Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants
INTRODUCTION: The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant sy...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6209715/ https://www.ncbi.nlm.nih.gov/pubmed/30393498 http://dx.doi.org/10.5114/aoms.2018.79007 |
_version_ | 1783366953984851968 |
---|---|
author | Arnholdt, Joerg Kamawal, Yama Holzapfel, Boris Michael Ripp, Axel Rudert, Maximilian Steinert, Andre Friedrich |
author_facet | Arnholdt, Joerg Kamawal, Yama Holzapfel, Boris Michael Ripp, Axel Rudert, Maximilian Steinert, Andre Friedrich |
author_sort | Arnholdt, Joerg |
collection | PubMed |
description | INTRODUCTION: The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored. MATERIAL AND METHODS: In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novel patient-specific fixed-bearing bi-compartmental knee resurfacing system using custom-made implants and instruments. Utilizing standardized pre- and postoperative radiographic analyses (based on anterior-posterior and lateral, anterior-posterior weight-bearing full-length radiographs, patella skyline views and preoperative computed tomography (CT) scanning) implant fit and positioning as well as correction of the mechanical axis (hip-knee-ankle angle, HKA) were determined. RESULTS: On average, HKA was corrected from 173.4 ±3.47° preoperatively to 179.4 ±2.85° postoperatively. The coronal femoro-tibial angle was corrected on average 5.61°. The preoperative tibial slope measured on lateral views was 6.38 ±2.4°, while the average slope in the CT-based planning protocol (iView) was 6.14 ±2.40°. Postoperative lateral tibial slope was determined to be 5.77 ±1.97°. The thickness of the posterior femoral cuts was measured intraoperatively and, in all cases, corresponded well to the targeted thickness of the cuts provided by the iView. The joint line was preserved in all cases and the average Insall-Salvati index was 1.078 ±0.11 pre- and 1.072 ±0.11 postoperatively. The fit of the implant components measured by over- or underhang was excellent throughout (< 1.01 mm). CONCLUSIONS: Custom-made bicompartmental knee arthroplasty can ensure optimized fitting and positioning of the implant with restoration of the leg axis. These implants could be considered as an alternative primary solution for knee surgeons treating bi-compartmental disease. |
format | Online Article Text |
id | pubmed-6209715 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-62097152018-11-02 Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants Arnholdt, Joerg Kamawal, Yama Holzapfel, Boris Michael Ripp, Axel Rudert, Maximilian Steinert, Andre Friedrich Arch Med Sci Clinical Research INTRODUCTION: The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored. MATERIAL AND METHODS: In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novel patient-specific fixed-bearing bi-compartmental knee resurfacing system using custom-made implants and instruments. Utilizing standardized pre- and postoperative radiographic analyses (based on anterior-posterior and lateral, anterior-posterior weight-bearing full-length radiographs, patella skyline views and preoperative computed tomography (CT) scanning) implant fit and positioning as well as correction of the mechanical axis (hip-knee-ankle angle, HKA) were determined. RESULTS: On average, HKA was corrected from 173.4 ±3.47° preoperatively to 179.4 ±2.85° postoperatively. The coronal femoro-tibial angle was corrected on average 5.61°. The preoperative tibial slope measured on lateral views was 6.38 ±2.4°, while the average slope in the CT-based planning protocol (iView) was 6.14 ±2.40°. Postoperative lateral tibial slope was determined to be 5.77 ±1.97°. The thickness of the posterior femoral cuts was measured intraoperatively and, in all cases, corresponded well to the targeted thickness of the cuts provided by the iView. The joint line was preserved in all cases and the average Insall-Salvati index was 1.078 ±0.11 pre- and 1.072 ±0.11 postoperatively. The fit of the implant components measured by over- or underhang was excellent throughout (< 1.01 mm). CONCLUSIONS: Custom-made bicompartmental knee arthroplasty can ensure optimized fitting and positioning of the implant with restoration of the leg axis. These implants could be considered as an alternative primary solution for knee surgeons treating bi-compartmental disease. Termedia Publishing House 2018-10-23 2018-10 /pmc/articles/PMC6209715/ /pubmed/30393498 http://dx.doi.org/10.5114/aoms.2018.79007 Text en Copyright: © 2018 Termedia & Banach http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Clinical Research Arnholdt, Joerg Kamawal, Yama Holzapfel, Boris Michael Ripp, Axel Rudert, Maximilian Steinert, Andre Friedrich Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants |
title | Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants |
title_full | Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants |
title_fullStr | Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants |
title_full_unstemmed | Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants |
title_short | Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants |
title_sort | evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6209715/ https://www.ncbi.nlm.nih.gov/pubmed/30393498 http://dx.doi.org/10.5114/aoms.2018.79007 |
work_keys_str_mv | AT arnholdtjoerg evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants AT kamawalyama evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants AT holzapfelborismichael evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants AT rippaxel evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants AT rudertmaximilian evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants AT steinertandrefriedrich evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants |