Cargando…
Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions
Acute hypoxia changes the redox-state of pulmonary arterial smooth muscle cells (PASMCs). This might influence the activity of redox-sensitive voltage-gated K(+)-channels (Kv-channels) whose inhibition initiates hypoxic pulmonary vasoconstriction (HPV). However, the molecular mechanism of how hypoxi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6210661/ https://www.ncbi.nlm.nih.gov/pubmed/30261634 http://dx.doi.org/10.3390/s18103238 |
_version_ | 1783367166919180288 |
---|---|
author | Knoepp, Fenja Wahl, Joel Andersson, Anders Borg, Johan Weissmann, Norbert Ramser, Kerstin |
author_facet | Knoepp, Fenja Wahl, Joel Andersson, Anders Borg, Johan Weissmann, Norbert Ramser, Kerstin |
author_sort | Knoepp, Fenja |
collection | PubMed |
description | Acute hypoxia changes the redox-state of pulmonary arterial smooth muscle cells (PASMCs). This might influence the activity of redox-sensitive voltage-gated K(+)-channels (Kv-channels) whose inhibition initiates hypoxic pulmonary vasoconstriction (HPV). However, the molecular mechanism of how hypoxia—or the subsequent change in the cellular redox-state—inhibits Kv-channels remains elusive. For this purpose, a new multifunctional gas-tight microfluidic system was developed enabling simultaneous single-cell Raman spectroscopic studies (to sense the redox-state under normoxic/hypoxic conditions) and patch-clamp experiments (to study the Kv-channel activity). The performance of the system was tested by optically recording the O(2)-content and taking Raman spectra on murine PASMCs under normoxic/hypoxic conditions or in the presence of H(2)O(2). Oxygen sensing showed that hypoxic levels in the gas-tight microfluidic system were achieved faster, more stable and significantly lower compared to a conventional open system (1.6 ± 0.2%, respectively 6.7 ± 0.7%, n = 6, p < 0.001). Raman spectra revealed that the redistribution of biomarkers (cytochromes, FeS, myoglobin and NADH) under hypoxic/normoxic conditions were improved in the gas-tight microfluidic system (p-values from 0.00% to 16.30%) compared to the open system (p-value from 0.01% to 98.42%). In conclusion, the new redox sensor holds promise for future experiments that may elucidate the role of Kv-channels during HPV. |
format | Online Article Text |
id | pubmed-6210661 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62106612018-11-02 Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions Knoepp, Fenja Wahl, Joel Andersson, Anders Borg, Johan Weissmann, Norbert Ramser, Kerstin Sensors (Basel) Article Acute hypoxia changes the redox-state of pulmonary arterial smooth muscle cells (PASMCs). This might influence the activity of redox-sensitive voltage-gated K(+)-channels (Kv-channels) whose inhibition initiates hypoxic pulmonary vasoconstriction (HPV). However, the molecular mechanism of how hypoxia—or the subsequent change in the cellular redox-state—inhibits Kv-channels remains elusive. For this purpose, a new multifunctional gas-tight microfluidic system was developed enabling simultaneous single-cell Raman spectroscopic studies (to sense the redox-state under normoxic/hypoxic conditions) and patch-clamp experiments (to study the Kv-channel activity). The performance of the system was tested by optically recording the O(2)-content and taking Raman spectra on murine PASMCs under normoxic/hypoxic conditions or in the presence of H(2)O(2). Oxygen sensing showed that hypoxic levels in the gas-tight microfluidic system were achieved faster, more stable and significantly lower compared to a conventional open system (1.6 ± 0.2%, respectively 6.7 ± 0.7%, n = 6, p < 0.001). Raman spectra revealed that the redistribution of biomarkers (cytochromes, FeS, myoglobin and NADH) under hypoxic/normoxic conditions were improved in the gas-tight microfluidic system (p-values from 0.00% to 16.30%) compared to the open system (p-value from 0.01% to 98.42%). In conclusion, the new redox sensor holds promise for future experiments that may elucidate the role of Kv-channels during HPV. MDPI 2018-09-26 /pmc/articles/PMC6210661/ /pubmed/30261634 http://dx.doi.org/10.3390/s18103238 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Knoepp, Fenja Wahl, Joel Andersson, Anders Borg, Johan Weissmann, Norbert Ramser, Kerstin Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions |
title | Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions |
title_full | Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions |
title_fullStr | Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions |
title_full_unstemmed | Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions |
title_short | Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions |
title_sort | development of a gas-tight microfluidic system for raman sensing of single pulmonary arterial smooth muscle cells under normoxic/hypoxic conditions |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6210661/ https://www.ncbi.nlm.nih.gov/pubmed/30261634 http://dx.doi.org/10.3390/s18103238 |
work_keys_str_mv | AT knoeppfenja developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions AT wahljoel developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions AT anderssonanders developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions AT borgjohan developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions AT weissmannnorbert developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions AT ramserkerstin developmentofagastightmicrofluidicsystemforramansensingofsinglepulmonaryarterialsmoothmusclecellsundernormoxichypoxicconditions |