Cargando…

Review of Catheter-Associated Urinary Tract Infections and In Vitro Urinary Tract Models

Catheter-associated urinary tract infections (CAUTIs) are one of the most common nosocomial infections and can lead to numerous medical complications from the mild catheter encrustation and bladder stones to the severe septicaemia, endotoxic shock, and pyelonephritis. Catheters are one of the most c...

Descripción completa

Detalles Bibliográficos
Autores principales: Cortese, Yvonne J., Wagner, Victoria E., Tierney, Morgan, Devine, Declan, Fogarty, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6204192/
https://www.ncbi.nlm.nih.gov/pubmed/30405898
http://dx.doi.org/10.1155/2018/2986742
_version_ 1783366006566027264
author Cortese, Yvonne J.
Wagner, Victoria E.
Tierney, Morgan
Devine, Declan
Fogarty, Andrew
author_facet Cortese, Yvonne J.
Wagner, Victoria E.
Tierney, Morgan
Devine, Declan
Fogarty, Andrew
author_sort Cortese, Yvonne J.
collection PubMed
description Catheter-associated urinary tract infections (CAUTIs) are one of the most common nosocomial infections and can lead to numerous medical complications from the mild catheter encrustation and bladder stones to the severe septicaemia, endotoxic shock, and pyelonephritis. Catheters are one of the most commonly used medical devices in the world and can be characterised as either indwelling (ID) or intermittent catheters (IC). The primary challenges in the use of IDs are biofilm formation and encrustation. ICs are increasingly seen as a solution to the complications caused by IDs as ICs pose no risk of biofilm formation due to their short time in the body and a lower risk of bladder stone formation. Research on IDs has focused on the use of antimicrobial and antibiofilm compounds, while research on ICs has focused on preventing bacteria entering the urinary tract or coming into contact with the catheter. There is an urgent need for in vitro urinary tract models to facilitate faster research and development for CAUTI prevention. There are currently three urinary tract models that test IDs; however, there is only a single very limited model for testing ICs. There is currently no standardised urinary tract model to test the efficacies of ICs.
format Online
Article
Text
id pubmed-6204192
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-62041922018-11-07 Review of Catheter-Associated Urinary Tract Infections and In Vitro Urinary Tract Models Cortese, Yvonne J. Wagner, Victoria E. Tierney, Morgan Devine, Declan Fogarty, Andrew J Healthc Eng Review Article Catheter-associated urinary tract infections (CAUTIs) are one of the most common nosocomial infections and can lead to numerous medical complications from the mild catheter encrustation and bladder stones to the severe septicaemia, endotoxic shock, and pyelonephritis. Catheters are one of the most commonly used medical devices in the world and can be characterised as either indwelling (ID) or intermittent catheters (IC). The primary challenges in the use of IDs are biofilm formation and encrustation. ICs are increasingly seen as a solution to the complications caused by IDs as ICs pose no risk of biofilm formation due to their short time in the body and a lower risk of bladder stone formation. Research on IDs has focused on the use of antimicrobial and antibiofilm compounds, while research on ICs has focused on preventing bacteria entering the urinary tract or coming into contact with the catheter. There is an urgent need for in vitro urinary tract models to facilitate faster research and development for CAUTI prevention. There are currently three urinary tract models that test IDs; however, there is only a single very limited model for testing ICs. There is currently no standardised urinary tract model to test the efficacies of ICs. Hindawi 2018-10-14 /pmc/articles/PMC6204192/ /pubmed/30405898 http://dx.doi.org/10.1155/2018/2986742 Text en Copyright © 2018 Yvonne J. Cortese et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Cortese, Yvonne J.
Wagner, Victoria E.
Tierney, Morgan
Devine, Declan
Fogarty, Andrew
Review of Catheter-Associated Urinary Tract Infections and In Vitro Urinary Tract Models
title Review of Catheter-Associated Urinary Tract Infections and In Vitro Urinary Tract Models
title_full Review of Catheter-Associated Urinary Tract Infections and In Vitro Urinary Tract Models
title_fullStr Review of Catheter-Associated Urinary Tract Infections and In Vitro Urinary Tract Models
title_full_unstemmed Review of Catheter-Associated Urinary Tract Infections and In Vitro Urinary Tract Models
title_short Review of Catheter-Associated Urinary Tract Infections and In Vitro Urinary Tract Models
title_sort review of catheter-associated urinary tract infections and in vitro urinary tract models
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6204192/
https://www.ncbi.nlm.nih.gov/pubmed/30405898
http://dx.doi.org/10.1155/2018/2986742
work_keys_str_mv AT corteseyvonnej reviewofcatheterassociatedurinarytractinfectionsandinvitrourinarytractmodels
AT wagnervictoriae reviewofcatheterassociatedurinarytractinfectionsandinvitrourinarytractmodels
AT tierneymorgan reviewofcatheterassociatedurinarytractinfectionsandinvitrourinarytractmodels
AT devinedeclan reviewofcatheterassociatedurinarytractinfectionsandinvitrourinarytractmodels
AT fogartyandrew reviewofcatheterassociatedurinarytractinfectionsandinvitrourinarytractmodels