Cargando…

An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots—Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer

We report the preparation of poly (propylene imine) dendrimer (PPI) and CdTe/CdSe/ZnSe quantum dots (QDs) as a suitable platform for the development of an enzyme-based electrochemical cholesterol biosensor with enhanced analytical performance. The mercaptopropionic acid (MPA)-capped CdTe/CdSe/ZnSe Q...

Descripción completa

Detalles Bibliográficos
Autores principales: Mokwebo, Kefilwe Vanessa, Oluwafemi, Oluwatobi Samuel, Arotiba, Omotayo Ademola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6209991/
https://www.ncbi.nlm.nih.gov/pubmed/30304820
http://dx.doi.org/10.3390/s18103368
_version_ 1783367015234273280
author Mokwebo, Kefilwe Vanessa
Oluwafemi, Oluwatobi Samuel
Arotiba, Omotayo Ademola
author_facet Mokwebo, Kefilwe Vanessa
Oluwafemi, Oluwatobi Samuel
Arotiba, Omotayo Ademola
author_sort Mokwebo, Kefilwe Vanessa
collection PubMed
description We report the preparation of poly (propylene imine) dendrimer (PPI) and CdTe/CdSe/ZnSe quantum dots (QDs) as a suitable platform for the development of an enzyme-based electrochemical cholesterol biosensor with enhanced analytical performance. The mercaptopropionic acid (MPA)-capped CdTe/CdSe/ZnSe QDs was synthesized in an aqueous phase and characterized using photoluminescence (PL) spectroscopy, ultraviolet-visible (UV-Vis) spectroscopy, transmission electron microscopy (TEM), X-ray power diffraction (XRD), energy dispersive X-ray (EDX) spectroscopy. The absorption and emission maxima of the QDs red shifted as the reaction time and shell growth increased, indicating the formation of CdTe/CdSe/ZnSe QDs. PPI was electrodeposited on a glassy carbon electrode followed by the deposition (by deep coating) attachment of the QDs onto the PPI dendrimer modified electrode using 1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC), and N-hydroxysuccinimide (NHS) as a coupling agent. The biosensor was prepared by incubating the PPI/QDs modified electrode into a solution of cholesterol oxidase (ChOx) for 6 h. The modified electrodes were characterized by voltammetry and impedance spectroscopy. Since efficient electron transfer process between the enzyme cholesterol oxidase (ChOx) and the PPI/QDs-modified electrode was achieved, the cholesterol biosensor (GCE/PPI/QDs/ChOx) was able to detect cholesterol in the range 0.1–10 mM with a detection limit (LOD) of 0.075 mM and sensitivity of 111.16 μA mM(−1) cm(−2). The biosensor was stable for over a month and had greater selectivity towards the cholesterol molecule.
format Online
Article
Text
id pubmed-6209991
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62099912018-11-02 An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots—Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer Mokwebo, Kefilwe Vanessa Oluwafemi, Oluwatobi Samuel Arotiba, Omotayo Ademola Sensors (Basel) Article We report the preparation of poly (propylene imine) dendrimer (PPI) and CdTe/CdSe/ZnSe quantum dots (QDs) as a suitable platform for the development of an enzyme-based electrochemical cholesterol biosensor with enhanced analytical performance. The mercaptopropionic acid (MPA)-capped CdTe/CdSe/ZnSe QDs was synthesized in an aqueous phase and characterized using photoluminescence (PL) spectroscopy, ultraviolet-visible (UV-Vis) spectroscopy, transmission electron microscopy (TEM), X-ray power diffraction (XRD), energy dispersive X-ray (EDX) spectroscopy. The absorption and emission maxima of the QDs red shifted as the reaction time and shell growth increased, indicating the formation of CdTe/CdSe/ZnSe QDs. PPI was electrodeposited on a glassy carbon electrode followed by the deposition (by deep coating) attachment of the QDs onto the PPI dendrimer modified electrode using 1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC), and N-hydroxysuccinimide (NHS) as a coupling agent. The biosensor was prepared by incubating the PPI/QDs modified electrode into a solution of cholesterol oxidase (ChOx) for 6 h. The modified electrodes were characterized by voltammetry and impedance spectroscopy. Since efficient electron transfer process between the enzyme cholesterol oxidase (ChOx) and the PPI/QDs-modified electrode was achieved, the cholesterol biosensor (GCE/PPI/QDs/ChOx) was able to detect cholesterol in the range 0.1–10 mM with a detection limit (LOD) of 0.075 mM and sensitivity of 111.16 μA mM(−1) cm(−2). The biosensor was stable for over a month and had greater selectivity towards the cholesterol molecule. MDPI 2018-10-09 /pmc/articles/PMC6209991/ /pubmed/30304820 http://dx.doi.org/10.3390/s18103368 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mokwebo, Kefilwe Vanessa
Oluwafemi, Oluwatobi Samuel
Arotiba, Omotayo Ademola
An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots—Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer
title An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots—Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer
title_full An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots—Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer
title_fullStr An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots—Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer
title_full_unstemmed An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots—Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer
title_short An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots—Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer
title_sort electrochemical cholesterol biosensor based on a cdte/cdse/znse quantum dots—poly (propylene imine) dendrimer nanocomposite immobilisation layer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6209991/
https://www.ncbi.nlm.nih.gov/pubmed/30304820
http://dx.doi.org/10.3390/s18103368
work_keys_str_mv AT mokwebokefilwevanessa anelectrochemicalcholesterolbiosensorbasedonacdtecdseznsequantumdotspolypropyleneiminedendrimernanocompositeimmobilisationlayer
AT oluwafemioluwatobisamuel anelectrochemicalcholesterolbiosensorbasedonacdtecdseznsequantumdotspolypropyleneiminedendrimernanocompositeimmobilisationlayer
AT arotibaomotayoademola anelectrochemicalcholesterolbiosensorbasedonacdtecdseznsequantumdotspolypropyleneiminedendrimernanocompositeimmobilisationlayer
AT mokwebokefilwevanessa electrochemicalcholesterolbiosensorbasedonacdtecdseznsequantumdotspolypropyleneiminedendrimernanocompositeimmobilisationlayer
AT oluwafemioluwatobisamuel electrochemicalcholesterolbiosensorbasedonacdtecdseznsequantumdotspolypropyleneiminedendrimernanocompositeimmobilisationlayer
AT arotibaomotayoademola electrochemicalcholesterolbiosensorbasedonacdtecdseznsequantumdotspolypropyleneiminedendrimernanocompositeimmobilisationlayer