Cargando…

Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions

Acute hypoxia changes the redox-state of pulmonary arterial smooth muscle cells (PASMCs). This might influence the activity of redox-sensitive voltage-gated K(+)-channels (Kv-channels) whose inhibition initiates hypoxic pulmonary vasoconstriction (HPV). However, the molecular mechanism of how hypoxi...

Descripción completa

Detalles Bibliográficos
Autores principales: Knoepp, Fenja, Wahl, Joel, Andersson, Anders, Borg, Johan, Weissmann, Norbert, Ramser, Kerstin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6210661/
https://www.ncbi.nlm.nih.gov/pubmed/30261634
http://dx.doi.org/10.3390/s18103238
_version_ 1783367166919180288
author Knoepp, Fenja
Wahl, Joel
Andersson, Anders
Borg, Johan
Weissmann, Norbert
Ramser, Kerstin
author_facet Knoepp, Fenja
Wahl, Joel
Andersson, Anders
Borg, Johan
Weissmann, Norbert
Ramser, Kerstin
author_sort Knoepp, Fenja
collection PubMed
description Acute hypoxia changes the redox-state of pulmonary arterial smooth muscle cells (PASMCs). This might influence the activity of redox-sensitive voltage-gated K(+)-channels (Kv-channels) whose inhibition initiates hypoxic pulmonary vasoconstriction (HPV). However, the molecular mechanism of how hypoxia—or the subsequent change in the cellular redox-state—inhibits Kv-channels remains elusive. For this purpose, a new multifunctional gas-tight microfluidic system was developed enabling simultaneous single-cell Raman spectroscopic studies (to sense the redox-state under normoxic/hypoxic conditions) and patch-clamp experiments (to study the Kv-channel activity). The performance of the system was tested by optically recording the O(2)-content and taking Raman spectra on murine PASMCs under normoxic/hypoxic conditions or in the presence of H(2)O(2). Oxygen sensing showed that hypoxic levels in the gas-tight microfluidic system were achieved faster, more stable and significantly lower compared to a conventional open system (1.6 ± 0.2%, respectively 6.7 ± 0.7%, n = 6, p < 0.001). Raman spectra revealed that the redistribution of biomarkers (cytochromes, FeS, myoglobin and NADH) under hypoxic/normoxic conditions were improved in the gas-tight microfluidic system (p-values from 0.00% to 16.30%) compared to the open system (p-value from 0.01% to 98.42%). In conclusion, the new redox sensor holds promise for future experiments that may elucidate the role of Kv-channels during HPV.
format Online
Article
Text
id pubmed-6210661
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62106612018-11-02 Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions Knoepp, Fenja Wahl, Joel Andersson, Anders Borg, Johan Weissmann, Norbert Ramser, Kerstin Sensors (Basel) Article Acute hypoxia changes the redox-state of pulmonary arterial smooth muscle cells (PASMCs). This might influence the activity of redox-sensitive voltage-gated K(+)-channels (Kv-channels) whose inhibition initiates hypoxic pulmonary vasoconstriction (HPV). However, the molecular mechanism of how hypoxia—or the subsequent change in the cellular redox-state—inhibits Kv-channels remains elusive. For this purpose, a new multifunctional gas-tight microfluidic system was developed enabling simultaneous single-cell Raman spectroscopic studies (to sense the redox-state under normoxic/hypoxic conditions) and patch-clamp experiments (to study the Kv-channel activity). The performance of the system was tested by optically recording the O(2)-content and taking Raman spectra on murine PASMCs under normoxic/hypoxic conditions or in the presence of H(2)O(2). Oxygen sensing showed that hypoxic levels in the gas-tight microfluidic system were achieved faster, more stable and significantly lower compared to a conventional open system (1.6 ± 0.2%, respectively 6.7 ± 0.7%, n = 6, p < 0.001). Raman spectra revealed that the redistribution of biomarkers (cytochromes, FeS, myoglobin and NADH) under hypoxic/normoxic conditions were improved in the gas-tight microfluidic system (p-values from 0.00% to 16.30%) compared to the open system (p-value from 0.01% to 98.42%). In conclusion, the new redox sensor holds promise for future experiments that may elucidate the role of Kv-channels during HPV. MDPI 2018-09-26 /pmc/articles/PMC6210661/ /pubmed/30261634 http://dx.doi.org/10.3390/s18103238 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Knoepp, Fenja
Wahl, Joel
Andersson, Anders
Borg, Johan
Weissmann, Norbert
Ramser, Kerstin
Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions
title Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions
title_full Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions
title_fullStr Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions
title_full_unstemmed Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions
title_short Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions
title_sort development of a gas-tight microfluidic system for raman sensing of single pulmonary arterial smooth muscle cells under normoxic/hypoxic conditions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6210661/
https://www.ncbi.nlm.nih.gov/pubmed/30261634
http://dx.doi.org/10.3390/s18103238
work_keys_str_mv AT knoeppfenja developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions
AT wahljoel developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions
AT anderssonanders developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions
AT borgjohan developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions
AT weissmannnorbert developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions
AT ramserkerstin developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions