Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

PURPOSE: To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS: Twenty models of missing mandibular le...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Sung-Jun, Son, KeunBaDa, Lee, Kyu-Bok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202430/
https://www.ncbi.nlm.nih.gov/pubmed/30370031
http://dx.doi.org/10.4047/jap.2018.10.5.388
_version_ 1783365679368372224
author Kim, Sung-Jun
Son, KeunBaDa
Lee, Kyu-Bok
author_facet Kim, Sung-Jun
Son, KeunBaDa
Lee, Kyu-Bok
author_sort Kim, Sung-Jun
collection PubMed
description PURPOSE: To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS: Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at 10 N·cm, simulating hand tightening, and then at the manufacturers' recommended torque (30 N·cm) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS: Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION: Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.
format Online
Article
Text
id pubmed-6202430
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-62024302018-10-26 Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study Kim, Sung-Jun Son, KeunBaDa Lee, Kyu-Bok J Adv Prosthodont Original Article PURPOSE: To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS: Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at 10 N·cm, simulating hand tightening, and then at the manufacturers' recommended torque (30 N·cm) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS: Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION: Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening. The Korean Academy of Prosthodontics 2018-10 2018-10-22 /pmc/articles/PMC6202430/ /pubmed/30370031 http://dx.doi.org/10.4047/jap.2018.10.5.388 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Sung-Jun
Son, KeunBaDa
Lee, Kyu-Bok
Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study
title Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study
title_full Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study
title_fullStr Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study
title_full_unstemmed Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study
title_short Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study
title_sort digital evaluation of axial displacement by implant-abutment connection type: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202430/
https://www.ncbi.nlm.nih.gov/pubmed/30370031
http://dx.doi.org/10.4047/jap.2018.10.5.388
work_keys_str_mv AT kimsungjun digitalevaluationofaxialdisplacementbyimplantabutmentconnectiontypeaninvitrostudy
AT sonkeunbada digitalevaluationofaxialdisplacementbyimplantabutmentconnectiontypeaninvitrostudy
AT leekyubok digitalevaluationofaxialdisplacementbyimplantabutmentconnectiontypeaninvitrostudy