Cargando…
Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio
BACKGROUND: The Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines recommend intra-access flow (Qa) measurement as the preferred vascular access surveillance method over static intra-access pressure ratio (SIAPR). Recently, it has become possible to perform Qa measurement during hemodialy...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6205593/ https://www.ncbi.nlm.nih.gov/pubmed/30372435 http://dx.doi.org/10.1371/journal.pone.0204630 |
_version_ | 1783366209750695936 |
---|---|
author | Choi, Yoo Jin Lee, Young-Ki Park, Hayne Cho Kim, Eun Yi Cho, Ajin Han, Chaehoon Choi, Sun Ryoung Kim, Hanmyun Kim, Eun-Jung Yoon, Jong-Woo Noh, Jung-Woo |
author_facet | Choi, Yoo Jin Lee, Young-Ki Park, Hayne Cho Kim, Eun Yi Cho, Ajin Han, Chaehoon Choi, Sun Ryoung Kim, Hanmyun Kim, Eun-Jung Yoon, Jong-Woo Noh, Jung-Woo |
author_sort | Choi, Yoo Jin |
collection | PubMed |
description | BACKGROUND: The Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines recommend intra-access flow (Qa) measurement as the preferred vascular access surveillance method over static intra-access pressure ratio (SIAPR). Recently, it has become possible to perform Qa measurement during hemodialysis using thermodilution method called blood temperature monitoring (BTM) with the Twister device. The aim of this study was to investigate the correlation between Qa by BTM and SIAPR and to compare the performance of two tests in prediction of vascular access stenosis. METHODS: The study was performed from January 2016 to November 2017 and included 97 patients with arteriovenous fistulas (AVF). Qa by BTM and SIAPR were simultaneously measured every 1~3 months with a total of 449 measurements during study period. RESULTS: In our study population, mean age was 59.9±10.0 years and 61.9% were diabetes. The mean Qa obtained by BTM was 1186±588 mL/min. There was no correlation between Qa by BTM and venous SIAPR (r = 0.061, P = 0.196). Angiography identified 36 stenotic AVFs (37.1%) among the study subjects. They included 13 cases with only inflow stenosis, 6 with only outflow stenosis, and 17 with stenosis on both sides. Receiver-operating characteristic (ROC) curve analysis showed that Qa by BTM had higher discriminative ability to diagnose vascular access stenosis compared to SIAPR (P <0.001). The Qa less than 583 mL/min showed the highest diagnostic accuracy in vascular stenosis prediction. CONCLUSION: Intradialytic measurement of Qa by BTM showed better diagnostic power over venous SIAPR in prediction of vascular access stenosis. |
format | Online Article Text |
id | pubmed-6205593 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-62055932018-11-19 Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio Choi, Yoo Jin Lee, Young-Ki Park, Hayne Cho Kim, Eun Yi Cho, Ajin Han, Chaehoon Choi, Sun Ryoung Kim, Hanmyun Kim, Eun-Jung Yoon, Jong-Woo Noh, Jung-Woo PLoS One Research Article BACKGROUND: The Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines recommend intra-access flow (Qa) measurement as the preferred vascular access surveillance method over static intra-access pressure ratio (SIAPR). Recently, it has become possible to perform Qa measurement during hemodialysis using thermodilution method called blood temperature monitoring (BTM) with the Twister device. The aim of this study was to investigate the correlation between Qa by BTM and SIAPR and to compare the performance of two tests in prediction of vascular access stenosis. METHODS: The study was performed from January 2016 to November 2017 and included 97 patients with arteriovenous fistulas (AVF). Qa by BTM and SIAPR were simultaneously measured every 1~3 months with a total of 449 measurements during study period. RESULTS: In our study population, mean age was 59.9±10.0 years and 61.9% were diabetes. The mean Qa obtained by BTM was 1186±588 mL/min. There was no correlation between Qa by BTM and venous SIAPR (r = 0.061, P = 0.196). Angiography identified 36 stenotic AVFs (37.1%) among the study subjects. They included 13 cases with only inflow stenosis, 6 with only outflow stenosis, and 17 with stenosis on both sides. Receiver-operating characteristic (ROC) curve analysis showed that Qa by BTM had higher discriminative ability to diagnose vascular access stenosis compared to SIAPR (P <0.001). The Qa less than 583 mL/min showed the highest diagnostic accuracy in vascular stenosis prediction. CONCLUSION: Intradialytic measurement of Qa by BTM showed better diagnostic power over venous SIAPR in prediction of vascular access stenosis. Public Library of Science 2018-10-29 /pmc/articles/PMC6205593/ /pubmed/30372435 http://dx.doi.org/10.1371/journal.pone.0204630 Text en © 2018 Choi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Choi, Yoo Jin Lee, Young-Ki Park, Hayne Cho Kim, Eun Yi Cho, Ajin Han, Chaehoon Choi, Sun Ryoung Kim, Hanmyun Kim, Eun-Jung Yoon, Jong-Woo Noh, Jung-Woo Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio |
title | Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio |
title_full | Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio |
title_fullStr | Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio |
title_full_unstemmed | Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio |
title_short | Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio |
title_sort | prediction of vascular access stenosis: blood temperature monitoring with the twister versus static intra-access pressure ratio |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6205593/ https://www.ncbi.nlm.nih.gov/pubmed/30372435 http://dx.doi.org/10.1371/journal.pone.0204630 |
work_keys_str_mv | AT choiyoojin predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT leeyoungki predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT parkhaynecho predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT kimeunyi predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT choajin predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT hanchaehoon predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT choisunryoung predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT kimhanmyun predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT kimeunjung predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT yoonjongwoo predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio AT nohjungwoo predictionofvascularaccessstenosisbloodtemperaturemonitoringwiththetwisterversusstaticintraaccesspressureratio |