Real Time Polymerase Chain Reaction for Hepatitis B Screening in Donor Corneas in the Central Eye Bank of Iran

PURPOSE: The aim of this study was to report the results of the use of real-time polymerase chain reaction (PCR) for the diagnosis of hepatitis B virus (HBV) infection in cornea donors at the Central Eye Bank of Iran. METHODS: Between 2014 and 2016, all cornea donors that had negative screening sero...

Descripción completa

Detalles Bibliográficos
Autores principales: Samiee, Shahram, Kanavi, Mozhgan Rezaei, Javadi, Mohammad Ali, Bagheri, Abouzar, Balagholi, Sahar, Hashemi, Marzieh Sadat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6210878/
https://www.ncbi.nlm.nih.gov/pubmed/30479707
http://dx.doi.org/10.4103/jovr.jovr_157_17
Descripción
Sumario:PURPOSE: The aim of this study was to report the results of the use of real-time polymerase chain reaction (PCR) for the diagnosis of hepatitis B virus (HBV) infection in cornea donors at the Central Eye Bank of Iran. METHODS: Between 2014 and 2016, all cornea donors that had negative screening serologic results for hepatitis B (HB) surface antigen, HB surface antibody (Ab), hepatitis C virus Ab, human immune deficiency virus Ab, human T-cell leukemia virus Ab, and syphilis, and positive serology for HB core Ab were subjected to real-time PCR with a detection limit of 400 IU/mL to identify HBV DNA. Positive results for HBV DNA were considered occult HBV infections in these donors. RESULTS: Over the 3-year period, 122 out of 10448 cornea donors had negative screening serologic tests outside of HB core Ab. Of which, 90 cases were subjected to real-time PCR. Occult HBV was detected in 11 cases (12.2%), resulting in the rejection of the corresponding corneas. The remaining 79 cases (87.8%) had negative results for HBV DNA and the corresponding corneas were used for transplantation. CONCLUSION: Implementation of PCR for the detection of occult HBV in cornea donors is necessary to not only increase the security level of cornea donation but also minimize the rejection rate of donors that have isolated HB core Ab reactivity.