Cargando…
Classifying Adverse Events Following Lower Limb Orthopaedic Surgery in Children With Cerebral Palsy: Reliability of the Modified Clavien-Dindo System
BACKGROUND: The modified Clavien-Dindo (MCD) system is a reliable tool for classifying adverse events (AEs) in hip preservation surgery and has since been utilized in studies involving lower limb surgery for ambulant and nonambulant children with cerebral palsy (CP). However, the profile of AEs reco...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6211781/ https://www.ncbi.nlm.nih.gov/pubmed/30036291 http://dx.doi.org/10.1097/BPO.0000000000001233 |
_version_ | 1783367409461100544 |
---|---|
author | Zhou, Leena Willoughby, Kate Strobel, Natalie Thomason, Pam Gallagher, Charles Harambasic, Mela Khot, Abhay Graham, H. Kerr |
author_facet | Zhou, Leena Willoughby, Kate Strobel, Natalie Thomason, Pam Gallagher, Charles Harambasic, Mela Khot, Abhay Graham, H. Kerr |
author_sort | Zhou, Leena |
collection | PubMed |
description | BACKGROUND: The modified Clavien-Dindo (MCD) system is a reliable tool for classifying adverse events (AEs) in hip preservation surgery and has since been utilized in studies involving lower limb surgery for ambulant and nonambulant children with cerebral palsy (CP). However, the profile of AEs recorded in children with CP compared with typically developing children is different, and the reliability of the MCD in CP is unknown. This study aimed to evaluate the interrater and intrarater reliability of the MCD system for classifying AEs following lower limb surgery in children with CP. METHODS: Eighteen raters were invited to participate, including clinicians from surgical, nursing, and physical therapy professions, and individuals with CP. Following a MCD familiarization session, participants rated 40 clinical scenarios on 2 occasions, 2 weeks apart. Fleiss’ κ statistics were used to calculate interrater and intrarater reliability. RESULTS: The overall Fleiss’ κ value for interrater reliability in the first rating was 0.70 (95% confidence interval, 0.61-0.80), and increased to 0.75 (95% confidence interval, 0.66-0.84) in the second rating. The average Fleiss’ κ value for intrarater reliability was 0.78 (range, 0.48 to 1.00). Grading of more severe AEs (MCD III to V) achieved near perfect agreement (κ, 0.87 to 1.00). There was a lower level of agreement for minor AEs (MCD I-II) (κ, 0.53 to 0.55). A κ score of 0 to 0.2 was deemed as poor, 0.21 to 0.4 as fair, 0.41 to 0.6 as good, 0.61 to 0.8 as very good, and 0.81 to 1.0 as almost perfect agreement. CONCLUSIONS: The MCD System demonstrates a very good interrater and intrarater reliability following lower limb surgery in children with CP. The MCD can be used by clinicians from different health care professions with a high level of reliability. The MCD may improve standardization of AE recording with a view to accurate audits and improved clarity in outcome studies for CP. LEVEL OF EVIDENCE: Level II—diagnostic. |
format | Online Article Text |
id | pubmed-6211781 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-62117812018-11-21 Classifying Adverse Events Following Lower Limb Orthopaedic Surgery in Children With Cerebral Palsy: Reliability of the Modified Clavien-Dindo System Zhou, Leena Willoughby, Kate Strobel, Natalie Thomason, Pam Gallagher, Charles Harambasic, Mela Khot, Abhay Graham, H. Kerr J Pediatr Orthop Neuromuscular BACKGROUND: The modified Clavien-Dindo (MCD) system is a reliable tool for classifying adverse events (AEs) in hip preservation surgery and has since been utilized in studies involving lower limb surgery for ambulant and nonambulant children with cerebral palsy (CP). However, the profile of AEs recorded in children with CP compared with typically developing children is different, and the reliability of the MCD in CP is unknown. This study aimed to evaluate the interrater and intrarater reliability of the MCD system for classifying AEs following lower limb surgery in children with CP. METHODS: Eighteen raters were invited to participate, including clinicians from surgical, nursing, and physical therapy professions, and individuals with CP. Following a MCD familiarization session, participants rated 40 clinical scenarios on 2 occasions, 2 weeks apart. Fleiss’ κ statistics were used to calculate interrater and intrarater reliability. RESULTS: The overall Fleiss’ κ value for interrater reliability in the first rating was 0.70 (95% confidence interval, 0.61-0.80), and increased to 0.75 (95% confidence interval, 0.66-0.84) in the second rating. The average Fleiss’ κ value for intrarater reliability was 0.78 (range, 0.48 to 1.00). Grading of more severe AEs (MCD III to V) achieved near perfect agreement (κ, 0.87 to 1.00). There was a lower level of agreement for minor AEs (MCD I-II) (κ, 0.53 to 0.55). A κ score of 0 to 0.2 was deemed as poor, 0.21 to 0.4 as fair, 0.41 to 0.6 as good, 0.61 to 0.8 as very good, and 0.81 to 1.0 as almost perfect agreement. CONCLUSIONS: The MCD System demonstrates a very good interrater and intrarater reliability following lower limb surgery in children with CP. The MCD can be used by clinicians from different health care professions with a high level of reliability. The MCD may improve standardization of AE recording with a view to accurate audits and improved clarity in outcome studies for CP. LEVEL OF EVIDENCE: Level II—diagnostic. Lippincott Williams & Wilkins 2018 2018-08-21 /pmc/articles/PMC6211781/ /pubmed/30036291 http://dx.doi.org/10.1097/BPO.0000000000001233 Text en Copyright © 2018 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Neuromuscular Zhou, Leena Willoughby, Kate Strobel, Natalie Thomason, Pam Gallagher, Charles Harambasic, Mela Khot, Abhay Graham, H. Kerr Classifying Adverse Events Following Lower Limb Orthopaedic Surgery in Children With Cerebral Palsy: Reliability of the Modified Clavien-Dindo System |
title | Classifying Adverse Events Following Lower Limb Orthopaedic Surgery in Children With Cerebral Palsy: Reliability of the Modified Clavien-Dindo System |
title_full | Classifying Adverse Events Following Lower Limb Orthopaedic Surgery in Children With Cerebral Palsy: Reliability of the Modified Clavien-Dindo System |
title_fullStr | Classifying Adverse Events Following Lower Limb Orthopaedic Surgery in Children With Cerebral Palsy: Reliability of the Modified Clavien-Dindo System |
title_full_unstemmed | Classifying Adverse Events Following Lower Limb Orthopaedic Surgery in Children With Cerebral Palsy: Reliability of the Modified Clavien-Dindo System |
title_short | Classifying Adverse Events Following Lower Limb Orthopaedic Surgery in Children With Cerebral Palsy: Reliability of the Modified Clavien-Dindo System |
title_sort | classifying adverse events following lower limb orthopaedic surgery in children with cerebral palsy: reliability of the modified clavien-dindo system |
topic | Neuromuscular |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6211781/ https://www.ncbi.nlm.nih.gov/pubmed/30036291 http://dx.doi.org/10.1097/BPO.0000000000001233 |
work_keys_str_mv | AT zhouleena classifyingadverseeventsfollowinglowerlimborthopaedicsurgeryinchildrenwithcerebralpalsyreliabilityofthemodifiedclaviendindosystem AT willoughbykate classifyingadverseeventsfollowinglowerlimborthopaedicsurgeryinchildrenwithcerebralpalsyreliabilityofthemodifiedclaviendindosystem AT strobelnatalie classifyingadverseeventsfollowinglowerlimborthopaedicsurgeryinchildrenwithcerebralpalsyreliabilityofthemodifiedclaviendindosystem AT thomasonpam classifyingadverseeventsfollowinglowerlimborthopaedicsurgeryinchildrenwithcerebralpalsyreliabilityofthemodifiedclaviendindosystem AT gallaghercharles classifyingadverseeventsfollowinglowerlimborthopaedicsurgeryinchildrenwithcerebralpalsyreliabilityofthemodifiedclaviendindosystem AT harambasicmela classifyingadverseeventsfollowinglowerlimborthopaedicsurgeryinchildrenwithcerebralpalsyreliabilityofthemodifiedclaviendindosystem AT khotabhay classifyingadverseeventsfollowinglowerlimborthopaedicsurgeryinchildrenwithcerebralpalsyreliabilityofthemodifiedclaviendindosystem AT grahamhkerr classifyingadverseeventsfollowinglowerlimborthopaedicsurgeryinchildrenwithcerebralpalsyreliabilityofthemodifiedclaviendindosystem |