Cargando…

Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants

INTRODUCTION: The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant sy...

Descripción completa

Detalles Bibliográficos
Autores principales: Arnholdt, Joerg, Kamawal, Yama, Holzapfel, Boris Michael, Ripp, Axel, Rudert, Maximilian, Steinert, Andre Friedrich
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6209715/
https://www.ncbi.nlm.nih.gov/pubmed/30393498
http://dx.doi.org/10.5114/aoms.2018.79007
_version_ 1783366953984851968
author Arnholdt, Joerg
Kamawal, Yama
Holzapfel, Boris Michael
Ripp, Axel
Rudert, Maximilian
Steinert, Andre Friedrich
author_facet Arnholdt, Joerg
Kamawal, Yama
Holzapfel, Boris Michael
Ripp, Axel
Rudert, Maximilian
Steinert, Andre Friedrich
author_sort Arnholdt, Joerg
collection PubMed
description INTRODUCTION: The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored. MATERIAL AND METHODS: In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novel patient-specific fixed-bearing bi-compartmental knee resurfacing system using custom-made implants and instruments. Utilizing standardized pre- and postoperative radiographic analyses (based on anterior-posterior and lateral, anterior-posterior weight-bearing full-length radiographs, patella skyline views and preoperative computed tomography (CT) scanning) implant fit and positioning as well as correction of the mechanical axis (hip-knee-ankle angle, HKA) were determined. RESULTS: On average, HKA was corrected from 173.4 ±3.47° preoperatively to 179.4 ±2.85° postoperatively. The coronal femoro-tibial angle was corrected on average 5.61°. The preoperative tibial slope measured on lateral views was 6.38 ±2.4°, while the average slope in the CT-based planning protocol (iView) was 6.14 ±2.40°. Postoperative lateral tibial slope was determined to be 5.77 ±1.97°. The thickness of the posterior femoral cuts was measured intraoperatively and, in all cases, corresponded well to the targeted thickness of the cuts provided by the iView. The joint line was preserved in all cases and the average Insall-Salvati index was 1.078 ±0.11 pre- and 1.072 ±0.11 postoperatively. The fit of the implant components measured by over- or underhang was excellent throughout (< 1.01 mm). CONCLUSIONS: Custom-made bicompartmental knee arthroplasty can ensure optimized fitting and positioning of the implant with restoration of the leg axis. These implants could be considered as an alternative primary solution for knee surgeons treating bi-compartmental disease.
format Online
Article
Text
id pubmed-6209715
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-62097152018-11-02 Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants Arnholdt, Joerg Kamawal, Yama Holzapfel, Boris Michael Ripp, Axel Rudert, Maximilian Steinert, Andre Friedrich Arch Med Sci Clinical Research INTRODUCTION: The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored. MATERIAL AND METHODS: In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novel patient-specific fixed-bearing bi-compartmental knee resurfacing system using custom-made implants and instruments. Utilizing standardized pre- and postoperative radiographic analyses (based on anterior-posterior and lateral, anterior-posterior weight-bearing full-length radiographs, patella skyline views and preoperative computed tomography (CT) scanning) implant fit and positioning as well as correction of the mechanical axis (hip-knee-ankle angle, HKA) were determined. RESULTS: On average, HKA was corrected from 173.4 ±3.47° preoperatively to 179.4 ±2.85° postoperatively. The coronal femoro-tibial angle was corrected on average 5.61°. The preoperative tibial slope measured on lateral views was 6.38 ±2.4°, while the average slope in the CT-based planning protocol (iView) was 6.14 ±2.40°. Postoperative lateral tibial slope was determined to be 5.77 ±1.97°. The thickness of the posterior femoral cuts was measured intraoperatively and, in all cases, corresponded well to the targeted thickness of the cuts provided by the iView. The joint line was preserved in all cases and the average Insall-Salvati index was 1.078 ±0.11 pre- and 1.072 ±0.11 postoperatively. The fit of the implant components measured by over- or underhang was excellent throughout (< 1.01 mm). CONCLUSIONS: Custom-made bicompartmental knee arthroplasty can ensure optimized fitting and positioning of the implant with restoration of the leg axis. These implants could be considered as an alternative primary solution for knee surgeons treating bi-compartmental disease. Termedia Publishing House 2018-10-23 2018-10 /pmc/articles/PMC6209715/ /pubmed/30393498 http://dx.doi.org/10.5114/aoms.2018.79007 Text en Copyright: © 2018 Termedia & Banach http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Clinical Research
Arnholdt, Joerg
Kamawal, Yama
Holzapfel, Boris Michael
Ripp, Axel
Rudert, Maximilian
Steinert, Andre Friedrich
Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants
title Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants
title_full Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants
title_fullStr Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants
title_full_unstemmed Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants
title_short Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants
title_sort evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6209715/
https://www.ncbi.nlm.nih.gov/pubmed/30393498
http://dx.doi.org/10.5114/aoms.2018.79007
work_keys_str_mv AT arnholdtjoerg evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants
AT kamawalyama evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants
AT holzapfelborismichael evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants
AT rippaxel evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants
AT rudertmaximilian evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants
AT steinertandrefriedrich evaluationofimplantfitandfrontalplanealignmentafterbicompartmentalkneearthroplastyusingpatientspecificinstrumentsandimplants