Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement

BACKGROUND: Common carotid artery lumen diameter (LD) ultrasound measurement systems are either manual or semi-automated and lack reproducibility and variability studies. This pilot study presents an automated and cloud-based LD measurements software system (AtheroCloud) and evaluates its: (i) intra...

Descripción completa

Detalles Bibliográficos
Autores principales: Saba, Luca, Banchhor, Sumit K., Araki, Tadashi, Viskovic, Klaudija, Londhe, Narendra D., Laird, John R., Suri, Harman S., Suri, Jasjit S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6205023/
https://www.ncbi.nlm.nih.gov/pubmed/30392503
http://dx.doi.org/10.1016/j.ihj.2018.01.024
_version_ 1783366129684578304
author Saba, Luca
Banchhor, Sumit K.
Araki, Tadashi
Viskovic, Klaudija
Londhe, Narendra D.
Laird, John R.
Suri, Harman S.
Suri, Jasjit S.
author_facet Saba, Luca
Banchhor, Sumit K.
Araki, Tadashi
Viskovic, Klaudija
Londhe, Narendra D.
Laird, John R.
Suri, Harman S.
Suri, Jasjit S.
author_sort Saba, Luca
collection PubMed
description BACKGROUND: Common carotid artery lumen diameter (LD) ultrasound measurement systems are either manual or semi-automated and lack reproducibility and variability studies. This pilot study presents an automated and cloud-based LD measurements software system (AtheroCloud) and evaluates its: (i) intra/inter-operator reproducibility and (ii) intra/inter-observer variability. METHODS: 100 patients (83 M, mean age: 68 ± 11 years), IRB approved, consisted of L/R CCA artery (200 ultrasound images), acquired using a 7.5-MHz linear transducer. The intra/inter-operator reproducibility was verified using three operator’s readings. Near-wall and far carotid wall borders were manually traced by two observers for intra/inter-observer variability analysis. RESULTS: The mean coefficient of correlation (CC) for intra- and inter-operator reproducibility between all the three automated reading pairs were: 0.99 (P < 0.0001) and 0.97 (P < 0.0001), respectively. The mean CC for intra- and inter-observer variability between both the manual reading pairs were 0.98 (P < 0.0001) and 0.98 (P < 0.0001), respectively. The Figure-of-Merit between the mean of the three automated readings against the four manuals were 98.32%, 99.50%, 98.94% and 98.49%, respectively. CONCLUSIONS: The AtheroCloud LD measurement system showed high intra/inter-operator reproducibility hence can be adapted for vascular screening mode or pharmaceutical clinical trial mode.
format Online
Article
Text
id pubmed-6205023
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-62050232019-09-01 Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement Saba, Luca Banchhor, Sumit K. Araki, Tadashi Viskovic, Klaudija Londhe, Narendra D. Laird, John R. Suri, Harman S. Suri, Jasjit S. Indian Heart J Cardiac Imaging BACKGROUND: Common carotid artery lumen diameter (LD) ultrasound measurement systems are either manual or semi-automated and lack reproducibility and variability studies. This pilot study presents an automated and cloud-based LD measurements software system (AtheroCloud) and evaluates its: (i) intra/inter-operator reproducibility and (ii) intra/inter-observer variability. METHODS: 100 patients (83 M, mean age: 68 ± 11 years), IRB approved, consisted of L/R CCA artery (200 ultrasound images), acquired using a 7.5-MHz linear transducer. The intra/inter-operator reproducibility was verified using three operator’s readings. Near-wall and far carotid wall borders were manually traced by two observers for intra/inter-observer variability analysis. RESULTS: The mean coefficient of correlation (CC) for intra- and inter-operator reproducibility between all the three automated reading pairs were: 0.99 (P < 0.0001) and 0.97 (P < 0.0001), respectively. The mean CC for intra- and inter-observer variability between both the manual reading pairs were 0.98 (P < 0.0001) and 0.98 (P < 0.0001), respectively. The Figure-of-Merit between the mean of the three automated readings against the four manuals were 98.32%, 99.50%, 98.94% and 98.49%, respectively. CONCLUSIONS: The AtheroCloud LD measurement system showed high intra/inter-operator reproducibility hence can be adapted for vascular screening mode or pharmaceutical clinical trial mode. Elsevier 2018 2018-01-31 /pmc/articles/PMC6205023/ /pubmed/30392503 http://dx.doi.org/10.1016/j.ihj.2018.01.024 Text en © 2018 Published by Elsevier B.V. on behalf of Cardiological Society of India. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Cardiac Imaging
Saba, Luca
Banchhor, Sumit K.
Araki, Tadashi
Viskovic, Klaudija
Londhe, Narendra D.
Laird, John R.
Suri, Harman S.
Suri, Jasjit S.
Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement
title Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement
title_full Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement
title_fullStr Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement
title_full_unstemmed Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement
title_short Intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement
title_sort intra- and inter-operator reproducibility of automated cloud-based carotid lumen diameter ultrasound measurement
topic Cardiac Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6205023/
https://www.ncbi.nlm.nih.gov/pubmed/30392503
http://dx.doi.org/10.1016/j.ihj.2018.01.024
work_keys_str_mv AT sabaluca intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement
AT banchhorsumitk intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement
AT arakitadashi intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement
AT viskovicklaudija intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement
AT londhenarendrad intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement
AT lairdjohnr intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement
AT suriharmans intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement
AT surijasjits intraandinteroperatorreproducibilityofautomatedcloudbasedcarotidlumendiameterultrasoundmeasurement