Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement
BACKGROUND: Common carotid artery lumen diameter (LD) ultrasound measurement systems are either manual or semi-automated and lack reproducibility and variability studies. This pilot study presents an automated and cloud-based LD measurements software system (AtheroCloud) and evaluates its: (i) intra...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6205023/ https://www.ncbi.nlm.nih.gov/pubmed/30392503 http://dx.doi.org/10.1016/j.ihj.2018.01.024 |
_version_ | 1783366129684578304 |
---|---|
author | Saba, Luca Banchhor, Sumit K. Araki, Tadashi Viskovic, Klaudija Londhe, Narendra D. Laird, John R. Suri, Harman S. Suri, Jasjit S. |
author_facet | Saba, Luca Banchhor, Sumit K. Araki, Tadashi Viskovic, Klaudija Londhe, Narendra D. Laird, John R. Suri, Harman S. Suri, Jasjit S. |
author_sort | Saba, Luca |
collection | PubMed |
description | BACKGROUND: Common carotid artery lumen diameter (LD) ultrasound measurement systems are either manual or semi-automated and lack reproducibility and variability studies. This pilot study presents an automated and cloud-based LD measurements software system (AtheroCloud) and evaluates its: (i) intra/inter-operator reproducibility and (ii) intra/inter-observer variability. METHODS: 100 patients (83 M, mean age: 68 ± 11 years), IRB approved, consisted of L/R CCA artery (200 ultrasound images), acquired using a 7.5-MHz linear transducer. The intra/inter-operator reproducibility was verified using three operator’s readings. Near-wall and far carotid wall borders were manually traced by two observers for intra/inter-observer variability analysis. RESULTS: The mean coefficient of correlation (CC) for intra- and inter-operator reproducibility between all the three automated reading pairs were: 0.99 (P < 0.0001) and 0.97 (P < 0.0001), respectively. The mean CC for intra- and inter-observer variability between both the manual reading pairs were 0.98 (P < 0.0001) and 0.98 (P < 0.0001), respectively. The Figure-of-Merit between the mean of the three automated readings against the four manuals were 98.32%, 99.50%, 98.94% and 98.49%, respectively. CONCLUSIONS: The AtheroCloud LD measurement system showed high intra/inter-operator reproducibility hence can be adapted for vascular screening mode or pharmaceutical clinical trial mode. |
format | Online Article Text |
id | pubmed-6205023 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-62050232019-09-01 Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement Saba, Luca Banchhor, Sumit K. Araki, Tadashi Viskovic, Klaudija Londhe, Narendra D. Laird, John R. Suri, Harman S. Suri, Jasjit S. Indian Heart J Cardiac Imaging BACKGROUND: Common carotid artery lumen diameter (LD) ultrasound measurement systems are either manual or semi-automated and lack reproducibility and variability studies. This pilot study presents an automated and cloud-based LD measurements software system (AtheroCloud) and evaluates its: (i) intra/inter-operator reproducibility and (ii) intra/inter-observer variability. METHODS: 100 patients (83 M, mean age: 68 ± 11 years), IRB approved, consisted of L/R CCA artery (200 ultrasound images), acquired using a 7.5-MHz linear transducer. The intra/inter-operator reproducibility was verified using three operator’s readings. Near-wall and far carotid wall borders were manually traced by two observers for intra/inter-observer variability analysis. RESULTS: The mean coefficient of correlation (CC) for intra- and inter-operator reproducibility between all the three automated reading pairs were: 0.99 (P < 0.0001) and 0.97 (P < 0.0001), respectively. The mean CC for intra- and inter-observer variability between both the manual reading pairs were 0.98 (P < 0.0001) and 0.98 (P < 0.0001), respectively. The Figure-of-Merit between the mean of the three automated readings against the four manuals were 98.32%, 99.50%, 98.94% and 98.49%, respectively. CONCLUSIONS: The AtheroCloud LD measurement system showed high intra/inter-operator reproducibility hence can be adapted for vascular screening mode or pharmaceutical clinical trial mode. Elsevier 2018 2018-01-31 /pmc/articles/PMC6205023/ /pubmed/30392503 http://dx.doi.org/10.1016/j.ihj.2018.01.024 Text en © 2018 Published by Elsevier B.V. on behalf of Cardiological Society of India. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Cardiac Imaging Saba, Luca Banchhor, Sumit K. Araki, Tadashi Viskovic, Klaudija Londhe, Narendra D. Laird, John R. Suri, Harman S. Suri, Jasjit S. Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement |
title | Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement |
title_full | Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement |
title_fullStr | Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement |
title_full_unstemmed | Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement |
title_short | Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement |
title_sort | intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement |
topic | Cardiac Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6205023/ https://www.ncbi.nlm.nih.gov/pubmed/30392503 http://dx.doi.org/10.1016/j.ihj.2018.01.024 |
work_keys_str_mv | AT sabaluca intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement AT banchhorsumitk intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement AT arakitadashi intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement AT viskovicklaudija intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement AT londhenarendrad intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement AT lairdjohnr intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement AT suriharmans intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement AT surijasjits intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement |