Cargando…

High-Resolution Seismocardiogram Acquisition and Analysis System

Several devices and measurement approaches have recently been developed to perform ballistocardiogram (BCG) and seismocardiogram (SCG) measurements. The development of a wireless acquisition system (hardware and software), incorporating a novel high-resolution micro-electro-mechanical system (MEMS)...

Descripción completa

Detalles Bibliográficos
Autores principales: Leitão, Fábio, Moreira, Eurico, Alves, Filipe, Lourenço, Mário, Azevedo, Olga, Gaspar, João, Rocha, Luis A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6211127/
https://www.ncbi.nlm.nih.gov/pubmed/30322147
http://dx.doi.org/10.3390/s18103441
_version_ 1783367275765563392
author Leitão, Fábio
Moreira, Eurico
Alves, Filipe
Lourenço, Mário
Azevedo, Olga
Gaspar, João
Rocha, Luis A.
author_facet Leitão, Fábio
Moreira, Eurico
Alves, Filipe
Lourenço, Mário
Azevedo, Olga
Gaspar, João
Rocha, Luis A.
author_sort Leitão, Fábio
collection PubMed
description Several devices and measurement approaches have recently been developed to perform ballistocardiogram (BCG) and seismocardiogram (SCG) measurements. The development of a wireless acquisition system (hardware and software), incorporating a novel high-resolution micro-electro-mechanical system (MEMS) accelerometer for SCG and BCG signals acquisition and data treatment is presented in this paper. A small accelerometer, with a sensitivity of up to 0.164 µs/µg and a noise density below 6.5 µg/ [Formula: see text] is presented and used in a wireless acquisition system for BCG and SCG measurement applications. The wireless acquisition system also incorporates electrocardiogram (ECG) signals acquisition, and the developed software enables the real-time acquisition and visualization of SCG and ECG signals (sensor positioned on chest). It then calculates metrics related to cardiac performance as well as the correlation of data from previously performed sessions with echocardiogram (ECHO) parameters. A preliminarily clinical study of over 22 subjects (including healthy subjects and cardiovascular patients) was performed to test the capability of the developed system. Data correlation between this measurement system and echocardiogram exams is also performed. The high resolution of the MEMS accelerometer used provides a better signal for SCG wave recognition, enabling a more consistent study of the diagnostic capability of this technique in clinical analysis.
format Online
Article
Text
id pubmed-6211127
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62111272018-11-14 High-Resolution Seismocardiogram Acquisition and Analysis System Leitão, Fábio Moreira, Eurico Alves, Filipe Lourenço, Mário Azevedo, Olga Gaspar, João Rocha, Luis A. Sensors (Basel) Article Several devices and measurement approaches have recently been developed to perform ballistocardiogram (BCG) and seismocardiogram (SCG) measurements. The development of a wireless acquisition system (hardware and software), incorporating a novel high-resolution micro-electro-mechanical system (MEMS) accelerometer for SCG and BCG signals acquisition and data treatment is presented in this paper. A small accelerometer, with a sensitivity of up to 0.164 µs/µg and a noise density below 6.5 µg/ [Formula: see text] is presented and used in a wireless acquisition system for BCG and SCG measurement applications. The wireless acquisition system also incorporates electrocardiogram (ECG) signals acquisition, and the developed software enables the real-time acquisition and visualization of SCG and ECG signals (sensor positioned on chest). It then calculates metrics related to cardiac performance as well as the correlation of data from previously performed sessions with echocardiogram (ECHO) parameters. A preliminarily clinical study of over 22 subjects (including healthy subjects and cardiovascular patients) was performed to test the capability of the developed system. Data correlation between this measurement system and echocardiogram exams is also performed. The high resolution of the MEMS accelerometer used provides a better signal for SCG wave recognition, enabling a more consistent study of the diagnostic capability of this technique in clinical analysis. MDPI 2018-10-13 /pmc/articles/PMC6211127/ /pubmed/30322147 http://dx.doi.org/10.3390/s18103441 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Leitão, Fábio
Moreira, Eurico
Alves, Filipe
Lourenço, Mário
Azevedo, Olga
Gaspar, João
Rocha, Luis A.
High-Resolution Seismocardiogram Acquisition and Analysis System
title High-Resolution Seismocardiogram Acquisition and Analysis System
title_full High-Resolution Seismocardiogram Acquisition and Analysis System
title_fullStr High-Resolution Seismocardiogram Acquisition and Analysis System
title_full_unstemmed High-Resolution Seismocardiogram Acquisition and Analysis System
title_short High-Resolution Seismocardiogram Acquisition and Analysis System
title_sort high-resolution seismocardiogram acquisition and analysis system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6211127/
https://www.ncbi.nlm.nih.gov/pubmed/30322147
http://dx.doi.org/10.3390/s18103441
work_keys_str_mv AT leitaofabio highresolutionseismocardiogramacquisitionandanalysissystem
AT moreiraeurico highresolutionseismocardiogramacquisitionandanalysissystem
AT alvesfilipe highresolutionseismocardiogramacquisitionandanalysissystem
AT lourencomario highresolutionseismocardiogramacquisitionandanalysissystem
AT azevedoolga highresolutionseismocardiogramacquisitionandanalysissystem
AT gasparjoao highresolutionseismocardiogramacquisitionandanalysissystem
AT rochaluisa highresolutionseismocardiogramacquisitionandanalysissystem