Cargando…
Improving Cleaning and Disinfection of High-Touch Surfaces in Intensive Care during Carbapenem-Resistant Acinetobacter baumannii Endemo-Epidemic Situations
Aims: High-touch surfaces cleaning and disinfection require the adoption of effective and proper executed protocols, especially during carbapenem-resistant Acinetobacter baumannii (CRAB) endemo-epidemic situations. We evaluated the effectiveness and residual disinfectant activity of disposable pre-i...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6209904/ https://www.ncbi.nlm.nih.gov/pubmed/30347749 http://dx.doi.org/10.3390/ijerph15102305 |
Sumario: | Aims: High-touch surfaces cleaning and disinfection require the adoption of effective and proper executed protocols, especially during carbapenem-resistant Acinetobacter baumannii (CRAB) endemo-epidemic situations. We evaluated the effectiveness and residual disinfectant activity of disposable pre-impregnated wipes (Modified Operative Protocol, MOP) in reducing environmental bioburden versus a two-step Standard Operative Protocol (SOP) in a 12-bed Intensive Care Unit. Methods: Five high-touch surfaces were cleaned and disinfected either according to the SOP (alcohol-based cleaning and chlorine-based disinfection) or using quaternary ammonium compounds-based disposable wipes (MOP). Sampling was performed before each procedure and at 0.5, 2.5, 4.5 and 6.5 h after (560 sites). Total viable count (TVC) was evaluated according to Italian hygiene standard (<50 CFU/24 cm(2)). Clinical and environmental CRAB strains isolated were genotyped. Results: On non-electromedical surfaces the difference between TVC before procedure and at each of the following times was significant only for the MOP (p < 0.05, Wilcoxon test). Using the MOP, only 7.4% (10/135) of sites showed TVC >50 CFU/24 cm(2) (hygiene failures) versus 18.9% (25/132) after SOP (p < 0.05, Fisher’s Exact test). On infusion pumps a higher number of hygiene failures was observed after the SOP (7/44, 15.9%) compared with the MOP (4/45, 8.9%). Genotyping highlighted a common source of infection. Conclusion: On high-touch surfaces, the use of disposable wipes by in-house auxiliary nurses may represent a more effective alternative to standard cleaning and disinfection procedure performed by outsourced cleaning services, showing effectiveness in reducing microbial contamination and residual disinfection activity up to 6.5 h. |
---|