hand tightening, and then at the manufacturers' recommended torque (30 N·cm) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS: Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION: Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening. |
format | Online Article Text |
id | pubmed-6202430 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-62024302018-10-26 Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study Kim, Sung-Jun Son, KeunBaDa Lee, Kyu-Bok J Adv Prosthodont Original Article PURPOSE: To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS: Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at 10 N·cm, simulating hand tightening, and then at the manufacturers' recommended torque (30 N·cm) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS: Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION: Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening. The Korean Academy of Prosthodontics 2018-10 2018-10-22 /pmc/articles/PMC6202430/ /pubmed/30370031 http://dx.doi.org/10.4047/jap.2018.10.5.388 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Sung-Jun Son, KeunBaDa Lee, Kyu-Bok Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study |
title | Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study |
title_full | Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study |
title_fullStr | Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study |
title_full_unstemmed | Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study |
title_short | Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study |
title_sort | digital evaluation of axial displacement by implant-abutment connection type: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202430/ https://www.ncbi.nlm.nih.gov/pubmed/30370031 http://dx.doi.org/10.4047/jap.2018.10.5.388 |
work_keys_str_mv | AT kimsungjun digitalevaluationofaxialdisplacementbyimplantabutmentconnectiontypeaninvitrostudy AT sonkeunbada digitalevaluationofaxialdisplacementbyimplantabutmentconnectiontypeaninvitrostudy AT leekyubok digitalevaluationofaxialdisplacementbyimplantabutmentconnectiontypeaninvitrostudy |